Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

EtherCAT Master / EtherNet/IP Slave

 

 

Document code: MN67E77_ENG     Revision 1.000   Page 1 of 28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English

 

 

EtherCAT Master / EtherNet/IP Slave - 
Converter

  

(Order Code:  HD67E77-A1) 

 

For Website information:  

www.adfweb.com?Product=HD67E77

   

 

For Price information: 

www.adfweb.com?Price=HD67E77-A1

 

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple Electrical isolation 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

For other EtherCAT Master products see also the following link: 

 

Converter EtherCAT Slave to  

www.adfweb.com?Product=HD67E50

       

(Serial) 

www.adfweb.com?Product=HD67E51

      

(Modbus Master) 

www.adfweb.com?Product=HD67E52

      

(Modbus Slave)

  

www.adfweb.com?Product=HD67E53

       

(Modbus TCP Master) 

www.adfweb.com?Product=HD67E54

       

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67E55

       

(BACnet Master) 

www.adfweb.com?Product=HD67E56

       

(BACnet Slave) 

www.adfweb.com?Product=HD67E57

       

(CAN) 

www.adfweb.com?Product=HD67E58

       

(CANopen) 

www.adfweb.com?Product=HD67E59

       

(DeviceNet Master) 

www.adfweb.com?Product=HD67E60

       

(DeviceNet Slave) 

www.adfweb.com?Product=HD67E61

       

(DMX) 

www.adfweb.com?Product=HD67E62

       

(Ethernet) 

www.adfweb.com?Product=HD67E64

       

(IEC61850 Client) 

www.adfweb.com?Product=HD67E65

       

(IEC61850 Server) 

www.adfweb.com?Product=HD67E66

       

(J1939) 

www.adfweb.com?Product=HD67E67

       

(MQTT) 

www.adfweb.com?Product=HD67E68

       

(NMEA0183) 

www.adfweb.com?Product=HD67E69

       

(NMEA2000) 

www.adfweb.com?Product=HD67E70

     

(OPC UA Client) 

www.adfweb.com?Product=HD67E71

       

(OPC UA Server) 

www.adfweb.com?Product=HD67E72

       

(PROFINET Master) 

www.adfweb.com?Product=HD67E73

       

(Modbus TCP Master) 

www.adfweb.com?Product=HD67E74

       

(SNMP Manager) 

www.adfweb.com?Product=HD67E75

       

(SNMP Agent) 

www.adfweb.com?Product=HD67E76

       

(EtherNet/IP Master) 

www.adfweb.com?Product=HD67E78

       

(S7comm Client) 

User Manual   

 

Summary of Contents for HD67E77-A1

Page 1: ...dbus TCP Slave www adfweb com Product HD67E55 BACnet Master www adfweb com Product HD67E56 BACnet Slave www adfweb com Product HD67E57 CAN www adfweb com Product HD67E58 CANopen www adfweb com Product...

Page 2: ...TECHNICAL SUPPORT 28 RETURN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to th...

Page 3: ...The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and oper...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Master EtherNet IP Slave Document code MN67E77_ENG Revision 1 000 Page 4 of 28 EXAMPLE OF CONNECTION...

Page 5: ...ustrial Electronic Devices ADFweb com S r l User Manual EtherCAT Master EtherNet IP Slave Document code MN67E77_ENG Revision 1 000 Page 5 of 28 CONNECTION SCHEME Figure 1 Connection scheme for HD67E77...

Page 6: ...ween EtherCAT EtherNet IP Power Supply Two directional information between EtherCAT bus and EtherNet IP bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperat...

Page 7: ...MN67E77_ENG Revision 1 000 Page 7 of 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumpt...

Page 8: ...ng on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is u...

Page 9: ...en Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 EtherNet IP comm green It blinks when EtherNet IP communication is running Blinks quickly Boot state Blinks...

Page 10: ...he EtherCAT slave devices read the data addressed to them while the telegram passes through the device processing data on the fly In other words real time data and messages are prioritized over more g...

Page 11: ...that runs with Windows called SW67E77 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software prese...

Page 12: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Master EtherNet IP Slave Converter in order to configure another device in th...

Page 13: ...ange the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possi...

Page 14: ...Master EtherNet IP Slave Document code MN67E77_ENG Revision 1 000 Page 14 of 28 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation ins...

Page 15: ...DNS protocol is enabled In the field Primary DNS the IP Address of the primary DNS server is defined In the field Secondary DNS the IP Address of the secondary DNS server is defined The means of the f...

Page 16: ...CAT slave devices to connect and the parameters to read write Below the EtherCAT Master Devices List the list of the EtherCAT devices to connect is defined It is possible to import the slaves using th...

Page 17: ...SI file PROCESS DATA The means of the fields are In the field Slot the selected Slot is defined In the field Name the name of the variable is defined In the field Type the format of the EtherCAT varia...

Page 18: ...erNet IP array where the read value of the variable is mapped is defined In the field Start Bit R the starting bit of the selected Position where the variable is mapped is defined In the field Time Re...

Page 19: ...Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put D...

Page 20: ...the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to prog...

Page 21: ...commissioning of the EtherNet IP Converter as described on the following pages was accomplished with the help of the RSLogix 5000 software of Rockwell Automation In case of using a control system fro...

Page 22: ...5 For the Comm Format Data SINT shall be selected as the data type RSLogix 5000 requires a configuration assembly instance Both modules do not provide a configuration assembly instance Therefore it is...

Page 23: ...l Electronic Devices ADFweb com S r l User Manual EtherCAT Master EtherNet IP Slave Document code MN67E77_ENG Revision 1 000 Page 23 of 28 4 After the configuration is completed the controller tags ar...

Page 24: ...herNet IP Slave Document code MN67E77_ENG Revision 1 000 Page 24 of 28 5 With RSLinks Classic Lite after have done a network scan RSWho and finding the EtherNet IP device it is possible to load the ED...

Page 25: ...Electronic Devices ADFweb com S r l User Manual EtherCAT Master EtherNet IP Slave Document code MN67E77_ENG Revision 1 000 Page 25 of 28 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for...

Page 26: ...bination of the following HD67E77 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E77 EtherCAT Master EtherNet IP Slave Converter Order C...

Page 27: ...llection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Page 28: ...ease do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the produ...

Reviews: