ADF Web HD67E23-A1 User Manual Download Page 26

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

EtherCAT Slave / PROFINET Slave

 

 

Document code: MN67E23_ENG     Revision 1.000   Page 26 of 28

 

 

 
ORDERING INFORMATIONS: 

 
The ordering part number is formed by a valid combination of the following:  

HD67E23 – xx 

 

Connectors Type 

1: Removable 5mm Screw Terminal 

 
 

 

 

 

Enclosure Type 

A: 1M, 35mm DIN Rail mounting 

 

 

Device Family 

 

 

 

 

HD67E23: EtherCAT Slave / PROFINET Slave - Converter 

 
 

Order Code: 

HD67E23-A1 

 

-  

EtherCAT Slave / PROFINET Slave – Converter 

 

 
 

ACCESSORIES: 

 
Order Code:  

AC34011 

-  

35mm

 

Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC  

Order Code:  

AC34012 

35mm

 

Rail DIN - Power Supply 220/240V AC 50/60Hz – 24 V DC 

Summary of Contents for HD67E23-A1

Page 1: ...Product HD67E05 BACnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Master www...

Page 2: ...DARDS 27 WARRANTIES AND TECHNICAL SUPPORT 28 RETURN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document i...

Page 3: ...e device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operat...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave PROFINET Slave Document code MN67E23_ENG Revision 1 000 Page 4 of 28 EXAMPLE OF CONNECTION...

Page 5: ...ndustrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave PROFINET Slave Document code MN67E23_ENG Revision 1 000 Page 5 of 28 CONNECTION SCHEME Figure 1 Connection scheme for HD67E23 A...

Page 6: ...nformation between EtherCAT bus and PROFINET bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compo...

Page 7: ...N67E23_ENG Revision 1 000 Page 7 of 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumptio...

Page 8: ...on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is use...

Page 9: ...PROFINET comm green It blinks when PROFINET communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 Error state green ON An error in the communication busses o...

Page 10: ...the standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them whil...

Page 11: ...ust be made using Connector9 and or Connector10 of the HD67E23 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms re...

Page 12: ...hat runs with Windows called SW67E23 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Page 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave PROFINET Slave Converter in order to configure another device in the sa...

Page 14: ...ge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possibl...

Page 15: ...AT Slave PROFINET Slave Document code MN67E23_ENG Revision 1 000 Page 15 of 28 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insid...

Page 16: ...for PROFINET are In the fields IP Address the IP address for PROFINET side of the converter is defined In the fields SubNet Mask the SubNet Mask for PROFINET side of the converter is defined In the f...

Page 17: ...the EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT variab...

Page 18: ...riable is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherCAT...

Page 19: ...By pressing the PROFINET XML button it is possible to save the GSDML file for the PROFINET side of the converter The GSDML file is used to configure the PROFINET Master ETHERCAT ESI FILE By pressing t...

Page 20: ...thernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip...

Page 21: ...he program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to progra...

Page 22: ...r PROFINET The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal V12 software by Siemens In the case of usi...

Page 23: ...web com S r l User Manual EtherCAT Slave PROFINET Slave Document code MN67E23_ENG Revision 1 000 Page 23 of 28 2 Import the module in the network connect the device to the PLC network and edit the par...

Page 24: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave PROFINET Slave Document code MN67E23_ENG Revision 1 000 Page 24 of 28 3 Load the configuration into the PLC...

Page 25: ...l Electronic Devices ADFweb com S r l User Manual EtherCAT Slave PROFINET Slave Document code MN67E23_ENG Revision 1 000 Page 25 of 28 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for H...

Page 26: ...ombination of the following HD67E23 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E23 EtherCAT Slave PROFINET Slave Converter Order Cod...

Page 27: ...ection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the r...

Page 28: ...se do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Reviews: