POWER SUPPLY: 

 
The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. 
 

VAC 

 

VDC 

 

Vmin 

Vmax 

Vmin 

Vmax 

8V 

24V 

12V 

35V 

 
 
 

 

 

 

Consumption at 24V DC: 

Device 

Consumption [W/VA] 

HD67E18-x-A1 

3.5 

 
 
 
  
 

HD67E18-x-A1 

Caution:  Do not reverse the polarity power

 

Summary of Contents for HD67E18-2-A1

Page 1: ...www adfweb com Product HD67E05 BACnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 Devic...

Page 2: ...WARRANTIES AND TECHNICAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated...

Page 3: ...evice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave NMEA0183 Document code MN67E18_ENG Revision 1 000 Page 4 of 30 EXAMPLE OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave NMEA0183 Document code MN67E18_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1a Connection scheme for HD67E18 2 A1...

Page 6: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave NMEA0183 Document code MN67E18_ENG Revision 1 000 Page 6 of 30 Figure 1b Connection scheme for HD67E18 5 A1...

Page 7: ...formation between EtherCAT bus and NMEA0183 bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compos...

Page 8: ...8_ENG Revision 1 000 Page 8 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Page 9: ...the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used f...

Page 10: ...s quickly Boot state Blinks very slowly 0 5Hz update in progress 3 EtherCAT comm green It blinks when EtherCAT communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in pro...

Page 11: ...standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them while t...

Page 12: ...nt code MN67E18_ENG Revision 1 000 Page 12 of 30 RS232 The connection from RS232 socket to a serial port example one from a personal computer must be made with a NULL MODEM cable a serial cable where...

Page 13: ...dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 8...

Page 14: ...made using Connector8 of the HD67E18 x A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections i...

Page 15: ...uns with Windows called SW67E18 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on o...

Page 16: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave NMEA0183 Converter in order to configure another device in the same man...

Page 17: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible t...

Page 18: ...erCAT Slave NMEA0183 Document code MN67E18_ENG Revision 1 000 Page 18 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside t...

Page 19: ...cked DNS protocol is enabled In the field Primary DNS the IP Address of the primary DNS server is defined In the field Secondary DNS the IP Address of the secondary DNS server is defined The means of...

Page 20: ...t code MN67E18_ENG Revision 1 000 Page 20 of 30 The means of the fields for Serial are In the field Baudrate the baudrate for the serial line is defined In the field Parity the parity of the serial li...

Page 21: ...nable is checked the NMEA 0183 sentence is enabled In the field Sentence the NMEA 0183 sentence is defined In the field Index the Index of the NMEA 0183 sentence is defined In the field Data Field the...

Page 22: ...EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT variable...

Page 23: ...rCAT Slave NMEA0183 Document code MN67E18_ENG Revision 1 000 Page 23 of 30 ETHERCAT ESI FILE By pressing the EtherCAT ESI File button it is possible to save the ESI file for the EtherCAT side of the c...

Page 24: ...rnet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 o...

Page 25: ...gram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 11 make sure that you have the administrator privileges In case you have to program m...

Page 26: ...al Electronic Devices ADFweb com S r l User Manual EtherCAT Slave NMEA0183 Document code MN67E18_ENG Revision 1 000 Page 26 of 30 MECHANICAL DIMENSIONS Figure 8a Mechanical dimensions scheme for HD67E...

Page 27: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave NMEA0183 Document code MN67E18_ENG Revision 1 000 Page 27 of 30 Figure 8b Mechanical dimensions scheme for HD67E18 5 A1...

Page 28: ...ors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Modbus port 2 RS232 5 RS485 Device Family HD67E18 EtherCAT Slave NMEA0183 Converter Order Code HD67E18 2 A1 EtherCAT...

Page 29: ...ion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recy...

Page 30: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Reviews: