Note: 
    When you receive the device, for the first time, you also have to update the Firmware in the HD67E11 device. 

 

 

Warning: 
    If  Fig.  8  appears  when  you  try  to  do  the  Update  try  these  points  before  seeking 

assistance: 

 

Try to repeat the operations for the updating; 

 

Try with another PC; 

 

Try to restart the PC; 

 

Check the LAN settings; 

 

If  you  are  using  the  program  inside  a  Virtual  Machine,  try  to  use  in  the  main 

Operating System; 

 

If  you  are  using  Windows  Seven,  Vista,  8  or  10,  11  make  sure  that  you  have  the 
administrator privileges; 

 

In  case  you  have  to  program  more  than  one  device,  using  the  "UDP  Update",  you 
have to cancel the ARP table every time you connect a new device on Ethernet. For 
do  this  you  have  to launch  the  "Command  Prompt"  and  write  the  command  "arp  -
d". Pay attention that with Windows Vista, Seven, 8, 10, 11 you have to launch the 
"Command Prompt" with Administrator Rights; 

 

Pay attention at Firewall lock. 

 
Warning: 

    In the case of HD67E11 you have to use the software “HD67E11”: 

www.adfweb.com\download\filefold\SW67E11.zip

.

Figure 8: “Error” window

 

Summary of Contents for HD67E11-A1

Page 1: ...Cnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Master www adfweb com Product...

Page 2: ...ND TECHNICAL SUPPORT 27 RETURN POLICY 27 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to...

Page 3: ...ice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation o...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DMX Document code MN67E11_ENG Revision 1 001 Page 4 of 27 EXAMPLE OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DMX Document code MN67E11_ENG Revision 1 001 Page 5 of 27 CONNECTION SCHEME Figure 1b Connection scheme for HD67E11 A1...

Page 6: ...ply Two directional information between EtherCAT bus and DMX bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATIO...

Page 7: ...1_ENG Revision 1 001 Page 7 of 27 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Page 8: ...he position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for...

Page 9: ...Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 DMX comm green It blinks when a DMX message is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4...

Page 10: ...andard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them while the...

Page 11: ...p 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 828...

Page 12: ...ade using Connector8 of the HD67E11 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in ca...

Page 13: ...s with Windows called SW67E11 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on our...

Page 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave DMX Converter in order to configure another device in the same manner i...

Page 15: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to c...

Page 16: ...EtherCAT Slave DMX Document code MN67E11_ENG Revision 1 001 Page 16 of 27 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the...

Page 17: ...s checked DNS protocol is enabled In the field Primary DNS the IP Address of the primary DNS server is defined In the field Secondary DNS the IP Address of the secondary DNS server is defined The mean...

Page 18: ...hernet are In the fields IP Address the IP address for Ethernet side of the converter is defined In the fields SubNet Mask the SubNet Mask for Ethernet side of the converter is defined In the fields G...

Page 19: ...the main window for SW67E11 Fig 2 the window EtherCAT Slave Set Group appears Fig 4 This section is used to define the EtherCAT group in which saving the variables configured into the EEPROM of the c...

Page 20: ...d Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the...

Page 21: ...ow for SW67E11 Fig 2 the DMX Default Value window appears Fig 6 In this section it is possible to define the default value for each channel of the DMX array when the converter is turned ON ETHERCAT ES...

Page 22: ...t cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of D...

Page 23: ...am inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 11 make sure that you have the administrator privileges In case you have to program mor...

Page 24: ...strial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DMX Document code MN67E11_ENG Revision 1 001 Page 24 of 27 MECHANICAL DIMENSIONS Figure 9 Mechanical dimensions scheme for HD67E11...

Page 25: ...d combination of the following HD67E11 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E11 EtherCAT Slave DMX Converter Order Code HD67E1...

Page 26: ...n systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycl...

Page 27: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to th...

Reviews: