ORDERING INFORMATIONS: 

 
The ordering part number is formed by a valid combination of the following:  

HD67E09 – xx 

 

Connectors Type 

1: Removable 5mm Screw Terminal 

 
 

 

 

 

Enclosure Type 

A: 1M, 35mm DIN Rail mounting 

 

 

Device Family 

 

 

 

 

HD67E09: EtherCAT Slave / DeviceNet Master - Converter 

 
 

Order Code: 

HD67E09-A1 

 

-  

EtherCAT Slave / DeviceNet Master – Converter 

 

 
 

ACCESSORIES: 

 
Order Code:  

AC34011 

-  

35mm

 

Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC  

Order Code:  

AC34012 

35mm

 

Rail DIN - Power Supply 220/240V AC 50/60Hz – 24 V DC 

Summary of Contents for HD67E09-A1

Page 1: ...b com Product HD67E05 BACnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E07 CAN www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E10 DeviceNet Slave...

Page 2: ...UPPORT 26 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain t...

Page 3: ...he device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and opera...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DeviceNet Master Document code MN67E09_ENG Revision 1 000 Page 4 of 26 EXAMPLE OF CONNECTION...

Page 5: ...dustrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DeviceNet Master Document code MN67E09_ENG Revision 1 000 Page 5 of 26 CONNECTION SCHEME Figure 1 Connection scheme for HD67E09...

Page 6: ...onal information between EtherCAT bus and DeviceNet bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You nee...

Page 7: ...MN67E09_ENG Revision 1 000 Page 7 of 26 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumpti...

Page 8: ...g on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is us...

Page 9: ...Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 DeviceNet comm green It blinks when a DeviceNet message is received Blinks quickly Boot state Blinks very slowly 0 5Hz update i...

Page 10: ...the standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them whi...

Page 11: ...st be made using Connector8 of the HD67E09 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connection...

Page 12: ...that runs with Windows called SW67E09 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software presen...

Page 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave DeviceNet Master Converter in order to configure another device in the...

Page 14: ...nge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possib...

Page 15: ...T Slave DeviceNet Master Document code MN67E09_ENG Revision 1 000 Page 15 of 26 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insi...

Page 16: ...fined In the field Node Address the ID of the converter is defined The means of the fields for the DeviceNet Master section are In the field ID Device the address for the DeviceNet Master is defined I...

Page 17: ...the EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT varia...

Page 18: ...ariable is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherCA...

Page 19: ...viceNet Network appears Fig 5 The data of the columns have the following meanings In the field ID the ID of a slave DeviceNet device is defined In the field N BYTE IN the number of input byte of the s...

Page 20: ...t Network step The data of the column have the following meanings Byte IN side In the column Offset it is possible to select the desired byte of DeviceNet which will be written from the EtherCAT Maste...

Page 21: ...Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Di...

Page 22: ...the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to progr...

Page 23: ...Electronic Devices ADFweb com S r l User Manual EtherCAT Slave DeviceNet Master Document code MN67E09_ENG Revision 1 000 Page 23 of 26 MECHANICAL DIMENSIONS Figure 9 Mechanical dimensions scheme for...

Page 24: ...mbination of the following HD67E09 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E09 EtherCAT Slave DeviceNet Master Converter Order Co...

Page 25: ...lection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the...

Page 26: ...ase do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the produc...

Reviews: