background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

User Manual   

LoRaWAN / OPC UA Client

 

 

Document code: MN67D37_ENG     Revision 1.000   Page 6 of 32

 

 

 

CHARACTERISTICS:

 

 

The HD67D37-B2 is a LoRaWAN / OPC UA Client Converter. 

 

It allows the following characteristics: 

 

Electrical isolation between OPC UA Client and Power Supply; 

 

Two-directional information between LoRaWAN bus and OPC UA bus; 

 

Mountable on 35mm Rail DIN; 

 

Wide power supply input range: 12…35V DC and 8…24V AC; 

 

Wide temperature range:  -40°C / 85°C [-40°F / +185°F]. 

 
 
CONFIGURATION: 
 

You need Compositor SW67D37 software on your PC in order to perform the following: 

 

Define the parameter of LoRaWAN line; 

 

Define the parameter of OPC UA line; 

 

Define the list of LoRaWAN messages in uplink and downlink to the LoRaWAN gateway; 

 

Define the list of OPC UA servers connected to the converter; 

 

Update the device. 

Summary of Contents for HD67D37-B2-868MHz

Page 1: ...aster www adfweb com Product HD67D17 BACnet Slave www adfweb com Product HD67D18 Ethernet www adfweb com Product HD67D19 CAN www adfweb com Product HD67D20 CANopen www adfweb com Product HD67D21 Devic...

Page 2: ...ECHNICAL SUPPORT 32 RETURN POLICY 32 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the...

Page 3: ...vice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual LoRaWAN OPC UA Client Document code MN67D37_ENG Revision 1 000 Page 4 of 32 EXAMPLE OF CONNECTION...

Page 5: ...ndustrial Electronic Devices ADFweb com S r l User Manual LoRaWAN OPC UA Client Document code MN67D37_ENG Revision 1 000 Page 5 of 32 CONNECTION SCHEME Figure 1 Connection scheme for HD67D37 B2 xxxMHz...

Page 6: ...ectional information between LoRaWAN bus and OPC UA bus Mountable on 35mm Rail DIN Wide power supply input range 12 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You ne...

Page 7: ...G Revision 1 000 Page 7 of 32 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V...

Page 8: ...the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used f...

Page 9: ...reen Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 LoRaWAN communication yellow Blinks when LoRaWAN data is received Blinks quickly Boot state Blinks very s...

Page 10: ...r of stars topology in which gateways relay messages between end devices and a central network server The wireless communication takes advantage of the Long Range characteristics of the LoRa physical...

Page 11: ...communication The Ethernet connection must be made using Connector2 of HD67D37 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to t...

Page 12: ...Converter use the available software that runs with Windows called SW67D37 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Wind...

Page 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable LoRaWAN OPC UA Client Converter in order to configure another device in the same manne...

Page 14: ...he language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to...

Page 15: ...RaWAN OPC UA Client Document code MN67D37_ENG Revision 1 000 Page 15 of 32 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside th...

Page 16: ...ation is defined In the field Transmission Type the type of LoRaWAN communication is defined In the field Max Payload Size the maximum dimension of the LoRaWAN messages is defined fixed in relation to...

Page 17: ...fined In the field GATEWAY the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field DNS...

Page 18: ...data to OPC UA LORAWAN UPLINK The means of the fields are If the field Enable is checked the LoRaWAN message is enabled In the field Start Byte the starting byte of the internal memory array where ta...

Page 19: ...AN DOWNLINK The means of the fields are If the field Enable is checked the LoRaWAN message is enabled In the field Start Byte the starting byte of the internal memory array where placing the data is d...

Page 20: ...re 5a EtherCAT Slave Set Access Master To Slave window Figure 5 OPC UA Client Access window OPC UA CLIENT ACCESS By Pressing the OPC UA Client Access button from the main window for SW67D37 Fig 2 the...

Page 21: ...r window Figure 7 Modify OPC UA Server window By clicking on Add it is possible to add a new OPC UA Server inserting its characteristics Server Address Authorization Security Type The window Add OPC U...

Page 22: ...t is possible to get the list of available variables from the selected Server The window Scan Server OPC UA appears Fig 8 The means of the checkboxes inside the table are If the field Read is checked...

Page 23: ...the OPC UA variable is enabled In the field Display name the name of the OPC UA variable is defined In the field Node Type the type of the OPC UA node which includes the variable is defined In the fie...

Page 24: ...e of the OPC UA node which includes the variable is defined In the field Node ID the name of the OPC UA node which includes the variable is defined In the field Var Type the data format of the OPC UA...

Page 25: ...nal memory arrays where getting the value is defined In the field Mnemonic a description of the variable is defined Note By clicking on Auto Pos the position of the internal memory arrays where saving...

Page 26: ...et cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of...

Page 27: ...rogram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program mo...

Page 28: ...N Access section of SW67D37 Example 1 the converter is sending a LoRaWAN message related to row 4 of LoRaWAN Access LoRaWAN Uplink table of LoRaWAN Access section of SW67D37 with a Num Byte set of 4 T...

Page 29: ...rial Electronic Devices ADFweb com S r l User Manual LoRaWAN OPC UA Client Document code MN67D37_ENG Revision 1 000 Page 29 of 32 Figure 12 Mechanical dimensions scheme for HD67D37 B2 MECHANICAL DIMEN...

Page 30: ...HD67D37 B 2 xxxMHz Frequency for LoRaWAN communication 868 868 MHz Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67D37 LoRaWAN OPC UA Clien...

Page 31: ...on systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recyc...

Page 32: ...o the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Reviews: