PROFINET Master / MQTT 

 

Document code: MN67B80_ENG     Revision 1.000    Page 22 of 32

 

 

The means of the fields below are: 

 

In the field “

Name of Station

” is checked, the name of the PROFINET slave is defined; 

 

In the field “

IP Address

” the IP Address of the PROFINET slave is defined; 

 

In the field “

Update Time [ms]

” the delay used for IO communication is defined; 

 

In the field “

Answer TimeOut

” the allowed number of cycles without response from the slave is defined. 

 

Warning: 
The  data  from/to  the  slaves  are  mapped  consecutively  into  the  IN/OUT  PROFINET  arrays,  following  the  order  with  which  they  are 

defined. 

Summary of Contents for HD67B80-B2

Page 1: ...to www adfweb com Product HD67B45 OPC UA Server www adfweb com Product HD67B70 Serial www adfweb com Product HD67B71 Modbus Slave www adfweb com Product HD67B72 PROFIBUS Slave www adfweb com Product H...

Page 2: ...RDS 31 WARRANTIES AND TECHNICAL SUPPORT 32 RETURN POLICY 32 Pagina 2 di 32 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the followi...

Page 3: ...s etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assem...

Page 4: ...Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET Master MQTT Document code MN67B80_ENG Revision 1 000 Page 4 of 32 EXAMPLE OF C...

Page 5: ...ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET Master MQTT Document code MN67B80_ENG Revision 1 000 Page 5 of 32 Figure 1 Connection scheme for...

Page 6: ...bytes in reading and 1500 bytes in writing Two directional information between PROFINET and MQTT Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range...

Page 7: ...Master MQTT Document code MN67B80_ENG Revision 1 000 Page 7 of 32 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax V...

Page 8: ...ice has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second with Di...

Page 9: ...Boot state Blinks very slowly 0 5Hz update in progress 2 MQTT comm yellow Flashing MQTT message received OFF No MQTT messages Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 P...

Page 10: ...he Ethernet connection must be made using Connector3 of HD67B80 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms r...

Page 11: ...se the available software that runs with Windows called SW67B80 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last vers...

Page 12: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable PROFINET Master MQTT Converter in order to configure a...

Page 13: ...e is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Conn...

Page 14: ...e 39 0438 30 91 31 User Manual PROFINET Master MQTT Document code MN67B80_ENG Revision 1 000 Page 14 of 32 In the section Software Settings it is possible to enable disable some keyboard s commands fo...

Page 15: ...Page 15 of 32 SET COMMUNICATION By Pressing the Set Communication button from the main window for SW67B80 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections i...

Page 16: ...ne the main parameters of MQTT line The means of the fields are In the field Server URL the URL or the IP Address of the MQTT Server is defined In the field Server Port the port used for MQTT communic...

Page 17: ...efined In the field Username the username for the connection to the MQTT server is defined In the field Password the password for the connection to the MQTT server is defined ETHERNET This section is...

Page 18: ...for going out of the net In the field DNS the DNS address is defined This field is required if the server address is define by URL and not IP Address In the field Port the port used for MQTT communica...

Page 19: ...This field is required if the server address is define by URL and not IP Address In the field Port the port used for MQTT communication is defined In the field SSID the name of the Wi Fi network to c...

Page 20: ...67B80_ENG Revision 1 000 Page 20 of 32 Figure 3h Set Communication NTP window NTP NETWORK TIME PROTOCOL This section is used to define the parameters of NTP protocol The means of the fields are In the...

Page 21: ...Present in Network window PROFINET ACCESS By Pressing the PROFINET Access button from the main window for SW67B80 Fig 2 the window Definition of PROFINET Devices Present in Network appears Fig 4 This...

Page 22: ...of Station is checked the name of the PROFINET slave is defined In the field IP Address the IP Address of the PROFINET slave is defined In the field Update Time ms the delay used for IO communication...

Page 23: ...of PROFINET Device appears Fig 5 In the main table it is possible to import the Modules of the PROFINET device in use In the properties below it is possible to set the parameters of the slave These op...

Page 24: ...retained flag is enabled The MQTT server will hold the last topic published In the field QoS the QoS level is defined In the field Data Type the type of data to use is defined In the field Dimension t...

Page 25: ...defined the retained flag is enabled The MQTT server will hold the last topic published In the field QoS the QoS level is defined In the field Data Type the type of data to use is defined In the fiel...

Page 26: ...ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK...

Page 27: ...settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privilege...

Page 28: ...e MQTT messages The template is necessary in order to define the structure of the payload of the MQTT message and the info contained It is possible to have a simple text format or a JSON format The de...

Page 29: ...com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET Master MQTT Document code MN67B80_ENG Revision 1 000 Page 29 of 32 MECHANICAL DIMENSIONS Figure 9 Mechani...

Page 30: ...g part number is formed by a valid combination of the following HD67B80 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67B80 PROFINET Ma...

Page 31: ...countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicabl...

Page 32: ...exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about t...

Reviews: