User Manual   

OPC UA Client / BACnet Slave 

 

Document code: MN67B11_ENG     Revision 1.002    Page 18 of 33

 

Figure 3c: “Set Communication 

 BACnet Slave” 

window 

 

OPC

 

UA

 

C

LIENT

 
The means of the fields for “OPC UA Client” are: 

 

In the fields “

IP Address

” the IP address for OPC UA side of the converter is 

defined;

 

 

 

In  the  fields  “

SubNet

 

Mask

”  the  SubNet  Mask  for  OPC  UA  side  of  the 

converter is defined; 

 

In  the  fields  “

Gateway

”  the  default  gateway  of  the  net  is  defined.  This 

feature can be enabled or disabled pressing the Check Box field. This feature 
is used for going out of the net; 

 

In the field “

DNS

” the IP Address of the DNS server is defined. This feature 

can be enabled or disabled pressing the Check Box field. 

 

BAC

NET 

S

LAVE 

(

FOR 

BAC

NET

/IP): 

 

This section is used to define the main parameters of BACnet/IP line. The means of 
the fields are:

 

  

 

the fields “

IP ADDRESS

” the IP address  of BACnet/IP side of the converter 

is defined; 

 

In  the  fields  “

SUBNET

 

Mask

”  the  SubNet  Mask  of  BACnet/IP  side  of  the 

converter is defined; 

 

In the fields “

GATEWAY

” the default gateway of the network is defined. This 

feature can be enabled or disabled pressing the Check Box field. This feature 
is used for going out of the net; 

 

In  the  field  “

Port

”  the  port  used  for  BACnet  communication  is  defined.  The 

default  port  used  for  BACnet  communication  is  47808,  but  is  possible  to 
insert any value; 

 

In  the  field  "

BACnet  Device  Name

"  the  name  of  BACnet/IP  side  of  the 

converter is defined; 

 

In the field “

Device Identifier

” the ID of BACnet/IP side of the converter is 

defined; 

 

If the field “

BACnet description up to 32 chars

” is checked, the description of the BACnet objects can be up to 32 chars. 

Figure 3b: “Set Communication 

 OPC UA Client” 

window

 

Summary of Contents for HD67B11-IP-B2

Page 1: ...the following links OPC UA Client from to www adfweb com Product HD67B08 Serial www adfweb com Product HD67B09 Modbus Slave www adfweb com Product HD67B10 Modbus TCP Slave www adfweb com Product HD67B...

Page 2: ...33 RETURN POLICY 33 Pagina 2 di 33 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the p...

Page 3: ...ocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation as...

Page 4: ...ectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client BACnet Slave Document code MN67B11_ENG Revision 1 002 Page 4 of 33 EXAMPLE O...

Page 5: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client BACnet Slave Document code MN67B11_ENG Revision 1 002 Page 5 of 33 CONNECTION SCHEME Figure 1a Co...

Page 6: ...ces ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client BACnet Slave Document code MN67B11_ENG Revision 1 002 Page 6 of 33 Figure 1b Connection s...

Page 7: ...1500 bytes in reading and 1500 bytes in writing Two directional information between BACnet and OPC UA Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature ra...

Page 8: ...et Slave Document code MN67B11_ENG Revision 1 002 Page 8 of 33 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin...

Page 9: ...device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second with...

Page 10: ...oot state Blinks very slowly 0 5Hz update in progress 2 OPC UA comm yellow Flashing OPC UA response OFF No OPC UA response Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 BACne...

Page 11: ...h a 120 resistor it is necessary to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs cond...

Page 12: ...The Ethernet connection must be made using Connector3 of HD67B11 xxx B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 no...

Page 13: ...r use the available software that runs with Windows called SW67B11 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last v...

Page 14: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Client BACnet Slave Converter in order to confi...

Page 15: ...here is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section C...

Page 16: ...9 0438 30 91 31 User Manual OPC UA Client BACnet Slave Document code MN67B11_ENG Revision 1 002 Page 16 of 33 In the section Software Settings it is possible to enable disable some keyboard s commands...

Page 17: ...ION This section define the fundamental communication parameters of two buses OPC UA Client and Modbus TCP By Pressing the Set Communication button from the main window for SW67B11 Fig 2 the window Se...

Page 18: ...x field BACNET SLAVE FOR BACNET IP This section is used to define the main parameters of BACnet IP line The means of the fields are the fields IP ADDRESS the IP address of BACnet IP side of the conver...

Page 19: ...AC Address the MAC of BACnet node from 0 to 254 is defined The field Max Master specifies the highest allowable address for master nodes The value shall be less than or equal to 127 The field Max Info...

Page 20: ...t Slave Document code MN67B11_ENG Revision 1 002 Page 20 of 33 Figure 4 OPC UA Client Access window OPC UA ACCESS By Pressing the OPC UA Client Access button from the main window for SW67B11 Fig 2 the...

Page 21: ...2 Page 21 of 33 Figure 5 Add OPC UA Server Figure 6 Modify OPC UA Server By clicking on Add it is possible to add a new OPC UA Server inserting its characteristics Server Address Authorization Securit...

Page 22: ...PC UA window By clicking on Scan it is possible to get the list of available variables from the selected Server The window Scan Server OPC UA appears Fig 7 The means of the checkboxes inside the table...

Page 23: ...elds are If the field Enable is checked the OPC UA variable is enabled In the field Display name the name of the OPC UA variable is defined In the field Node Type the type of the OPC UA node which inc...

Page 24: ...defined In the field Node Type the type of the OPC UA node which includes the variable is defined In the field Node ID the name of the OPC UA node which includes the variable is defined In the field...

Page 25: ...tion the starting byte of the internal memory arrays where getting the value is defined In the field Mnemonic a description of the variable is defined Note By clicking on Auto Pos the position of the...

Page 26: ...cribed and BACnet in Write that contains the BACnet objects writeable by a BACnet Master the MQTT messages published The meaning of the fields in the window are the follows In the field Data Type is p...

Page 27: ...he Unit using its unique number by compiling the Selected BACnet Engineering Unit field or by selecting with the fields Select the Type and Select unit the Type Unit desired If the second way is used...

Page 28: ...rn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are...

Page 29: ...C Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that...

Page 30: ...rl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Client BACnet Slave Document code MN67B11_ENG Revision 1 002 Page 30 of 33 MECHANICAL DIMENSIONS Figure 14 Mecha...

Page 31: ...D67B11 xxx B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 2M 35mm DIN Rail mounting BACnet Type IP BACnet IP MSTP BACnet MS TP Device Family HD67B10 OPC UA Client BACnet Slave Co...

Page 32: ...an countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applic...

Page 33: ...to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information abou...

Reviews: