ADF Web HD67879-A1-XX User Manual Download Page 4

   

Industrial

 

Electronic Devices 

 

 

ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

User Manual   

IO-Link Master / EtherCAT Slave 

 

Document code: MN67879_ENG     Revision 1.000    Page 4 of 44

 

 

 
EXAMPLE OF CONNECTION:  

 

 
 

Summary of Contents for HD67879-A1-XX

Page 1: ...eb com Product HD67860 Modbus Master www adfweb com Product HD67861 Modbus Slave www adfweb com Product HD67862 Modbus TCP Master www adfweb com Product HD67864 Modbus TCP Slave www adfweb com Product...

Page 2: ...TIONS AND STANDARDS 43 WARRANTIES AND TECHNICAL SUPPORT 44 RETURN POLICY 44 Pagina 2 di 44 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check...

Page 3: ...locks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation a...

Page 4: ...ctronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 4 of 44 EXAMPLE...

Page 5: ...b com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 5 of 44 CONNECTION SCHEME Figure 1a...

Page 6: ...ces ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 6 of 44 Figure 1b Connectio...

Page 7: ...ces ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 7 of 44 Figure 1c Connectio...

Page 8: ...s ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 8 of 44 Figure 1d Connection...

Page 9: ...ces ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 9 of 44 Figure 1e Connectio...

Page 10: ...s ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 10 of 44 Figure 1f Connection...

Page 11: ...es ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 11 of 44 Figure 1g Connectio...

Page 12: ...writing Two directional information between EtherCAT and IO Link Mountable on 35mm Rail DIN Wide power supply input range 18 30V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need C...

Page 13: ...Page 13 of 44 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VDC Vmin Vmax HD67879 A1 xx 18V 30V Consumption at 24V DC Device W VA...

Page 14: ...e device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second wi...

Page 15: ...erCAT communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 IO Link comm green It blinks when IO Link communication is running Blinks quickly Boot state Blin...

Page 16: ...al point to point connection which uses standard unshielded cables IO Link sends all the sensor and actuator signals to the controller and in turn carries controller data to the sensor actuator level...

Page 17: ...ss B devices uses 5 pins on connectors and they require an additional aux power supply used for the actuation These devices are normally actuators AUX POWER SUPPLY for IO Link Class B The Aux Power Su...

Page 18: ...mation technology With EtherCAT the standard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read...

Page 19: ...ET The Ethernet connection must be made using Connector10 of HD67879 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 no...

Page 20: ...r use the available software that runs with Windows called SW67879 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last v...

Page 21: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable IO Link Master EtherCAT Slave Converter in order to co...

Page 22: ...there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section...

Page 23: ...0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 23 of 44 In the section Software Settings it is possible to enable disable some keyboard s command...

Page 24: ...n to the converter is defined If the field Obtain an IP Address Automatically DHCP for Cable Connection is checked DHCP for LAN connection is enabled If the field Enable DNS is checked DNS protocol is...

Page 25: ...onverter is defined In the field Subnet Mask the SubNet Mask of the converter is defined In the field GATEWAY the default gateway of the net is defined This feature can be enabled or disabled pressing...

Page 26: ...therCAT Slave Document code MN67879_ENG Revision 1 000 Page 26 of 44 Figure 4 IO Link Set Access window IO LINK SET ACCESS By Pressing the IO Link Set Access button from the main window for SW67879 Fi...

Page 27: ...Channels the index of the IO Link channel is defined In the field Pin 4 Mode the mode of the pin 4 of the IO Link device is defined if Io Link is selected a file IODD is needed If the field Read Pin...

Page 28: ...nk Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 28 of 44 Figure 6 IO Link IODD Catalog section By clicking on Insert IODD the window IO Link IODD Catalog appears Fig 6 This sect...

Page 29: ...field SubIndex the subindex of the IO Link process data is defined In the field Name the name of the IO Link process data is defined In the field Type the data format of the IO Link process data is d...

Page 30: ...parameter is defined In the field SubIndex the Subindex of the IO Link parameter is defined In the field Id the Id of the IO Link parameter is defined In the field Name the name of the IO Link parame...

Page 31: ...e Document code MN67879_ENG Revision 1 000 Page 31 of 44 In the field BitOff the bit offset of the IO Link parameter is defined In the field Default the default value of the IO Link parameter is defin...

Page 32: ...s are In the field Name the name of the IO Link pin is defined In the field Access the access of the IO Link pin is defined In the field Position the starting byte of the internal memory arrays where...

Page 33: ...e fields are In the field Code the code of the IO Link event is defined In the field Name the name of the IO Link event is defined In the field Type the type of the IO Link event is defined In the fie...

Page 34: ...EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 34 of 44 Figure 12 Device Identity section section Figure 11 Transport Layers section section In Device Identity section Fig 11 and Transpo...

Page 35: ...EtherCAT variables writeable by the EtherCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the d...

Page 36: ...nable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the fie...

Page 37: ...438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 37 of 44 ETHERCAT ESI FILE By pressing the EtherCAT ESI File button it is possible to save the ESI...

Page 38: ...urn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are...

Page 39: ...e LAN settings f you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privi...

Page 40: ...l IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 40 of 44 MECHANICAL DIMENSIONS Figure 16 Mec...

Page 41: ...79 IO Link Master EtherCAT Slave Converter Order Code HD67879 A1 2A IO Link Master EtherCAT Slave Converter IO Link ports 2 x Class A Order Code HD67879 A1 4A IO Link Master EtherCAT Slave Converter I...

Page 42: ...fweb com Phone 39 0438 30 91 31 User Manual IO Link Master EtherCAT Slave Document code MN67879_ENG Revision 1 000 Page 42 of 44 ACCESSORIES Order Code AC34011 Rail DIN Power Supply 220 240V AC 50 60H...

Page 43: ...ean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an appli...

Page 44: ...sh to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information ab...