SET COMMUNICATION:
This section defines the fundamental communication parameters of SNMP.
By Pressing the “
Set Communication
” button from the main window for SW67878 (Fig. 2)
the window “Set Communication” appears (Fig. 3).
The means of the fields for “IO-LINK” are:
In the fields “
Select Device
” the type of IO-LINK channels is defined;
The means of the fields for “SNMP Agent” are:
In the field “
IP ADDRESS
” the IP address of SNMP side of the converter is defined;
In the field “
SUBNET
Mask
” the SubNet Mask of SNMP side of the converter is
defined;
In the field “
GATEWAY
” the default gateway of the network is defined. This feature
can be enabled or disabled pressing the Check Box field. This feature is used for going
out of the net;
In the field "
SNMP Name of Station
" the name for SNMP Agent station is defined;
In the field "
Contact
" the contact for SNMP Agent station is defined;
In the field "
Location
" the location for SNMP Agent station is defined;
In the field “
Version
” the version of SNMP is defined;
If SNMP V3 is used, the following fields must be filled:
o
In the field “
User
” the user for the SNMP authentication is defined;
o
In the field “
Security Level
” the type of security used is defined;
o
In the field “
Authority
” the password for the SNMP authentication is defined;
o
In the field “
Authority Mode
” the mode used for the authentication is defined;
o
In the field “
Privacy
” the password for Privacy authentication is defined;
o
In the field “
Privacy Mode
” the mode used for Privacy is defined;
Figure 3: “Set Communication” window