Industrial
Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO:
www.adfweb.com
Phone +39.0438.30.91.31
User Manual
IO-Link / NMEA2000
Document code: MN67875_ENG Revision 1.000 Page 25 of 38
Figure 7: “
Process Data
” section
The “Process Data” section is used to define the IO-Link process data to link to NMEA2000 side (Fig. 7).
The meanings of the fields are:
In the field “
Id
” the Id of the IO-Link process data is defined;
In the field “
SubIndex
” the subindex of the IO-Link process data is defined;
In the field “
Name
” the name of the IO-Link process data is defined;
In the field “
Type
” the data format of the IO-Link process data is defined;
In the field “
Length
” the bit length of the IO-Link process data is defined;
In the field “
Gradient
” the multiplication factor of the IO-Link process data is defined;
In the field “
Offset
” the offset of the IO-Link process data is defined;
In the field “
Position
” the starting byte of the internal memory arrays where mapping/getting the value is defined;
In the field “
Start Bit
” the starting bit of the byte of the field “Position” is defined.