POWER SUPPLY: 
 

The devices can be powered between a wide range of tensions. For more details see the two tables below. 
 

 

VDC 

 

 

Vmin 

Vmax 

HD67872-A1-xx 

18V 

30V 

 
 

 

 

 

Consumption at 24V DC: 

Device 

W/VA 

HD67872-A1-xx 

 

Warning: 
    It is necessary to add to this consumption the one required by the IO-Link devices connected to the IO-Link channels. 

 
  
 
 
 
 
 
 
 
 
 
 
 
 

Caution:  Not reverse the polarity power

 

HD67872-A1-xx 

Summary of Contents for HD67872-A1-2A

Page 1: ...Master www adfweb com Product HD67861 Modbus Slave www adfweb com Product HD67862 Modbus TCP Master www adfweb com Product HD67863 Modbus TCP Slave www adfweb com Product HD67864 BACnet Master www ad...

Page 2: ...NDARDS 37 WARRANTIES AND TECHNICAL SUPPORT 38 RETURN POLICY 38 Pagina 2 di 38 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the foll...

Page 3: ...c QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly...

Page 4: ...rial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link J1939 Document code MN67872_ENG Revision 1 000 Page 4 of 38 EXAMPLE OF CONN...

Page 5: ...es ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link J1939 Document code MN67872_ENG Revision 1 000 Page 5 of 38 CONNECTION SCHEME Figure 1a Connecti...

Page 6: ...nic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link J1939 Document code MN67872_ENG Revision 1 000 Page 6 of 38 Figure 1b Connection scheme...

Page 7: ...nic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link J1939 Document code MN67872_ENG Revision 1 000 Page 7 of 38 Figure 1c Connection scheme...

Page 8: ...c Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link J1939 Document code MN67872_ENG Revision 1 000 Page 8 of 38 Figure 1d Connection scheme f...

Page 9: ...500 bytes in reading and 1500 bytes in writing Two directional information between J1939 and IO Link Mountable on 35mm Rail DIN Wide power supply input range 18 30V DC Wide temperature range 40 C 85 C...

Page 10: ...of 38 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VDC Vmin Vmax HD67872 A1 xx 18V 30V Consumption at 24V DC Device W VA HD67872...

Page 11: ...has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second with Dip1...

Page 12: ...ks very slowly 0 5Hz update in progress 2 J1939 comm green Flashing J1939 communication OFF No J1939 communication Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 IO Link comm...

Page 13: ...to point connection which uses standard unshielded cables IO Link sends all the sensor and actuator signals to the controller and in turn carries controller data to the sensor actuator level with rev...

Page 14: ...ices uses 5 pins on connectors and they require an additional aux power supply used for the actuation These devices are normally actuators AUX POWER SUPPLY for IO Link Class B The Aux Power Supply por...

Page 15: ...Ethernet connection must be made using Connector5 of HD67872 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms rela...

Page 16: ...vision 1 000 Page 16 of 38 CAN For terminate the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch B is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC p...

Page 17: ...the available software that runs with Windows called SW67872 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version...

Page 18: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable IO Link J1939 Converter in order to configure another...

Page 19: ...the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connecti...

Page 20: ...hone 39 0438 30 91 31 User Manual IO Link J1939 Document code MN67872_ENG Revision 1 000 Page 20 of 38 In the section Software Settings it is possible to enable disable some keyboard s commands for an...

Page 21: ...the data rate of J1939 is defined In the field TimeOut Data a time is defined When a J1939 message is not received in this time the data on IO Link side are set to 0xFF If the field Enable Peer to Pe...

Page 22: ...k J1939 Document code MN67872_ENG Revision 1 000 Page 22 of 38 Figure 4 IO Link Set Access window IO LINK SET ACCESS By Pressing the IO Link Set Access button from the main window for SW67872 Fig 2 th...

Page 23: ...nnels of the converter Fig 5 The meanings of the fields are In the field Channels the index of the IO Link channel is defined In the field Pin 4 Mode the mode of the pin 4 of the IO Link device is def...

Page 24: ...al IO Link J1939 Document code MN67872_ENG Revision 1 000 Page 24 of 38 Figure 6 IO Link IODD Catalog section By clicking on Insert IODD the window IO Link IODD Catalog appears Fig 6 This section is u...

Page 25: ...bIndex the subindex of the IO Link process data is defined In the field Name the name of the IO Link process data is defined In the field Type the data format of the IO Link process data is defined In...

Page 26: ...the field Index the Index of the IO Link parameter is defined In the field SubIndex the Subindex of the IO Link parameter is defined In the field Id the Id of the IO Link parameter is defined In the f...

Page 27: ...n the field TotBitLen the bit length of the array to which the IO Link parameter refers is defined In the field BitOff the bit offset of the IO Link parameter is defined In the field Default the defau...

Page 28: ...he field Name the name of the IO Link pin is defined In the field Access the access of the IO Link pin is defined In the field Position the starting byte of the internal memory arrays where mapping ge...

Page 29: ...are In the field Code the code of the IO Link event is defined In the field Name the name of the IO Link event is defined In the field Type the type of the IO Link event is defined In the field TimeOu...

Page 30: ...J1939 Document code MN67872_ENG Revision 1 000 Page 30 of 38 Figure 12 Device Identity section section Figure 11 Transport Layers section section In Device Identity section Fig 11 and Transport Ident...

Page 31: ...the data of J1939 message is defined it is an identifier In the field Source Address the address of the device that sends the frame is defined If the field Transport Protocol is checked the frame use...

Page 32: ...a number among 0 1 2 3 4 5 6 7 The number 0 is the highest priority and 7 is the lowest In the field Data Page the Data Page is defined the value can be 0 or 1 usually it is 0 In the field PGN the PGN...

Page 33: ...he device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn...

Page 34: ...tings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In...

Page 35: ...b com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual IO Link J1939 Document code MN67872_ENG Revision 1 000 Page 35 of 38 MECHANICAL DIMENSIONS Figure 17 Mechanical...

Page 36: ...tors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67872 IO Link J1939 Converter Order Code HD67872 A1 2A IO Link J1939 Converter IO Link ports 2 x Cla...

Page 37: ...tries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable co...

Page 38: ...change or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the...

Reviews: