ADF Web HD67803-KNX-B2 User Manual Download Page 2

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

CAN / KNX

 

 

Document code: MN67803_ENG     Revision 1.002   Pagina 2 di 28

 

 

 

INDEX:

 

 

 

Page 

INDEX 

UPDATED DOCUMENTATION 

REVISION LIST 

WARNING 

TRADEMARKS 

SECURITY ALERT 

EXAMPLE OF CONNECTION 

CONNECTION SCHEME 

CHARACTERISTICS 

CONFIGURATION 

POWER SUPPLY 

FUNCTION MODES 

LEDS 

CAN 

10 

KNX 

11 

ETHERNET 

12 

USE OF COMPOSITOR SW67803 

13 

NEW PROJECT / OPEN PROJECT 

14 

SOFTWARE OPTIONS 

15 

SET COMMUNICATION 

16 

KNX ACCESS 

17 

RECEIVE FRAMES 

19 

SEND FRAMES 

21 

UPDATE DEVICE 

23 

MECHANICAL DIMENSIONS 

25 

ORDERING INFORMATIONS 

26 

ACCESSORIES 

26 

DISCLAIMER 

27 

OTHER REGULATIONS AND STANDARDS 

27 

WARRANTIES AND TECHNICAL SUPPORT 

28 

RETURN POLICY 

28 

UPDATED DOCUMENTATION: 

 

Dear  customer,  we  thank  you  for  your  attention  and  we  remind  you  that 
you need to check that the following document is: 

 

Updated 

 

Related to the product you own

 

 
To  obtain  the  most  recently  updated document,  note  the  “document  code” 
that appears at the top right-hand corner of each page of this document. 
 
With  this  “Document  Code”  go  to  web  page  www.adfweb.com/download/ 
and  search  for  the  corresponding  code  on  the  page.  Click  on  the  proper 
“Document Code” and download the updates. 
 

 

REVISION LIST: 

 

 

 

WARNING: 
 

ADFweb.com reserves the right to change information in this manual about 
our product without warning. 
ADFweb.com is not responsible for any error this manual may contain. 

 

 

 

TRADEMARKS: 

 

All  trademarks  mentioned  in  this  document  belong  to  their  respective 
owners. 

Revision 

Date 

Author 

Chapter 

Description 

1.000 

15/06/2015 

Ff 

All 

First Release 

1.001 

26/02/2016 

Nt 

All 

Revision 

1.002 

13/06/2016 

Ff 

All 

Revision 

 

 

 

 

 

Summary of Contents for HD67803-KNX-B2

Page 1: ...r www adfweb com Product HD67802 BACnet Slave www adfweb com Product HD67804 CANopen www adfweb com Product HD67807 EtherNet IP www adfweb com Product HD67808 DeviceNet Master www adfweb com Product H...

Page 2: ...T 28 RETURN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own...

Page 3: ...QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly co...

Page 4: ...strial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN KNX Document code MN67803_ENG Revision 1 002 Pagina 4 di 28 EXAMPLE OF CONNEC...

Page 5: ...ices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN KNX Document code MN67803_ENG Revision 1 002 Pagina 5 di 28 CONNECTION SCHEME Figure 1 Connection...

Page 6: ...rectional information between KNX bus and CAN bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Comp...

Page 7: ...NX Document code MN67803_ENG Revision 1 002 Pagina 7 di 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24...

Page 8: ...unctions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch...

Page 9: ...in progress 2 CAN communication yellow Blinks when CAN frame is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 KNX communication yellow Blinks when KNX frame is recei...

Page 10: ...on 1 002 Pagina 10 di 28 CAN For terminate the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch C is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC par...

Page 11: ...ng to control dampers to the security to the heating monitoring to the conditioning to the hydric control and alarms to energy management and so on Characteristics Description TP1 256 Medium Shielded...

Page 12: ...used for programming the device The Ethernet connection must be made using Connector2 of HD67803 KNX B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The ca...

Page 13: ...e available software that runs with Windows called SW67803 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version o...

Page 14: ...contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable CAN KNX Converter in order to configure another devic...

Page 15: ...he possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection...

Page 16: ...other for Ethernet The means of the fields for KNX are In the field Type the type of KNX is defined fixd to KNX TP In the field ID Device the ID of the KNX side of the converter is defined The means o...

Page 17: ...ated by In the field APCI the APCI of the KNX message is defined You can choose between the following o Read it is used to send a reading request to a KNX device o Write it is used to send a writing r...

Page 18: ...e information In the field Bit Mode insert the start bit of the first byte of the field Position where start to insert the data read In the field Length the dimension of the KNX message is defined In...

Page 19: ...the COB from 1 to 8 The field TimeOut is used for put at zero the data into KNX if the CAN frame don t arrives with a frequency less than the time expressed in the field If the value in the field is 0...

Page 20: ...CAN KNX Document code MN67803_ENG Revision 1 002 Pagina 20 di 28 In the field Byte7 insert the address of the KNX array where saving 7th byte of the CAN message In the field Byte8 insert the address o...

Page 21: ...t the number of byte of the COB from 1 to 8 If the field OnChange is checked the frame is sent when the data from KNX change If the field OnTimer is checked the frame is sent cyclically with the delay...

Page 22: ...CAN KNX Document code MN67803_ENG Revision 1 002 Pagina 22 di 28 In the field Byte7 insert the address of the KNX array where taking 7th byte of the CAN message In the field Byte8 insert the address o...

Page 23: ...Device Found must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device P...

Page 24: ...Try with another PC Try to restart the PC Check the LAN settings Check the Wi Fi settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are usin...

Page 25: ...web com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN KNX Document code MN67803_ENG Revision 1 002 Pagina 25 di 28 MECHANICAL DIMENSIONS Figure 9 Mechanical dim...

Page 26: ...HD67803 KNX B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting Device Family HD67803 KNX CAN KNX Converter Order Code HD67803 KNX B2 CAN KNX Converter ACCESSORIE...

Page 27: ...ies with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable coll...

Page 28: ...ange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the pr...

Reviews: