background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

IEC 61850 Server / Serial

 

 

Document code: MN67755_ENG     Revision 1.000   Page 1 of 29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English

 

 

IEC 61850 Server / Serial - Converter

  

(Order Code:  HD67755-2-A1, HD67755-5-A1) 

 

For Website information:  

www.adfweb.com?Product=HD67755

   

 

For Price information: 

www.adfweb.com?Price=HD67755-2-A1

 

www.adfweb.com?Price=HD67755-5-A1

  

 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple Electrical isolation 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

For other IEC 61850 Server products see also the following link: 

 

Converter IEC 61850 Server to  

www.adfweb.com?Product=HD67733

      

(Modbus Master) 

www.adfweb.com?Product=HD67734

      

(Modbus Slave) 

www.adfweb.com?Product=HD67735

       

(Modbus TCP Master) 

www.adfweb.com?Product=HD67736

      

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67737

      

(BACnet Master) 

www.adfweb.com?Product=HD67738

      

(BACnet Slave) 

www.adfweb.com?Product=HD67739

      

(CAN) 

www.adfweb.com?Product=HD67740

      

(CANopen) 

www.adfweb.com?Product=HD67741

      

(DeviceNet Master) 

www.adfweb.com?Product=HD67742

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67743

      

(EtherNet/IP Master) 

www.adfweb.com?Product=HD67744

      

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67745

      

(J1939) 

www.adfweb.com?Product=HD67746

      

(KNX) 

www.adfweb.com?Product=HD67747

      

(MQTT) 

www.adfweb.com?Product=HD67748

      

(NMEA 0183) 

www.adfweb.com?Product=HD67749

      

(NMEA 2000) 

www.adfweb.com?Product=HD67750

      

(PROFIBUS Master) 

www.adfweb.com?Product=HD67751

      

(PROFIBUS Slave) 

www.adfweb.com?Product=HD67752

      

(PROFINET Slave) 

www.adfweb.com?Product=HD67753

      

(SNMP Manager) 

www.adfweb.com?Product=HD67754

      

(SNMP Agent) 

www.adfweb.com?Product=HD67756

      

(Ethernet) 

www.adfweb.com?Product=HD67B82

       

(PROFINET Master) 

www.adfweb.com?Product=HD67C65

      

(EnOcean) 

 

Do you have your customer protocol? Then go to: 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? Do you want help? 

www.adfweb.com?Cmd=helpme

 

User Manual   

 

Summary of Contents for HD67755-2-A1

Page 1: ...Master www adfweb com Product HD67738 BACnet Slave www adfweb com Product HD67739 CAN www adfweb com Product HD67740 CANopen www adfweb com Product HD67741 DeviceNet Master www adfweb com Product HD67...

Page 2: ...TIES AND TECHNICAL SUPPORT 29 RETURN POLICY 29 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Relat...

Page 3: ...evice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Page 4: ...Industrial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server Serial Document code MN67755_ENG Revision 1 000 Page 4 of 29 EXAMPLES OF CONNECTION...

Page 5: ...Industrial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server Serial Document code MN67755_ENG Revision 1 000 Page 5 of 29 CONNECTION SCHEME Figure 1a Connection scheme for HD67755 2 A1...

Page 6: ...Industrial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server Serial Document code MN67755_ENG Revision 1 000 Page 6 of 29 Figure 1b Connection scheme for HD67755 5 A1...

Page 7: ...pply Two directional information between IEC 61850 bus and Serial bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGU...

Page 8: ...5_ENG Revision 1 000 Page 8 of 29 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Page 9: ...the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used f...

Page 10: ...en Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 IEC 61850 communication green It blinks when a IEC 61850 request is received Blinks quickly Boot state Blin...

Page 11: ...t the RS232 cable not exceed 15 meters RS485 For terminate the RS485 line with a 120 resistor it is necessary to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet H...

Page 12: ...t be made using Connector3 and or Connector4 of the HD67755 X A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms rel...

Page 13: ...runs with Windows called SW67755 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on...

Page 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable IEC 61850 Server Serial Converter in order to configure another device in the same man...

Page 15: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible t...

Page 16: ...61850 Server Serial Document code MN67755_ENG Revision 1 000 Page 16 of 29 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside t...

Page 17: ...MMUNICATION By Pressing the Set Communication button from the main window for SW67755 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections in order to define th...

Page 18: ...61850 variables is defined TLS TRANSPORT LAYER SECURITY SERVER This section is used to define the main parameters of TLS protocol The means of the fields are If the field Enable TLS is checked the TL...

Page 19: ...Baudrate the baudrate for the serial line is defined In the field Parity the parity of the serial line is defined In the field Stop Bits the number of Stop Bits of the serial line is defined ETHERNET...

Page 20: ...ield Name the name of the IEC 61850 variable is defined In the field Type the data format of the IEC 61850 variable is defined If the field Read Only is checked the IEC 61850 variable is just in readi...

Page 21: ...ertificate button from the Main Window of SW67755 Fig 2 the Definition the list of Known Certificates window appears Fig 5 The data of the columns have the following meanings If the field Enable is ch...

Page 22: ...rnet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 o...

Page 23: ...program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program m...

Page 24: ...a from IEC 61850 side it is enough to send some simple commands on Serial port Reading data from HD67755 IEC 61850 Serial Request Byte Number Description 1 I 0x52 2 E 0x52 3 C 0x52 4 6 0x36 5 1 0x31 6...

Page 25: ...iting data to HD67755 Serial IEC 61850 Request Byte Number Description 1 I 0x52 2 E 0x52 3 C 0x52 4 6 0x36 5 1 0x31 6 8 0x38 7 5 0x35 8 0 0x30 9 W 0x57 10 0x2E 11 13 Index of IEC 61850 variable define...

Page 26: ...ial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server Serial Document code MN67755_ENG Revision 1 000 Page 26 of 29 MECHANICAL DIMENSIONS Figure 8 Mechanical dimensions scheme for HD677...

Page 27: ...able 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Modbus port 2 RS232 4 RS422 5 RS485 Device Family HD67755 IEC 61850 Server Serial Converter Order Code HD67755 2 A1 IEC 61850 Server...

Page 28: ...ion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recy...

Page 29: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Reviews: