background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

EtherNet/IP Master / Modbus TCP Slave 

 

Document code: MN67665_ENG     Revision 1.000    Page 2 of 25

 

INDEX: 

 

 

Page 

INDEX 

UPDATED DOCUMENTATION  

REVISION LIST 

WARNING 

TRADEMARKS 

SECURITY ALERT 

EXAMPLE OF CONNECTION 

CONNECTION SCHEME 

CHARACTERISTICS 

CONFIGURATION 

POWER SUPPLY 

FUNCTION MODES 

LEDS 

ETHERNET 

10 

USE OF COMPOSITOR SW67665 

11 

NEW PROJECT / OPEN PROJECT 

12 

SOFTWARE OPTIONS 

13 

SET COMMUNICATION  

15 

ETHERNET/IP ACCESS 

17 

UPDATE DEVICE 

18 

MECHANICAL DIMENSIONS 

20 

MODBUS MAP 

21 

ORDERING INFORMATIONS 

23 

ACCESSORIES 

23 

DISCLAIMER 

24 

OTHER REGULATIONS AND STANDARDS 

 

24 

WARRANTIES AND TECHNICAL SUPPORT 

25 

RETURN POLICY 

25 

Pagina 2 di 25

 

UPDATED DOCUMENTATION: 
 

Dear  customer,  we  thank  you  for  your  attention  and  we  remind  you  that 
you need to check that the following document is: 

 

Updated 

 

Related to the product you own

 

 
To  obtain  the  most  recently  updated document,  note  the  “document  code” 
that appears at the top right-hand corner of each page of this document. 
 
With  this  “Document  Code”  go  to  web  page  www.adfweb.com/download/ 
and  search  for  the  corresponding  code  on  the  page.  Click  on  the  proper 
“Document Code” and download the updates. 

 

 

REVISION LIST: 

 

Revision 

Date 

Author  Chapter 

Description 

1.000 

13/03/2018 

Ff 

All 

First release version 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: 
 

ADFweb.com reserves the right to change information in this manual about 
our product without warning. 
ADFweb.com is not responsible for any error this manual may contain.

 

 

 

TRADEMARKS: 
 

All  trademarks  mentioned  in  this  document  belong  to  their  respective 
owners. 

Summary of Contents for HD67665-A1

Page 1: ...aster devices see also the following links EtherNet IP Master from to www adfweb com Product HD67158 SNMP Agent www adfweb com Product HD67643 PROFIBUS Slave www adfweb com Product HD67645 CAN www adf...

Page 2: ...S AND TECHNICAL SUPPORT 25 RETURN POLICY 25 Pagina 2 di 25 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is U...

Page 3: ...terlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installatio...

Page 4: ...onic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual EtherNet IP Master Modbus TCP Slave Document code MN67665_ENG Revision 1 000 Page 4 of 25 EXAM...

Page 5: ...com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual EtherNet IP Master Modbus TCP Slave Document code MN67665_ENG Revision 1 000 Page 5 of 25 CONNECTION SCHEME Figur...

Page 6: ...erter It allows the following characteristics Two directional information between EtherNet IP and Modbus TCP Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide tempera...

Page 7: ...er Modbus TCP Slave Document code MN67665_ENG Revision 1 000 Page 7 of 25 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmi...

Page 8: ...the position of the Dip2 of Dip Switch A The first with Dip2 in Off position factory setting is used for the normal working of the device The second with Dip2 in On position is used for upload the Pro...

Page 9: ...ed ON Device powered OFF Device not powered 2 Modbus TCP communication green Blinks when a Modbus TCP request is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 Device...

Page 10: ...The Ethernet connection must be made using Connector3 or Connector4 of HD67665 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to t...

Page 11: ...verter use the available software that runs with Windows called SW67665 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the l...

Page 12: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherNet IP Master Modbus TCP Slave Converter in order...

Page 13: ...on there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the secti...

Page 14: ...8 30 91 31 User Manual EtherNet IP Master Modbus TCP Slave Document code MN67665_ENG Revision 1 000 Page 14 of 25 In the section Software Settings it is possible to enable disable some keyboard s comm...

Page 15: ...is defined In the fields SUBNET Mask the SubNet Mask for Modbus TCP side of the converter is defined In the fields GATEWAY the default gateway of the net is defined This feature can be enabled or disa...

Page 16: ...n the fields IP ADDRESS the IP address for EtherNet IP side of the converter is defined In the fields SUBNET Mask the SubNet Mask for EtherNet IP side of the converter is defined In the fields GATEWAY...

Page 17: ...e of the EtherNet IP slave to map on Modbus TCP side is defined In the field Num Input the number of consecutive Input byte to map on Modbus TCP side is defined In the field Start Output the starting...

Page 18: ...on Turn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations...

Page 19: ...the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator pr...

Page 20: ...IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual EtherNet IP Master Modbus TCP Slave Document code MN67665_ENG Revision 1 000 Page 20 of 25 MECHANICAL DIMENSIONS Figure 7...

Page 21: ...cription Holding Register 0 03 Input Bytes 0 1 of EtherNet IP side Holding Register 1 03 Input Bytes 2 3 of EtherNet IP side Holding Register 2 03 Input Bytes 4 5 of EtherNet IP side Holding Register...

Page 22: ...put Bytes 2 3 of EtherNet IP side Input Register 2 04 Input Bytes 4 5 of EtherNet IP side Input Register 719 04 Input Bytes N N 1 of EtherNet IP side Data in writing Type Address Function Description...

Page 23: ...part number is formed by a valid combination of the following HD67665 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67665 Ethernet IP Ma...

Page 24: ...ropean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an ap...

Page 25: ...wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information...

Reviews: