Industrial
Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO:
www.adfweb.com
Phone +39.0438.30.91.31
User Manual
NMEA 0183 / Modbus Slave - Converter
Document code: MN67616_ENG Revision 1.000 Page 4 of 30
EXAMPLE OF CONNECTION:
Page 1: ...ww adfweb com product HD67514 Modbus TCP Master www adfweb com product HD67515 Modbus TCP Server Do you have an your customer protocol See the following links www adfweb com Product HD67003 Do you nee...
Page 2: ...S 29 WARRANTIES AND TECHNICAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Up...
Page 3: ...mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with th...
Page 4: ...ronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus Slave Converter Document code MN67616_ENG Revision 1 000 Page 4 of 30 EXAMPL...
Page 5: ...b com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus Slave Converter Document code MN67616_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure...
Page 6: ...s ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus Slave Converter Document code MN67616_ENG Revision 1 000 Page 6 of 30 Figure 1b Connecti...
Page 7: ...racteristics electrical isolation between NMEA 0183 Modbus Power Supply Modbus Power Supply NMEA 0183 Multiple independent NMEA 0183 lines Mountable on Rail DIN Wide power supply input range 8 24V AC...
Page 8: ...code MN67616_ENG Revision 1 000 Page 8 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC The consumption depends to the code of the device For more details see the two tables bel...
Page 9: ...f the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for uploading th...
Page 10: ...ow LED Normal Mode Boot Mode 1 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet Link green ON Ethernet cable connected OFF Ethernet...
Page 11: ...0 resistor it is necessary to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor...
Page 12: ...1 31 User Manual NMEA 0183 Modbus Slave Converter Document code MN67616_ENG Revision 1 000 Page 12 of 30 RS422 For terminate the RS422 line with a 120 resistor it is necessary to put ON dip 1 for T li...
Page 13: ...31 User Manual NMEA 0183 Modbus Slave Converter Document code MN67616_ENG Revision 1 000 Page 13 of 30 RS232 The connection from RS232 socket to a serial port must be made with a Null Modem cable a s...
Page 14: ...HERNET The Ethernet connection must be made using Connector5 of HD67616 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 no...
Page 15: ...OR SW67616 To configure the Converter use the available software that runs with Windows called SW67616 It is downloadable on the site www adfweb com and its operation is described in this document Thi...
Page 16: ...ich contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable NMEA 0183 Modbus Slave Converter in order to conf...
Page 17: ...n there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the sectio...
Page 18: ...438 30 91 31 User Manual NMEA 0183 Modbus Slave Converter Document code MN67616_ENG Revision 1 000 Page 18 of 30 In the section Software Settings it is possible to enable disable some keyboard s comma...
Page 19: ...de MN67616_ENG Revision 1 000 Page 19 of 30 SET COMMUNICATION By Pressing the Set Communication button from the main window for SW67616 Fig 2 the window Set Communication appears Fig 3 The window is d...
Page 20: ...rial line is defined In the field ID Device the ID of Modbus side of the converter is defined If the field Read with Input Register Status Function is checked it is possible to read the Input bytes of...
Page 21: ...he serial port is enabled In the field Baudrate the baudrate for the serial line is defined In the field Parity the parity of the serial line is defined In the field Stop Bits the number of stop bits...
Page 22: ...checked the NMEA 0183 sentence is enabled In the field Serial Channel the serial port from which the sentence will be received is defined In the field Sentence the NMEA 0183 sentence is defined In the...
Page 23: ...ice Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF t...
Page 24: ...ance Try to repeat the operations for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operati...
Page 25: ...is created automatically In relation to the configuration defined it is possible to have two different maps Data in reading Type Address Function Description Input Register 0 03 Position 0 1 of intern...
Page 26: ...l IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus Slave Converter Document code MN67616_ENG Revision 1 000 Page 26 of 30 Figure 7a Mechanical dimensions...
Page 27: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus Slave Converter Document code MN67616_ENG Revision 1 000 Page 27 of 30 Figure 7b Mechanical di...
Page 28: ...1M 35mm DIN Rail mounting Serial Ports None 1 x RS232 2 x RS485 RS422 1 x RS232 1 x RS485 1 x RS422 Device Family HD67616 NMEA 0183 Modbus Slave Converter Order Code HD67616 A1 NMEA 0183 Modbus Slave...
Page 29: ...opean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an app...
Page 30: ...ish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information a...