ADF Web HD67561 User Manual Download Page 3

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

PROFIBUS Slave / Modbus Master 

 

Document code: MN67561_ENG     Revision 1.100    Page 2 of 22

 

 

INDEX: 

 
 

 

Page 

INDEX 

UPDATED DOCUMENTATION  

REVISION LIST 

WARNING 

TRADEMARKS 

SECURITY ALERT 

CONNECTION SCHEME 

CHARACTERISTICS 

CONFIGURTION 

POWER SUPPLY 

FUNCTION MODES 

LEDS 

PROFIBUS 

RS485 

RS232 

10 

USE OF COMPOSITOR SW67561 

11 

NEW PROJECT / OPEN PROJECT 

11 

SET COMMUNICATION  

12 

SET ACCESS 

14 

ERROR/DIAGNOSIS 

16 

GSD FILE 

16 

ASYNC MODBUS REQUEST 

17 

UPDATE DEVICE 

19 

MECHANICAL DIMENSIONS 

20 

ORDER CODE 

20 

ACCESSORIES 

20 

DISCLAIMER 

21 

OTHER REGULATIONS AND STANDARDS 

21 

WARRANTIES AND TECHNICAL SUPPORT 

22 

RETURN POLICY 

22 

PRODUCTS AND RELATED DOCUMENTS 

22 

UPDATED DOCUMENTATION: 

 

Dear  customer,  we thank  you  for  your  attention  and we  remind  you that 
you need to check that the following document is: 

 

Updated 

 

Related to the product you own

 

 
To obtain the most recently updated document, note the “document code” 
that appears at the top right-hand corner of each page of this document. 
 
With  this  “Document  Code”  go  to  web  page  www.adfweb.com/download/ 
and  search  for  the  corresponding  code  on  the  page.  Click  on  the  proper 
“Document Code” and download the updates. 
 
To obtain the updated documentation for the product that you own, note 
the  “Document  Code”  (Abbreviated  written  "Doc.  Code"  on  the  label  on 
the  product)  and  download  the  updated  from  our  web  site 
www.adfweb.com/download/  

 

 

REVISION LIST: 

 

Revision 

Date 

Author  Chapter 

Description 

1.003 

15/07/2010 

FT 

All 

Revision 

1.004 

03/11/2010 

Dp 

All 

Add new features 

1.005 

15/01/2013 

Fl 

All 

Added new chapters 

1.100 

26/09/2013 

Dp 

All 

Added new Chapters 

 

WARNING: 

 

ADFweb.com  reserves  the  right  to  change  information  in  this  manual 
about our product without warning. 
ADFweb.com is not responsible for any error this manual may contain. 

 

 
 

TRADEMARKS: 

 

All trademarks mentioned in this document belong to their respective 
owners.

Summary of Contents for HD67561

Page 1: ......

Page 2: ...CANopen to Modbus See also the following links www adfweb com Product HD67001 Modbus RTU Master www adfweb com Product HD67502 Modbus RTU Slave www adfweb com Product HD67004 Modbus TCP Master www adf...

Page 3: ...o check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page...

Page 4: ...chanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the...

Page 5: ...DFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFIBUS Slave Modbus Master Document code MN67561_ENG Revision 1 100 Page 4 of 22 CONNECTION SCHEME Figure...

Page 6: ...Gateway allows the following characteristics Baud Rate and Parity changeable with software Mountable on 35mm Rail DIN Power Supply 8 19V AC or 8 35V DC Temperature range 40 C to 85 C Serials Protocol...

Page 7: ...Slave Modbus Master Document code MN67561_ENG Revision 1 100 Page 6 of 22 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vm...

Page 8: ...device has got two functions mode depending of the position of the Dip2 of Dip Switch A The first with Dip2 in Off position factory setting is used for the normal working of the device The second wit...

Page 9: ...22 LEDS The device has got three LEDs that are used to give information of the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode 1 Not use...

Page 10: ...79A Continuous Armor DataBus ISA SP 50 PROFIBUS Cable RS485 For terminate the RS485 line with a 220 resistor it is necessary to put ON dip 2 like in figure The maximum length of the cable should be 12...

Page 11: ...MN67561_ENG Revision 1 100 Page 10 of 22 RS232 The connection from RS232 socket to a serial port example one from a personal computer must be made with a Null Modem cable a serial cable where the pins...

Page 12: ...oftware works with MSWindows MS 2000 XP Vista Seven 8 When launching the SW67561 the right window appears Fig 2 NEW PROJECT OPEN PROJECT The New Project button creates the folder which contains the en...

Page 13: ...ield RS485 is checked the serial line in use is the RS485 In the field Baud Rate the baudrate for the serial line is defined In the field Parity the parity of the serial line is defined In the field S...

Page 14: ...niostic If the field Enable PROFIBUS Diagosis is checked the gateway use the Diagnosis to show an error of one or more Modbus device The Enable check Modbus Error must be selected for enable this opti...

Page 15: ...used to write the data that will be sent to the Slave ProfiBus ProfiBus IN Serial Read The means of the fields are In the field Slave ID the address of the Modbus device you have to read is defined In...

Page 16: ...D the address of the Modbus device that you must write is defined In the field Address Register the start address of the register to be written is defined In the field NPoint insert the number of cons...

Page 17: ...yte If there a problem in Modbus side after the first 6 byte there is a byte with a fix part 0x40 plus the number of follow bytes plus 1 For example if you want to monitor 10 Modbus devices you fond t...

Page 18: ...TX It is the Control byte used to send the request 2 Spare Not used Reserved 3 ID_Device The ID of the Modbus Slave where to send the request 4 Function_Code The Function Code of the request 5 6 Addre...

Page 19: ...Converter waiting an answer from the Modbus Salve 5 The Control_RX byte pass to the value 3 the request command is finish In the Status_Request is possible to read the result of the request and in the...

Page 20: ...Insert the Boot Jumper For more info see the Connection scheme Turn ON the device Check the BOOT Led It must blink quickly For more info see the Connection scheme Select the COM port and press the Co...

Page 21: ...of 22 MECHANICAL DIMENSIONS ORDER CODE Order Code HD67561 PROFIBUS Slave Modbus Master Converter ACCESSORIES Order Code AC34107 Null Modem Cable Fem Fem DSub 9 Pin 1 5 m Order Code AC34114 Null Modem...

Page 22: ...European countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an...

Page 23: ...equest you need to provide detailed information about the problem 2 Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be acce...

Reviews: