ADF Web HD67450 User Manual Download Page 2

   

Industrial

 

Electronic Devices 

 

 

 
ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

SNMP Manager / CANopen

 

 

Document code: MN67450_ENG     Revision 1.000    Page 2 of 33 

 

INDEX: 

 

 

Page 

INDEX 

UPDATED DOCUMENTATION 

REVISION LIST 

WARNING 

TRADEMARKS 

SECURITY ALERT 

EXAMPLE OF CONNECTION 

CONNECTION SCHEME 

CHARACTERISTICS 

CONFIGURATION 

POWER SUPPLY 

LEDS 

CAN 

10 

ETHERNET 

11 

USB 

11 

USE OF COMPOSITOR SW67450 

12 

NEW PROJECT / OPEN PROJECT 

13 

SOFTWARE OPTIONS 

14 

SET COMMUNICATION 

15 

SNMP MANAGER 

16 

SET SDO SERVER 

18 

SET SDO CLIENT 

19 

SET PDO ACCESS 

21 

EDS FILE 

23 

UPDATE DEVICE 

24 

MECHANICAL DIMENSIONS 

26 

ORDERING INFORMATIONS 

30 

ACCESSORIES 

31 

DISCLAIMER 

32 

OTHER REGULATIONS AND STANDARDS 

32 

WARRANTIES AND TECHNICAL SUPPORT 

33 

RETURN POLICY 

33 

 
 
 
 

UPDATED DOCUMENTATION: 

 

Dear  customer,  we  thank  you  for  your  attention  and  we  remind  you  that 
you need to check that the following document is: 

 

Updated 

 

Related to the product you own

 

 
To  obtain  the  most  recently  updated document,  note  the  “document  code” 
that appears at the top right-hand corner of each page of this document. 
 
With  this  “Document  Code”  go  to  web  page  www.adfweb.com/download/ 
and  search  for  the  corresponding  code  on  the  page.  Click  on  the  proper 
“Document Code” and download the updates. 

 

 

REVISION LIST: 

 

Revision 

Date 

Author 

Chapter 

Description 

1.000 

15/06/2017 

Ff 

All 

First released version 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

WARNING: 
 

ADFweb.com reserves the right to change information in this manual about 
our product without warning. 
ADFweb.com is not responsible for any error this manual may contain.

 

 

 

TRADEMARKS: 
 

All  trademarks  mentioned  in  this  document  belong  to  their  respective 
owners. 

 

Summary of Contents for HD67450

Page 1: ...re range 40 C 105 C 40 F 221 F For other Gateways Bridges CAN from to Modbus See also the following links www adfweb com product HD67012 Modbus RTU Slave www adfweb com product HD67514 Modbus TCP Mast...

Page 2: ...TANDARDS 32 WARRANTIES AND TECHNICAL SUPPORT 33 RETURN POLICY 33 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following documen...

Page 3: ...s etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assem...

Page 4: ...Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual SNMP Manager CANopen Document code MN67450_ENG Revision 1 000 Page 4 of 33 EXAMPLE OF C...

Page 5: ...DFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual SNMP Manager CANopen Document code MN67450_ENG Revision 1 000 Page 5 of 33 CONNECTION SCHEME Figure 1a Conne...

Page 6: ...Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual SNMP Manager CANopen Document code MN67450_ENG Revision 1 000 Page 6 of 33 Figure 1b Connection sch...

Page 7: ...Seal 1 5 connectors If is resined the enclosure like the AMP SuperSeal 1 5 connectors is waterproof The device have these characteristics Triple 4kV isolation between Power Supply Ethernet CAN Varnish...

Page 8: ...ocument code MN67450_ENG Revision 1 000 Page 8 of 33 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax HD67...

Page 9: ...he table below LED Normal Mode Boot Mode 1 Device state green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 CAN communication green Blinks when CANopen fram...

Page 10: ...HD67450 E7x xx device must be made with a AMP SuperSeal 1 5 Male connector The pinout of Female connector of the board is at right side of the page The termination of CANopen line with a 120 resistor...

Page 11: ...rms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of...

Page 12: ...se the available software that runs with Windows called SW67450 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last vers...

Page 13: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable SNMP Manager CANopen Converter in order to configure a...

Page 14: ...e is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Conn...

Page 15: ...e 39 0438 30 91 31 User Manual SNMP Manager CANopen Document code MN67450_ENG Revision 1 000 Page 15 of 33 In the section Software Settings it is possible to enable disable some keyboard s commands fo...

Page 16: ...out of the net In the field SNMP Name of Station the name of the SNMP side of the converter is defined The means of the fields for CANopen are In the field ID Device the CANopen ID for the converter i...

Page 17: ...he field Type the type of data to read write String or Int is defined In the field Mode the type of SNMP request used Get Set or Trap is defined By checking the field On Change the SNMP request only f...

Page 18: ...he field Priv Pass the password for Privacy authentication is defined o In the field Security Level the type of security used is defined o In the field Auth Mode the mode used for the authentication i...

Page 19: ...o the SNMP side The data of the columns have the following meanings In the field Index the address of the SDO Object is defined In the field SubIndex the second address of the SDO Object is defined If...

Page 20: ...the SDO Read are In the field Device ID the ID of the device to read is defined In the field Index the address of the SDO to read is defined In the field SubIndex the second address of the SDO to read...

Page 21: ...ime to make the request is defined If the field On Change is checked the converter sends the writing request when the data from SNMP changes In the field Address Byte1 the address of the SNMP array wh...

Page 22: ...an be between 1 and 8 bytes In the field Add B1 the address of the SNMP array where coping the 1st byte of the RPDO is defined In the field Add B2 the address of the SNMP array where coping the 2nd by...

Page 23: ...e SNMP array where taking the 4th byte of the TPDO is defined In the field Add B5 the address of the SNMP array where taking the 5th byte of the TPDO is defined In the field Add B6 the address of the...

Page 24: ...ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK...

Page 25: ...pdating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vi...

Page 26: ...Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus TCP Slave Document code MN67425_ENG Revision 1 100 Page 26 of 33 MECHANICAL...

Page 27: ...ustrial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus TCP Slave Document code MN67425_ENG Revision 1 100 Page 27 of 33 Type...

Page 28: ...ustrial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus TCP Slave Document code MN67425_ENG Revision 1 100 Page 28 of 33 Type...

Page 29: ...ustrial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual CAN Modbus TCP Slave Document code MN67425_ENG Revision 1 100 Page 29 of 33 Type...

Page 30: ...ERING INFORMATIONS The ordering part number is formed by a valid combination of the following HD67450 E y z s f Fixing lugs A Type A B Type B C Type C D without fixing lugs CANopen Termination Y Termi...

Page 31: ...Rail DIN Power Supply 220 240V AC 50 60Hz 24 V DC Order Code AC67402 Cable Super Seal 1 5 MALE 2 pole 1 0 Meter Order Code AC67402 3 Cable Super Seal 1 5 MALE 2 pole 3 0 Meters Order Code AC67403 Cabl...

Page 32: ...countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicabl...

Page 33: ...exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about t...

Reviews: