background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

M-Bus / Ethernet - Converter

 

 

Document code: MN67030_ENG     Revision 2.100    Page 12 of 22 

 

 

NEW CONFIGURATION / OPEN CONFIGURATION:

 

 
The  “

New Configuration

” button creates the folder which contains the entire device’s configuration. 

 

 

 

 

 

 

 
 

A device’s configuration can also be imported or exported: 

 

To  clone  the  configurations  of  a  Programmable  “M-Bus  /  Ethernet  -  Converter”  in 

order to configure another device in the same manner, it is necessary to maintain the 
folder and all its contents; 

 

To clone a project in order to obtain a different version of the project, it is sufficient 

to  duplicate  the  project  folder  with  another  name  and  open  the  new  folder  with  the 
button “

Open Configuration

”. 

Summary of Contents for HD67030-B2-160

Page 1: ...ucts see also the following link Converter M Bus Master www adfweb com Product HD67021 RS232 www adfweb com Product HD67022 RS485 www adfweb com Product HD67024 USB M Bus Analyzer Scanner Sniffer www...

Page 2: ...ENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently update...

Page 3: ...cks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation ass...

Page 4: ...lectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter Document code MN67030_ENG Revision 2 100 Page 4 of 22 EXAMPLE OF...

Page 5: ...web com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter Document code MN67030_ENG Revision 2 100 Page 5 of 22 CONNECTION SCHEME Figure 1 Conn...

Page 6: ...Supply 15 21V AC or 18 35V DC Temperature range 40 C to 85 C At the Converter can be connected up to 250 standard M Bus devices This number depends of the code expressed by the xxx number HD67030 B2...

Page 7: ...AC and 18 35V DC The consumption depends to the code of the device For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 15V 21V 18V 35V Consumption at 24V DC Device No Load W VA Full...

Page 8: ...Dip Switch A of HD67030 B2 xxx The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for upload...

Page 9: ...of the LEDs are described in the table below LED Normal Mode Boot Mode 1 Device state green Blinks slowly 1Hz Blinks quickly 2 M Bus Comm yellow Blinks quickly when receive M Bus data Blinks quickly 3...

Page 10: ...he use of a cross cable M BUS The M Bus is a unpolarized bus A two wire standard telephone cable JYStY N 2 0 8 mm is used as the transmission medium for the M Bus The maximum distance between a slave...

Page 11: ...er use the available software that runs with Windows called SW67030 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last...

Page 12: ...ich contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable M Bus Ethernet Converter in order to configure an...

Page 13: ...ere is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Co...

Page 14: ...a 330000 Baudrate 50 ms o By selecting Manual Value is possible to insert in the value expressed in milliseconds manually The parameters of Ethernet are IP address where is specified the IP address as...

Page 15: ...is addressed to If the Client cannot open the connection to the HD67030 B2 when using TCP is possible to configure the HD67030 B2 to open the connection to the client For doing this is necessary to ch...

Page 16: ...or hardware with CS B244 Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When a...

Page 17: ...the update Try with another PC Try to restart the PC If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven or Vista or 8 make sur...

Page 18: ...05 for hardware with CS B244 Press the Ping button must appear Device Found Press the Next button Press the Execute update firmware button to start the download When all the operations are OK turn off...

Page 19: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual M Bus Ethernet Converter Document code MN67030_ENG Revision 2 100 Page 19 of 22 MECHANICAL DIMENSIONS Figure 7 Mechani...

Page 20: ...ting Device Family HD67030 M Bus Master Ethernet Converter Order Code HD67030 B2 20 Converter M Bus Master Ethernet up to 20 slaves connected to M Bus Order Code HD67030 B2 40 Converter M Bus Master E...

Page 21: ...n countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applica...

Page 22: ...to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about...