Turn on the central heating system
and re-set controls to the customer
requirements. Open any bypass valves
previously closed. Commission the
system following the manufacturer’s
instructions. Before leaving the
property, carry out the final job –
service
MagnaClean
filter ensuring a
final check is carried out for leaks.
Check that all radiators and bypasses
are turned OFF, leaving the furthest
radiator from the boiler open. Turn on
the filling loop and allow the mains
water to flush through the system. Allow
the water to drain out to a convenient
point outside until clear. When
complete, fill and vent the radiator and
allow to circulate. Always open up the
next radiator before turning off the
cleansed radiator. Repeat this process
on each radiator until system flushing is
complete.
13
Turn off the filling loop and HTV
connector isolation valve 1, drain and
remove
MagnaCleanse
assembly.
All the radiators should now be full.
Reinstall/Install the
MagnaClean
filter
to system.
N.B Refer to MagnaClean installation
instructions.
14
Add a suitable inhibitor, such as
MC1+
®
,
into the canister. i.e. use the pro-fill
bleed valve or remove canister lid
assembly and dose filter. Open up the
isolation valves and remove any air by
venting using filter air vent.
15
16
Remember to monitor the MagnaCleanse throughout operation.