background image

2

7

 

≤45

1.The incline angle of the cabinet could 

   not be over 45

°

 during transportation. 

   Don't make ice maker upside-down in 

   case the compressor or refrigerating 

   system troubles occur.

2.When  the i

 will be used for the first  time or 

ce 

 

flaker

  reused after let it lie idle for a long time,drainage screw

  should be unscrewed and a container should be placed under

  it to receive wasted water.The first and second ice making 

  cycles are just for tube system cleaning, the ice made 

  should not be taken.After the water drained and drainage 

  screw is screwed, the normal ice making procedures will 

  begin and you can take the ice. 

Features

Notes before operation

TROUBLE

CAUSE

REMEDY

Ice

  

f laker does not

work.

1. The voltage is lower
    than 187V
2. The ambient
    temperature is too low
    (lower than 10 )

1. Turn off the machine,restart
    when the voltage is normal.
2. Try again when the ambient
    temperature is over 10

℃.

Compressor works,
but no ice was made.

1. Refrigerant leaks.
2. Refrigerating system
    blocks.
3.Solenoid valve opens
   constantly.
4.Condensing fan does not 
   work.
5.Hall element has no 
   interaction.

Compressor does
not work.

1. Water shortage.
2. Ice full.
3. Compressor stops(the
    temperature of shell is
    too high).

1. Check the water supply 
    system (water valve and 
    water supply tube).
2. Take some ice out.
3. Turn off the machine and 
    restart 1 hour later.

The indicator of
water shortage lights.

1. Water shortage in water 
    supply system.
2. Water valve damaged.
3. Tap water pressure too low.

The indicator of 
trouble lights.

1. There is some ice has not
    dropped.
2. The water tank has not
     turned to proper position.

1. Check whether the solenoid
    valve could be open, if not,
    replace with a new one.
2. Check whether the switch(SQ1)
    could get information from the
    rotation of the eccentric wheel.
    Check whether the rotating
    motor and eccentric wheel skid
    around. Check whether the 
    motor gear is dammaged when
    rotate the eccentric wheel by 
    hand.

1. Refill the refrigerant and test
    leakage.
2. Replace filter for the N

2

 

    filling system.
3. Replace the solenoid valve.
4. Check whether the
    condensing for works.
5. Check whether the Hall element
    is fine and in proper position.

1. Check and make sure the
    water supply system is fine, 
    then restart.
2. Check the water valve.
3. If it is for tap water, the water
    pressure should not be lower
    than 1Kg/cm .

2

TROUBLE AND SHOOTING

( for reference of users and technicians )

Computerized control , easy operation & high reliability

Stainless steel exterior

Bell shaped clear ice

Self malfunction analysis

If water shortage or something wrong with the water 

supply system,the Ice Maker will restart automatically 

in 24hours otherwise you will stop the unit and restart

 it again.

PU foamed ice storage cabinet ,so it is insulated

well and it could prevent the ice from melting 

High Efficiency , low power consumption

Use fresh water to make clear and healthful ice 

Reviews: