Safety Notices and Precautions

 

 

When using this equipment, safety precautions should always be followed, including the following: 

 

 

Please make sure that the operator is an authorized and licensed technician before you allow 
him/her to install and operate the products. Be sure to strictly follow this instruction guide during 

installation and using. The manufacturer is not responsible for any danger or accidents caused by 

improper operation or maintenance. 

 

 

Do not store flammable or explosive objects around the product. Keep all flammable and 

explosive objects at a safe distance away from the product for normal using. 

 

 

Place the product in a reasonable position. Regarding related matters of gas, customers should 

execute the requirements of local gas supply sector. 

 

 

If you smell a gas leak, turn off the gas valves immediately and call the gas company. 

 

 

The product should not be operated by those under 18 years of age, or those with physical or 

mental disorders, or disabilities that lack the necessary knowledge or experience unless with 

appropriate instructions and sufficient safety. 

 

 

Warning! For your safety, do not place petrol and other flammables nearby. Please keep clean 

and free of flammables surroundings. 

 

 

Warning! Any erroneous installation, adjustment and refit may cause property. 

 

 

Do not use out of doors. 
 

 

Damage or personal injury and maintenance failure. Read the instructions carefully before 

installation and using. 

 

 

Warning! Operation instruction must be placed in a conspicuous location. When customers smell 

gas in the process of using, should take safety precautions immediately. Immediately turn off the 
main gas valve, extinguish all heat and flames. Safety information can be obtained from your 

local gas suppliers. 

 

 

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION. 

 

 

The LAVA ROCK GRILLs and outside surfaces may become hot after use, so you must be careful 
to touch. 

 

 

During operation, do not directly touch burners and cooking grates. 

  

 

Turn off the equipment as repairing, maintaining and cleaning. 

 

 

If the equipment has any problems of equipment damage, gas piping leaks, igniter or valves 

damage, or lose product accessories, do not operate, and call for the service immediately. 

 

 

The use of attachments not recommended or sold by the manufacturer may cause fire, personal 

injury or even death. 

 

 

The equipment is used for cook, not available for any other use. 

 

 

The equipment does not contain any user-serviceable parts. Dealers or technicians will repair it.  

 

 

Do not take apart any spare parts without authorization. 

 

 

Never change any other parts without authorization to this equipment, otherwise, may cause 

hazards, and the manufacturer has the right not to provide warranty service. 

 

 

Steel cutting producers used to manufacture with sharp edges. The manufacturer has dealt with 

these sharp edges during production; however, we insist the operator take care when in contact 
with this piece of equipment. 

 

Summary of Contents for ECB-16S

Page 1: ...ions for adapting the appliance to the conditions for use in that country WARNING For your safety do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliances Keep the area free and clear of combustible WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation opera...

Page 2: ......

Page 3: ...lues Dimensions 6 Installation 7 Installation Requirements Unpacking Location Clearances Assembly Gas Connection LP Gas cylinder and compartment Commissioning Operation 12 Operation Guide Lighting Main Burners Turning OFF Main Burners Main burner air supply CAUTION Cleaning and Maintenance 15 General After Each Use Daily Cleaning Periodic Maintenance Trouble Shooting 17 Explosion Drawing 19 Parts ...

Page 4: ...E POSTED IN A PROMINENT LOCATION THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER WARNING GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF FIRE THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS ...

Page 5: ...e Read the instructions carefully before installation and using Warning Operation instruction must be placed in a conspicuous location When customers smell gas in the process of using should take safety precautions immediately Immediately turn off the main gas valve extinguish all heat and flames Safety information can be obtained from your local gas suppliers DO NOT SPRAY AEROSOLS IN THE VICINITY...

Page 6: ...er s explicit authorization Manufacturers refused to undertake responsibility to third parties as the following reasons Not follow this instruction guidance and warning in using and testing Not in accordance with the requirements of technical parameters using this product Incorrectly or irrationally using the product by untrained personnel Not obey the local law using this product Be repaired or c...

Page 7: ...ed The Gas LAVA ROCK GRILL Four Feet Instruction Manual The gas lava rock Product specification list Gas orifice dia Gas pres Total power ECB 48S ECB 36S ECB 24S ECB 16S G30 1 3mm 29mbar 6kWx4 6kW x3 6kW x2 6kW G30 1 2mm 37mbar 6kW x4 6kW x3 6kW x2 6kW G30 1 1mm 50mbar 6kW x4 6kW x3 6kW x2 6kW G20 2 2mm 20mbar 7 5kW x4 7 5kW x3 7 5kW x2 7 5kW G25 3 2 2mm 25mbar 7 3kW x4 7 3kW x3 7 3kW x2 7 3kW Pre...

Page 8: ...5 Dimensions ...

Page 9: ...ction from the appliance including all protective plastic coating from the exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor Ensure that the 4 adjustable feet are fitted with the protruding centre screw Report any deficiencies to the distributor who supplied the appliance Check that the available gas supply is correct ...

Page 10: ... the Rating label The input rate should be checked against the available gas supply line capacity Particular note should be taken if the appliance is being added to an existing installation d The gas supply tubing or hose shall comply with the national requirements in force and shall be periodically examined and replaced as necessary e Only local national requirements rubber or PVC flexible hose N...

Page 11: ...regulator refer to the picture of Install the Regulator A suitable jointing compound which resists the breakdown action of propane must be used on every gas line connection unless compression fittings are used 4 Check all gas connections for leakages 5 Check that the gas operating pressure NOTE The operating pressure to be measured at the manifold test point and with 2 burners operating at the Hig...

Page 12: ...n well ventilation space Gas cylinder shall never be moved during operation period it shall be fixed with rigid support 2 If gas cylinder was inserted with compartment effective ventilation is provided by openings compartment base and upper side areas The total area of the openings in the upper part being at least 1 100th of the floor area of the compartment and that of the openings at the base be...

Page 13: ...ted in the areas of correct lighting operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and a record of the Date of Purchase Date of Installation and the Serial Number of the Appliance must be recorded and kept with this manual These details can be found on the Rating label refer to the Gas Connection section NOTE If for some reason it i...

Page 14: ...d operation practices can reduce the life of the appliance To use this appliance correctly please read the following sections carefully Lighting the Main Burner Turning off the Main Burner CAUTION This appliance is for professional use and is only to be used by qualified persons Only authorized service persons are to carry out installation servicing or gas conversion operation operations Component...

Page 15: ...trol knob to the OFF position The main burner will extinguish Main burner air supply 1 For efficient burner operation a proper balance of gas volume and primary air supply must be maintained which will result in complete combustion Insufficient air supply results in a yellow streaming flame Primary air supply is controlled by an air shutter on the front of the burner 2 Loosen the screws on the fro...

Page 16: ...ain burners to maintain the best function of the thermostat valve after turning off the main burners IMPORTANT Should any abnormal operation like ignition problems abnormal burner flame burner control problems partial or full loss of burner flame in normal operation be noticed the appliance requires IMMEDIATE service by a qualified service person and should not be used until such service is carrie...

Page 17: ...OCK GRILL usage is very high we recommend that the weekly cleaning procedure is carried out on a more frequent basis Ensure that protective gloves are worn during the cleaning process DO NOT use harsh abrasive detergents strong solvents or caustic detergents as they will damage the grate and burners Allow these items castings to cool and remove for cleaning Parts protected by the manufacturer or h...

Page 18: ... clean the interior and exterior surfaces of the Gas LAVA ROCK GRILL with hot water a mild detergent solution and a soft scrubbing brush Note that the gas control knobs are a push fit onto the gas control valve spindles and can be removed to allow cleaning of the front of the control panel b Baked on deposits or discoloration may require a good quality stainless steel cleaner or stainless steel wo...

Page 19: ...urned on and that bottles are not empty Call the service provider Nozzle occlusion Dredge nozzle Thermocouple connection loose Tighten thermocouple Thermocouple damage Replace thermocouple Gas control valve failure Replace control valve No spark flame on main burner Faulty battery for electronic pulse ignition device Put No 7 battery into ignition device Faulty electronic pulse ignition device Rep...

Page 20: ...contact your nearest authorized service branch When ordering replacement parts please quote the part number and the description listing below If the part required is not listed below request the part by description and quote model number and serial number which is shown on the rating plate CAUTION Please replace the corresponding warning label that shows the gas type operated when the qualified pe...

Page 21: ... 18 Explosion Drawing ECB 48S ...

Page 22: ... 11 pressure test plug 4 12 inlet gas pipe 1 13 Adjustable steel foot 4 14 thermocouple fixation plate 4 15 thermocouple 4 16 ignitor pin with wire 4 17 U shape burner 4 18 Radiant plate 8 19 Radiant plate small 4 20 plate to increase height of grill 1 21 orifice 4 22 nut to fix angle 4 23 orifice fixation plate 4 24 angle connector for orifice 4 25 nut 4 26 10 clamp 8 27 10x400 corrugated pipe 4 ...

Page 23: ... ECB 48S Imported By ADEXA DIRECT LIMITED GROUND FLOOR UNIT 1 214 PURLEY WAY CROYDON CR0 4XG LONDON UNITED KINGDOM Serial Number Year of Manufacture Brand ADEXA Application of Council Directive s EU 2016 426 9 March 2016 Standards EN 203 1 2014 EN 203 2 10 2007 EN 203 3 2009 I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s Date 01...