IMPORTANT SAFETY PRECAUTIONS

READ AND SAVE THESE

INSTRUCTIONS CAUTION:

For residential use only. Do not use to exhaust hazardous or explosive materials and/or vapors.

CAUTION:

Range hood may have very sharp edges; please wear protective gloves when installing, cleaning or

servicing the unit.
This appliance must be installed by a qualified technician. The manufacturer declines all

responsibility in case of failure to adhere to safety standards. Install this hood in accordance with

all the specified requirements

.

WARNING

To reduce the risk of fire, electric shock or injury to persons, observe the following:

manufacturer.

All other servicing should be referred to a qualified technician

.

CAUTION:

To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into

spaces within walls, ceilings, attics, crawl spaces, or garages.
Automatically operated device - to reduce risk of injury disconnect from power supply before servicing.

Before servicing or cleaning the unit, switch power off at the service panel and lock the

 service   

       disconnect ing means st op revent  pow er from being sw it ched on accident ally. If t he service           
       disconnect ing means cannot  be locked, securely fast en a not iceable w arning device, such a t ag,

       t o t he service panel.

Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the

Follow the heating

 equipment  manufact urer's guide line and safet y st andards such as t hose published

       by t he Nat ional Fire Prot ect ion Associat ion (NFPA) and t he local code aut horit ies.

equipment to preventback-drafting.

Do not make alterations to the original wiring.

Do not attempt to repair or replace any part of your hood unless it is specifically recommended in this

       manual.

Sufficient air is needed for proper combustion and exhausting of gases through the chimney of fuel burning

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Ducted fans must always be vented to the outdoors.

Installation work and electrical wiring must be done by a qualified person in accordance with all

       applicalbe codes &  st andards, including Fire-rat ed const ruct ion.

4

Summary of Contents for AP238- PS15- 36

Page 1: ...NT HOOD MODEL AP238 PS15 36 INSTALLATION GUIDE USE AND CARE MANUAL IMPORTANT Read and save these instructions Installer Leave this manual with the homeowner Homeowner Keep this guide for future refere...

Page 2: ......

Page 3: ...de them to the electrical inspector in your area INSTALLER Please leave these instructions with the owner of the unit OWNER Keep these instructions for future reference SECURITY WARNING Turn off the p...

Page 4: ...or cleaning the unit switch power off at the service panel and lock the service disconnecting means stop revent power from being switched on accidentally If the service disconnecting means cannot be...

Page 5: ...ll result Use an extinguisher ONLY if a You know you have a class ABC extinguisher and you already know how tooperate it b The fire is small and contained in the area whereit started c The fire depart...

Page 6: ...rench Sheet metalsheers Needle nose pliers Scissors to cut duct tape Duct tape Marker or pencil Level Measuring tape PARTS INCLUDED Filter spacer Filters Qty 6 pcs Hood mounting bracket Grease tunnel...

Page 7: ...king surface and bottom of the hood 28 30 D Hood height 9 8 E Cabinet height N A DIMENSIONS FOR 30 HOOD Installation The information contained herein is based on sources that we believe to be reliable...

Page 8: ...irflow exhaust use a straight run or as few elbows aspossible Vent unit to the exterior only At least two people are required for installation Remove the range hood from the carton packaging and place...

Page 9: ...operation It is recommended that the range hood be vented vertically through the roof through 8 20 3 cm round metal aluminum vent or vented horizontally through the wall through a rectangular vent me...

Page 10: ...to maximize airflow when connecting to duct provided VENTING METHODS INSTALLATIONDIAGRAMS Vent work can terminate either through the roof or wall To vent through a wall a 90 elbow may be needed This r...

Page 11: ...hort circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current Position the outlet offset so that the power cord will not interfere with the round duct...

Page 12: ...l screwdriver in order not to damage the range hood Connect and secure the 8 round metalduct referto figure4 Skip Part B below and proceed to Step2 CAUTION Make certain the range hood is secure before...

Page 13: ...k above as illustrated in figure 4 Use duct tape to make all joints secure and airtight Step 3 Drop oil tunnel into recess support near rear of hood See figure 8 To install baffle filters and stainles...

Page 14: ...again to turn off the lights CAUTION DO NOT touch the lights until switched OFF and cooled Activating Power Off Delay Function While the range hood is on and the blower is running press Power Off Dela...

Page 15: ...Sensitive Electronic Control Panel w Heat Sensor Remote Stainless Steel Baffle Filter 3W 12V LED Light Top 8 inches Round Radio Frequency Interference Protected SPECIFICATIONS Specifications3 1 In Ho...

Page 16: ...r Assembly M otor Fan Blade Protective Grill and Squirrel Cage Electrical Assembly Stainless Steel Spacer Baffle Filter Power Cord 16 1 2 3 4 BLOWER ASSEM BLY 5 No No 6 7 8 9 10 Description Descriptio...

Page 17: ...EEL FOR EXTENDED PERIODS MANY OF THESE COMPOUNDS CONTAIN CHEMICALS WHICH MAY BE HARMFUL RINSE WITH WATER AND WIPE DRY WITH A CLEAN CLOTH CLEANING THE GREASE FILTER The filters are intended to filter o...

Page 18: ...is unplugged or turn OFF breaker and make sure the lights are cool to touch Place a flat head screwdriver between light housing and hood body gently pry up the light housing and search for the metalc...

Page 19: ...connection with equipment of other manufacturers Repaired or modified by anyone other than your local reseller s authorized agents This limited warranty also does not apply to any product on which th...

Page 20: ......

Reviews: