Page 6 / 21
adeunis
®
Manage & optimize your assets & services
283, rue louis Néel 38920 CROLLES, France
Tél : +33 (0)4 76 92 07 77 E-mail : [email protected]
www.adeunis.com
Register
Size
(bytes) Base
Description
Default
value
Min-Max
Value
Comments
328
2
10
Leak threshold
(channel A)
0
0 ... 65535 Unit: pulses per hour
0: deactivated
329
2
10
Leak threshold
(channel B)
0
0 ... 65535 Unit: pulses per hour
0: deactivated
330
2
10
Number of
daily periods
under the leak
threshold
(channel A)
0
0… 1440
0: deactivated
The multiplication of this register by the
period of flow measurement must be less
than 24 hours otherwise the product will be
perpetually in alarm.
331
2
10
Number of
daily periods
under the leak
threshold
(channel B)
0
0… 1440
0: deactivated
The multiplication of this register by the
period of flow measurement must be less
than 24 hours otherwise the product will be
perpetually in alarm.
332
1
10
Scan period for
Channel A
tamper input
2
1… 255
x10 seconds
333
1
10
Tamper
detection
threshold
channel A
3
1… 255
Number of positive scans of A-channel
tamper before triggering the tamper alarm
334
1
10
Scan period for
Channel B
tamper input
2
1… 255
x10 seconds
335
1
10
Tamper
detection
threshold
channel B
3
1… 255
Number of positive scans of B-channel
tamper before triggering the tamper alarm
340
1
10
Number of
redundant
samples per
frame
0
0… 255