4.2

 

User mode 

At powerup the device will immediately start operating and the LEDs will start blinking. During normal operation the device will 
transmit LoRa frames periodically (every 20s by default), but the user can also trigger a transmission manually by pressing button 
1 (BTN1) or by shaking the device and triggering its accelerometer. If a GPS coordinate is available, it is included in the payload.  
 
The following table describes the LEDs operation: 
 

Phase description 

LED1 

LED2 

Startup:  

In personalization mode, the device 

checks if a device address is present 

 

In OTAA mode, the devices waits for the 

network to provide the necessary keys 

Steady Red & Green 

Dedicated to GPS Operation 

 

Blink Red = GPS not synchronized 

Blink Green = GPS synchronized 

OFF = GPS OFF or in sleep mode 

The Device address was found / The 

keys were received 

Green for 3s then turn off 

Execution of a LoRa cycle 

Steady Red 

At the end of a LoRa cycle, an answer 

was received 

Blinks green 5 times, then turns off 

At the end of a LoRa cycle, no answer 

was received 

Turns off 

Between two LoRa cycles 

Off 

 

The LoRa frames transmitted to the network will be available to the user through the operator’s back

-end. 

 

Summary of Contents for LoRaWAN Demonstrator

Page 1: ...Demonstrator By Adeunis RF Provider Edition User guide version V1 2 Software version V1 1 ADEUNIS RF 283 rue Louis N el Parc Technologique Pr Roux 38920 CROLLES France Tel 33 0 4 76 92 07 77 Fax 33 0...

Page 2: ...formation contained herein Reproduction use or disclosure to third parties without express permission is strictly prohibited Copyright 2012 Adeunis RF Adeunis RF is a registered trademark in the EU an...

Page 3: ...ich this declaration refers conform with the relevant standards or other standardising documents x EN 300 220 1 v2 4 1 2012 05 x EN 60950 1 2001 A11 2004 x EN 301 489 1 v1 8 1 2008 04 x EN 301 489 3 v...

Page 4: ...chen Union 9 2 DEVICE OVERVIEW 10 2 1 Form factor 10 2 2 Technical specifications 10 3 CHARGING THE DEMONSTRATOR 11 4 USING THE DEMONSTRATOR 12 4 1 LoRa testing mode 12 4 2 User mode 13 5 DEVICE CONFI...

Page 5: ...ion V1 2 page 5 24 Figure 1 Demonstrator physical description 10 Figure 2 Product during charge 11 Figure 3 Product when charge is completed 11 Figure 4 using the device 12 Figure 5 Device as a serial...

Page 6: ...rams are the exclusive property of ADEUNIS RF Any transfer granting of licences to a third party leasing hire transport copying editing translation modification into another programming language or re...

Page 7: ...orches etc x The device must not be exposed to aggressive chemical agents or solvents likely to damage the plastic or corrode the metal parts x Install your device close to its DC power supply Disposa...

Page 8: ...erden k nnten Die Bezeichnungen der Programme sowie alle Urheberrechte zu den Programmen sind das alleinige Eigentum der ADEUNIS RF Jede bertragung Gew hrung von Lizenzen an einen Dritten Leasingverga...

Page 9: ...ls der Einwirkung von aggressiven Chemikalien oder L semittel ausgesetzt werden die geeignet sein k nnten den Kunststoff zu besch digen oder die Metallteile zu korrodieren x Stellen Sie Ihr Ger t in d...

Page 10: ...ensor Figure 1 Demonstrator physical description 2 2 Technical specifications Technical specifications Communication LoRaWAN protocol LoRa Modulation Module configuration Through AT commands Radio dat...

Page 11: ...ch is on the OFF position this behavior is similar to the one of mobile phones The product can still be used while it s charging During the charging process the charge state indicator is steady red Wh...

Page 12: ...is reserved to the ROOT level of authorization This level can be reached by using the command ATT63 ROOT Refer to chapter 5 2 for details of the command The device must be place in command mode using...

Page 13: ...hase description LED1 LED2 Startup In personalization mode the device checks if a device address is present In OTAA mode the devices waits for the network to provide the necessary keys Steady Red Gree...

Page 14: ...will be recognized as a serial peripheral creation of a virtual serial COM port 5 1 Serial link parameters Parameter Value Speed 115200 bps Parity None Bits 8 Stop bit 1 When plugged to a PC the devi...

Page 15: ...the command is rejected x Ends by CR LF The following commands are available Command Description Reply example FF FF FF FF Entry in command mode CM cr lf AT V Displays the firmware version LORA DEMO...

Page 16: ...the air activation OTAA In either case the DEV EUI which is essentially a MAC address is provided by the end point manufacturer in this case ADEUNIS 5 3 1 1 Personalization mode In personalization mod...

Page 17: ...NWK_SKEY MID MSB 0 224 LORA NWK_SKEY MID LSB 0 225 LORA NWK_SKEY LSB 0 226 LORA APP_SKEY MSB 0 227 LORA APP_SKEY MID MSB 0 228 LORA APP_SKEY MID LSB 0 229 LORA APP_SKEY LSB 0 281 Device Address 0 5 3...

Page 18: ...transmitted by the network during OTAA the CF list values will prevail By default channels 0 2 use the LoRaWAN parameters and channels 3 6 are deactivated If a register contains other values than 0 o...

Page 19: ...register S201 see 5 3 7 Note on ADRACKReq When the device has transmitted multiple frames but hasn t received any downlink whether it s a generic downlink or an ACQ from the server enabling ADRACKReq...

Page 20: ...meter The device s accelerometer is configured by default to trigger whenever the device is shaken by hand However its configuration can be modified to suit the user s application Two parameters can b...

Page 21: ...s stationary or walking pace with good satellite visibility Note 1 As periodic mode is less powerful we highly recommend a startup time 5min so that the GPS can synchronize and acquire the ephemeris a...

Page 22: ...al part of Latitude s minutes tenths of minutes b 3 0 BCD coding of the decimal part of Latitude s minutes hundredths of minutes 6 b 7 4 BCD coding of the decimal part of Latitude s minutes thousandth...

Page 23: ...act a negative number as the RSSI will saturate above 20dBm For example if the value is 100 this means that the RSSI is 100 dBm x The SNR value is a signed value in two s complement ranging from 128 t...

Reviews: