FR
EN
LoRaWAN 863-870 PULSE IP68 - Guide utilisateur / User guide V4.0.0
51
Page
of 58
2.4.6
Transmitting a Daily Frame
The product transmits every 24 hours a daily frame (0x30) according to the following diagram:
The transmission period of the daily frame is fixed (24 hours) and not configurable.
Product in
standby
Initialization of
min and max flow
rates
Period
of 24h
reached
?
Yes
Send frame 0x30
Initialization of
alarm states
No
Eg:
Register
Value encoding
Value
Result
S320
Hexadecimal
0x39
Channel A :
• Activated
•
Meter other than gas
•
Tamper input activated
Channel B :
• Activated
•
Gas meter
•
Tamper input disabled
S332
Decimal
2
Scan period for A-channel tamper input is 2x10s
= 20s
S333
Decimal
3
Tamper detection threshold for A-channel = 3
(positive scans of B-channel tamper before trig-
gering the tamper alarm)
S334
Decimal
2
Scan period for B-channel tamper input is 2x10s
= 20s
S335
Decimal
3
Tamper detection threshold for B-channel = 3
(positive scans of B-channel tamper before trig-
gering the tamper alarm)