ADEUNIS RF - WMBUS GPRS GATEWAY USER GUIDE V2.5.1
16
Page
of 19
Example for one wmbus reception per hour and 1 file transfer per day at midnight every day:
<cal dd=”7FFFFFFF” hh=”0” tx=”1”/>
<cal dd=”7FFFFFFF” hh=”1” tx=”0”/>
<cal dd=”7FFFFFFF” hh=”2” tx=”0”/>
<cal dd=”7FFFFFFF” hh=”3” tx=”0”/>
<cal dd=”7FFFFFFF” hh=”4” tx=”0”/>
<cal dd=”7FFFFFFF” hh=”5” tx=”0”/>
…
…
…
<cal dd=”7FFFFFFF” hh=”17” tx=”0”/>
<cal dd=”7FFFFFFF” hh=”18” tx=”0”/>
<cal dd=”7FFFFFFF” hh=”19” tx=”0”/>
<cal dd=”7FFFFFFF” hh=”20” tx=”0”/>
<cal dd=”7FFFFFFF” hh=”21” tx=”0”/>
<cal dd=”7FFFFFFF” hh=”22” tx=”0”/>
<cal dd=”7FFFFFFF” hh=”23” tx=”0”/>
Operation mode parameters
Description
Comments
Park
(state = 1)
No parameter -> The gateway return to an unconnected mode. The
gateway must be reactivated with a magnet.
Operation
(state = 2)
Normal mode. No specific parameters
Installation
(state = 2 + parameters inst_d-inst_p)
Time period : min 1 – max : 65535 (in minute)
If value 0 -> Installation mode inactivated
Min : 1 – max : 1440 (in minute)
Description
Parameter
Format
Scan period
<syst inst_d=””/>
Num : 1-65535
Period between scan
<syst indt_p=””/>
Num : 1 -1440
Running mode
<syst state=””/>
1 or 2
See note(1)
5.1.2 Upgrade File
5.1.2.1
File name
Type
Format
SerialPart
NamePart
Example
XML File
SerialPart_NamePart.xml
Numerical
(Gateway Serial Number)
upgrade
02
08001A
_upgrade.xml
The Name part contain the serial number of the g other number
For the gateway K
08001A
->Take the serial number without the first letter (K)
5.1.2.2
File contents
The following information shows an example of a configuration XML file. The
colored
zones can be modified by user.
<config version=”
1
” file=”
config_1.xml
”/>
<firmware version=”
3.0.0
” file=”
amrgateway_3.0.0.tar
”/>