Installing the Robot Solenoid Kit
Adept Cobra i600/i800 Robot User’s Guide, Rev E
67
Figure 5-9. Solenoid Mounting Bracket with Connector and Spare Air Line
4. Cut and discard the cable ties holding the spare air line at the top of the mounting
bracket. Move the air line away to facilitate the mounting of the solenoid
manifold (see
5. Mount the solenoid manifold onto the bracket using the supplied M3 x 25 mm
6. Insert the spare air line into the air intake coupling of the solenoid manifold.
Make sure the air line is pushed in all the way and secured in place by the intake
coupling. Confirm by pulling on the air line.
NOTE:
If you are installing a Solenoid Kit on a Cleanroom or IP-65 robot,
the spare air line is used for a different purpose in those robots. You will
have to provide a piece of 6 mm tubing to run from one of the 6 mm user
airlines at the Joint 2 cover to the air intake coupling mentioned above.
7. Plug the connector plug into the female connector jack (marked SOLND) on the
bracket.
8. Use cable ties, as needed, to secure the air line to the bracket.
Pem nuts to mount the
solenoid manifold
Connector for the
solenoid valves
Spare air line
Summary of Contents for Adept Cobra i600
Page 1: ...Adept Cobra i600 i800 Robot User s Guide ...
Page 2: ......
Page 10: ......
Page 14: ......
Page 34: ......
Page 56: ...Chapter 4 System Installation 56 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 76: ...Chapter 5 Optional Equipment Installation 76 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 104: ...Chapter 6 System Operation 104 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 116: ...Chapter 7 Maintenance 116 Adept Cobra i600 i800 Robot User s Guide Rev E ...
Page 147: ...Index Adept Cobra i600 i800 Robot User s Guide Rev E 147 ...
Page 148: ......
Page 149: ......
Page 150: ...5960 Inglewood Drive Pleasanton CA 94588 925 245 3400 P N 03589 000 Rev E ...