background image

 

9

Aid”. Press the key “          ”, and the screen display these seven alarm types in order. (Note: 
all the zones will be default to be alarm type “Steal” if you don’t do this program) 

(2) Set the “Steal” alarm type 

  Demonstration: set the zones from 1

st

 to 5

th

, 10

th

 and 12

th

 zones into “Steal” 

 Operation steps: press the key “       ” continuously, and the screen displays          .   

   

 

and then input   

                                                                                                                    . 

                                                        .  and  the  alarm  panel  sounds  a  long  indicator  to 

inform that you have set the alarm type successfully. When alarming, the screen will 
display the alarming zone and their alarm types 

(3) Set other alarm type 

Similarly, you can press the key “          ” continuously and when the screen displays the 
alarm types, and you input the zones and press the key “            ”. And then you can set the 
alarm type successfully. (Note: the zone number should be 2-digit; if not, please add “0” 
ahead) 

(4) Cancel the alarm type: press the key “          ”, and when the screen display the alarm type 

which you want to cancel, please input         .The host sounds a indicator voice to 
inform that you have cancelled it. 

 

7. Prerecord the alarm language segment 

(1)

 

Turn on the “program” switch and press the “      ” key without releasing. When 

seeing that the recording indicator shining, you can aim at the microphone to prerecord 
20-second alarm language segment. On prerecording the language, please turn off the 
“Program” switch. 

          (2) Replay recorded segments: press the “            ” key and you hear the segment that you 

prerecorded. If the segment is not clear, you can record once again and the new one will 
automatically cover the former one.   

          (3) Delete the recorded segment: press the “            ” keys and the recorded segment will be 

deleted. 

     

 

8. Match code between the detector and the host

 

(Note: this way is suitable for the 

add-on detectors, and there is no need for the original detectors to rematch code with host ) 

 
 
 

 

 
 
 
 
 
 
 

PROG

.

Zone

Steal

1

0

0

2

0

3

0

0

4

5

1

0

1

2

Enter

Enter

8

H

L

H

L

A

n

te

nn

a

Address code 

     jum per

Indicator

Zone code 

  jumper

Code-matching

Working mode

On

Off

Power

Infrared tube

Sensitivity

H

M

L

The structure of Circuit Board of Detector

Play

www.best-china-security-supplies.com

Summary of Contents for TI110B1

Page 1: ...receiving center to form a comprehensive monitoring system When alarming the computer of the center can show the alarm detailed information like alarm place address location time and police resource d...

Page 2: ...m cell phone Meantime it becomes the No 0 group of telephone number And other alarm receiving numbers and other functions only can be set by this program cell phone Note the No 0 group of telephone nu...

Page 3: ...888888 71 XXXXX X and send it to the GSM SIM card And the 1st number is stored successfully The 1st number can receive the alarm call but it cannot receive the alarm SMS Similarly you can use this way...

Page 4: ...roup of number 6 Alarm Location This GSM alarm system can inform you of the alarm location in the form of SMS when alarming and you are allowed to prestore check cancel all the alarm location 1 Store...

Page 5: ...ss Center Alarm Location Arm 9 Arm Disarm by Cell Phone You are allowed to use cell phone or fixed telephone to dial the GSM SIM card And when you hear di indicator voice please input XXXX password An...

Page 6: ...ers stored in the GSM SIM card when the fixed telephone works well And meantime please note that you make sure that the Edit switch be turn on before starting programming 1 Operation Notice 1 Turn on...

Page 7: ...telephone is 22379620 518 after dialing 22379620 pause 3 seconds and then dial 518 4 Modify and delete telephone number If the telephone number you stored is wrong or you want to store a new one you c...

Page 8: ...you that you have set all the zones into Arm Away successfully c Set Emergency Zone Demonstration set the 9th and 10th zone into Emergency Zone Operation steps press the key repeat and the screen disp...

Page 9: ...host sounds a indicator voice to inform that you have cancelled it 7 Prerecord the alarm language segment 1 Turn on the program switch and press the key without releasing When seeing that the recordin...

Page 10: ...e control 1 Please press continually the key till the light of all the defense area and press the key on the remote control without releasing and then press the key of the alarm panel You will hear a...

Page 11: ...and the screen displays Then input The alarm panel sounds a long indicator voice which means that you have set it successfully 2 Cancel the timing arm disarm time Press the key once and the screen di...

Page 12: ...nd then press and you can hear a long indicator voice which means that you have stored the number successfully 2 Report to the center when arming Press the button continuously till the screen displays...

Page 13: ...of Disarm On checking press the key 3 Check the Enter Delay and Exit Delay Please press the key once and the LCD will display six digits among which the first 3 digits is Enter Delay second and the la...

Page 14: ...mmediately or don t disarm the host and the host will continue to next one in order and circulately till the host is disarmed Note every number will be dialed three times And if you want the alarm pan...

Page 15: ...the install location should be near the telephone line and the power socket When it being installed on the wall please mark the screw hole first on the wall for correct installation 2 Optional accesso...

Page 16: ...here are Edit Power Alarm Volume Alarm Mute switches after installation and debugging Technical Parameter z GSM module TC35i or TC35 Industrial grade module z GSM frequency EGSM 900 and GSM 1800 z GSM...

Page 17: ...top alarm 10 minutes later 8 With limited capacity the backup battery is for the emergency And the host should be supplied by power AC mainly 9 The remote control is forbidden being drop heavily or be...

Page 18: ...stance between the magnetic panel and the transmitter is too far Make sure the distance between the transmitter and magnetic panel is within 1cm Alarm failure when the indicator of magnetic contact st...

Reviews: