background image

Summary of Contents for Alpha Vista 5130XT

Page 1: ...INSTALLATION INSTRUCTIONS 7 ADEMCO ALPHA VISTA NO 5130XT SECURITY SYSTEM I N3122 3 3 89 Previous Menu...

Page 2: ......

Page 3: ...Diagram 7 Diagram 8 Diagram 9 Diagram 10 Summary of Connections 17 24 Pin Connector with Flying Leads 5130XT Field Wiring interface 18 KeyswitchWiring 19 Installing the Digital Communication interface...

Page 4: ...s of a paflic ular installation or installation company following the instructions pro vided in the programming section of this manual factory programmed values are also shown there This system also c...

Page 5: ...back the internally stored central station service phone number 3 Data Encryption Data passed between the central station and the No 5130XT ISencrypted for security so that it is very difficult for a...

Page 6: ...e reported 2 After the5130XT and the 699 or PC have established valid communi cation each console will become inactive The 5130XT will resume the normal security functions including responding to faul...

Page 7: ...m Interior Follower Delayed alarm only if the Entry Extt zone IS faulted first otherwise produces an instant alarm Assigned to zone covering an area such as a foyer or lobby through which one must pas...

Page 8: ...ched LCD display A system wide EEPROM defined number of alarm reports for this zone will be allowed to be transmitted swinger suppression in one armed period Restorals will be sent when the zone is re...

Page 9: ...to be sequentially displayed No communicator reperk will be initiated Type 5 TyfJs 6 BURGLARY PERIMETER TROUBLE BY DAY ALARM BY NIGHT During the disarmed state day faulting the zone will initiate a tr...

Page 10: ...stored for a time greater than its physical response time less than 1 second FIRE ZONE Opens in this zone will result in troubles Shorts will result in alarms Note Zone 1 will support 2 wire Smoke Det...

Page 11: ...TYPE 1 2 3 4 5 6 7 8 9 10 II 12 13 14 15 16 W 1w t ENTRY EXIT Delay 41 Burglary 2 ENTRY EXIT Delay H2 Burglary 3 PERIMETER Burglary 4 INTERIOR FOLLOWER Burglary 5 TROUBLE BY DAY ALARM BY NIGHT Burglar...

Page 12: ...e the No 4208 to obtain zones 10 17 that product s DIP switches must be set as follows 2 3 4 5 nom as If set for sensor numbers 113 120 as cited in the instructions for the No 4208 Installation instru...

Page 13: ...previously up to thirteen secondary codes can be assigned to users 3 through 15 The configuration m Application 1 shows that secon dary or temporary codes may be assigned by the primary user user 2 t...

Page 14: ...00 s r 43 l c DU User 4 Note All codes can Arm Disarm the System User 3 can assign secondary codes to users 4 142 1A secondary temporary code is assigned as follows User 2 Master Code CODE key User 0...

Page 15: ...d disarm the system This code although actually a secondary code will serve as a master security code for the apartment owner etc since user 3 is the primary user of the system in this application A s...

Page 16: ...nnector is the earth around lead see Note Optional 30 ft 9 m and 15 ft 46 m wiring harnesses with a 24 pin Table C Connect this lead to a suitable earth ground a metallic cold connector at one end are...

Page 17: ...op s sTANc 3 0 s ACtwo NO 2 0 lIm2 s y w EOLR TO Z WERETUEU PIN Z70R8 I 3 m A ypy s TO ZCWE mm P 2 7 ma I o 0 TO 0 4 0 II p I 0s 0 SOW S C CS O 0 7 R 12VDC t I TO BLACK P N 101 A 0 NOLo s ASa Pmr c m...

Page 18: ...itch may be used for remote arming and disarm ing this is an installer programmed option A normally open momentary switch is connected across Zone 7 which must be given up as a protection zone A momen...

Page 19: ...PER I SWITCH IN C I wHITE vlo LET Pl N16 4 I I TO FLYING LEADS ON 24 PIN INTERFACE I LOCK CONNECTOR SEE DIAG 1 1 SWITCH N O 1 ZONE RETURN PIN 2 7 OR 6 I I NOTE I SUGGESTED PARTS FOR REMOTE KEYSWITCH I...

Page 20: ...lace The other connector is connected to the 5130XT Control via a straight male to male 10 pin adapter supplied Specific information regarding the use of the adapter and connection to the 5130XT Contr...

Page 21: ...the Communication Interface Board to the Control board as follows Guide the adapter pins on the Communication board into the interface pin holes on the Control board simultaneously allow ing the ends...

Page 22: ...ped connector pins on the 4171 XT board and 12 respectively on the 4208 Zone Expander For information on Position the 4152LM board over the 4171 XT board so that these pins wire usage etc refer to a p...

Page 23: ...can shadow the display For optimum viewing the control should also be mounted so that the display is below eye level to ensure that the system s user will look down at the display In the event that th...

Page 24: ...r connecting wires to the terminal block as follows referring also to Diagram 6 Communication Interface Wire Board Terminal Assignment 1 Ground Start 2 Incoming Phone 3 Incoming Phone 4 Handset Ring 5...

Page 25: ...TRAIGHT 1 INCOMING IF USEO l PIN PHONE LINE RING MA LE TC MALE RING ADAPTER r HANDSET r TIP L L GROUND START NOT USABLE IN A UL INSTALLATION J j REAR OF CONTROL BLACK LEAO BACK COVER REMOVED PI N 1 TH...

Page 26: ...een made too large over cutting The Con trol fits into the recess in the trim ring which will extend 1 3 cm beyond the Control front panel andthus cover any open ing that might otherwise be visible as...

Page 27: ...eviously Insulated soiderless wire splices such as Ademco No 311 may be used for splicing Check ail wire connection carefully before splicing Note If the optional 15 ft 4 6 m or 30 ft 9 m wiring harne...

Page 28: ...hits the clip stop and will then draw the Control forward B Continue turning the screw until the Control is flush against the wall Then making sure that the Control is straight tighten the screw furth...

Page 29: ...PRING NOTE CURVED END I CLIP STOP B CONTROL w IF SHEETROCK IS TOO THICK BREAK OFF THE SCORED WING NOTE 4 5 16 11 cm H X 7 3 4 20 cm W WALL OPENING IS REQUIRED FOR FLUSH MOUNTING Diagram 9 FLUSH MOUNTI...

Page 30: ...ogramming from the Control note the following 1 Enter the Programming mode by simultaneously depressing the and keys within 30 seconds after power is applied to the Con trol or subsequently by keying...

Page 31: ...STORE FACTORY PROGRAM SETTINGS 97 see Factory Programming Table ENTER ZONE DESCRIPTION AND INSTALLER MESSAGE PROGRAMMING MODE 93 SPECIAL MESSAGES FC FIELD CODE ERROR program entry mistake re enter the...

Page 32: ...Function Factory Programmed Value Elm EEI EHzI EIEI Elm EIEI IIIEI Em Em Em EIEI EIEI Fire Perimeter Burglary Interior Follower Burglary Trouble by Day Alarm by Night Burg Interior Delay Burglary 24 h...

Page 33: ...5 ASSIGN RESPONSE TYPE FORVARIOUS KEY PAD PANICS AND ZONE EXPANDER WIRING SUPERVISION Factory Programmed Value m EE m HE m IIlm EIEI Elm Em Em 08 NOT USED 09 ENTRY DELAY 1 III III seconds 10 EXIT DELA...

Page 34: ...patibility Disable Disable Disable o Entry of zero mandatory Enable 20 NOT USED o Entry of zero mandatory 21 DISABLE FIRE o No TIME OUT 22 NOT USED 23 24 25 26 27 28 29 30 31 MULTIPLE ALARMS n 1 Yes T...

Page 35: ...e Bypass enabled n 51 Remote Disarm enabled Address Function 6 7 8 38 INHIBIT BYPASS OF ZONE 39 OPEN CLOSE REPORTING ENABLE BY USER CODE 40 REPROGRAM I DOWNLOAD ATTEMPT REPORT 41 EOLR DISABLE Zones 2...

Page 36: ...B F reporting DUAL REPORTING n o No OPEN CLOSE REPORTING ENABLE Dmm BY USER CODE am disabled for Users 2 8 Address Function 53 54 55 56 57 58 59 60 61 4 2 ZONE EXpANDED FORMAT SELECTION 4 2 ZONE FORMA...

Page 37: ...med Value Em Em Eml Em 8EIEI 62 CHANNEL ASSIGNED o Em EACH ZONE CONT D 21111111 311HII Em 5EIEI EEl Zeroes for zones 9 16 no code reported Address Function Elm 8EIEI 63 CHANNEL ASSIGNED TO EACH ZONE C...

Page 38: ...l zeroes in 8 locations s me as Address 61 Duress Short in Wiring to Zone Expander displays 97 1 panic displays 95 3 Panic displays 96 Panic displays 99 Zeroes for channels 1 8 no code reported Addres...

Page 39: ...EIEI EIEI Elm EIEI Em mIl 1 Em Em 2EIEI Not Used All zeroes no codes reported All zeroes no codes reported EIIII Enable all EIEI Zone 5 enabled all others disabled Enable all AL Zeroes for zones 1 8 T...

Page 40: ...ctory Programmed Value lIlm AL EmTR EmBy noco e Zeroes for zone 17 m A RE reported EHIZITRRE EEIBYRE EIEIAL EIEITR ElmBy El El AL Zeroes for keypad panics and for zone expander wiring supervisory no c...

Page 41: ...9 16 ID DIGIT 2nd digit El El J 6 EIEI ElEl 2EIEI 3Eml EHII EHII 6 EIEI Address Function Factory Programmed Value 78 4 2 EXPANDED 17 III D oca ion Zeroes for zone 17 FORMAT ZONE and the other seven 17...

Page 42: ...tory Programmed Value EIEI EIEI Elm EIEI Elm Em EIEI EIEI EIEI EIEI Duress Short n Wiring to Zone Expander 1 panic 3 Panic Panic Zeroes no codes reported in all 10 locations Address Function 81 4 2 EX...

Page 43: ...y Programmed Value 84 ADEMCO HIGH SPEED n o No REPORTING ON 800 WATS LINES 85 ENABLE 5130XT 1 o Disabled FOR SUBZONING 86 ZONE EXPANDER TYPE SELECTION 87 ENTRY WARNING SELECTION 88 BURGLARY ALARM COMM...

Page 44: ...its O 9 entry of all 4 IS mandatory Use of a 9 In last position Inhibits the Ambush feature ASSIGN RESPONSE O2 0 Zonel COMMENTS Enter 2 dlglfs 00 10 in each field TYPES FOR ZONES 0 Zone2 use one of th...

Page 45: ...digit response types see Address O2 for types ASSIGN RESPONSE O4 1 U Zone17 TYPE FOR ZONE 17 mm Jmzl mm Zeroes to be entered 5ED EXPANDER WIRING SUPERVISORY AND FOR KEYPAD PANICS 05 IIml p IFIl q mmZe...

Page 46: ...96 rln COMMENTS Defines the time period between a fault occurring in a zone to which Entry Delay 1 has been assigned and the time when the alarm will sound UL 1023 Household Burglary usage permits a m...

Page 47: ...tiply by 15 seconds to determine time delay O 225 seconds available ALARM SOUNDER DURATION 3 COMMENTS Defines the length of time an external or the control s alarm sounder will sound for all audible a...

Page 48: ...rwise enter O NOT USED 18 MUSTBEZERO CONTROL ALARM 19 SOUNDER DISABLE COMMENTS Enter 1 to disable the built in sounder at the control and remote consoles during a burglary otherwise enter O NOT USED 2...

Page 49: ...ide expansion zones Enter O to enable tamper detection opening of the4190WH case 26 26 27 COMMENTS Only applicable if Ademco High Speed Format is selected Enter 1 to disable duress reporting or O to e...

Page 50: ...led or 1 enabled TOUCH TONE OR 3O ROTARY DIAL COMMENTS Permits selection of the type of dialing to be used Enter 1 for Touch Tone O for Rotary PABX ACCESS 31 CODE o l 0 o COMMENTS If not required ente...

Page 51: ...igit Erase the field by entering 32 COMMENTS Enter up to 12 digits 0 9 Do not fill unused spaces Erase the field by entering 33 NOTE Back up reporling 8 calls are made to the secondary phone number if...

Page 52: ...BLES 2 1 System Shutdown 3 Not Used 4 Remote Bypass 5 Remote Disarm 6 Remote Arm 7 Upload Program COMMENTS Each of the various remote from the Central Station functions can either be enabled or disabl...

Page 53: ...E RESISTOR SUPER VISION ON WIRED ZONES 2 8 39 LHXICIUEII COMMENTS Enter O disable or 1 enable Determines which user codes will send open close reports 40 1 c1 LOCAL REPROGRAM DOWNLOAD ATTEMPT REPORT 1...

Page 54: ...an be confused with dial lone and premature dialing resuhs Enter 1 Dial Tone detection or O Dial Tone Detection disable 1 COMMENTS Only applicable If central station initiated downloading will be used...

Page 55: ...s 40 67 and 66 and the alarm reports desired must be selected in Addresses 65 and 66 47 1 COMMENTS Central station receiver Acknowledge wait time for secondary phone number Enter O 30 seconds or 1 60...

Page 56: ...nabled to permit use of installer code to enter Programmmg mode COMMENTS Enter 1 if 4 2 reporting by zone for a zone expanded system is desired enter O if a non expanded zone configuration is being us...

Page 57: ...s s o Sss s c Sss s x SSS S Te Sss s P SSS S M SSS S R 3 j 4 l Expanded SSS S A AAA A Ch SSS S T T Ch SSS S B BBB B Ch SSS S E EEE E Ac SSS S L LLL L LB Sss s o 000 0 u Sss s c ccc c u Sss s x SSS S T...

Page 58: ...ZONES assigned to CHANNELS 1 through 8 in Addresses 61 through 64 will a pear in Channels 1 through 8 4 5 6 7 9 CLOSING REPORT in the previous 7 or 8 channels 7 if expanded opening closing reporting i...

Page 59: ...s an opening Subscriber Channel Number Identification f23456769 Message 0135 122222222 4 After transmission of Example 3 subscriber 0135 sends a closing Subscriber Channel Number Identiflcatlon 123456...

Page 60: ...ot applicable to Program Tamper and Power Up Reset 9 At Subscriber 5890 zone 12 assigned to channel 13 goes into alarm and zone 11 assigned to channel 11 which has previously reported an alarm has res...

Page 61: ...and inarestore report when all bypasses are removed Fire and priority zones cannot be bypassed When Expanded is selected the channel is transmitted in the last position of the 2nd transmission line or...

Page 62: ...ssion line if 4 2 Format is used NOTE Selection applies to both primary and secondary phone numbers CHANNEL ASSIGNED TO 6 n one 1 LUNG 3 0ne2 2 I Elcl zone Llnzone Elnzone nclzone FUNCTION ADDRESS nnz...

Page 63: ...El used El El used COMMENTS Enter all channel IDs as double digits Same as Address 61 Disable 00 no channel reporting CHANNEL ASSIGNED TO EACH ZONE used CON T mm used El El otused n Uress Eln anic cm...

Page 64: ...8 13 D 04 4 09 9 14 E 05 5 10 0 15 F NOTE Non zero codes must be entered when traditional Ademco High Speed for mat is used FUNCTION ADDRESS ALARM RE PORTING CODES ASSIGNED TO nn EACH CHANNEL OOOO 00...

Page 65: ...OTusED n CANCEL CODEZ COMMENTS Enter all codes as double digits see Address 65 Disable 00 no report NOTE Non zero codes must be entered when traditional Ademco High Speed for mat is used When 4 2 by...

Page 66: ...at a 2 digit reporting code is utilized let us discuss how zones 1 17 Duress Zone Expander Supervisory and the 3 keypad panics 1 3 and can be coded The recurring theme of the follow ing information is...

Page 67: ...EE EF English language on the Ademco 685 Digital Receiver should not be us d for m st o these reports 5 Note that B and Care not used for leading digits in the above table It is suggested that these...

Page 68: ...or zones 9 16 Enter all reporting codes as double digits see Address 65 Disable 00 no code reporting FUNCTION ADDRESS 4 2 EXPANDED FOR MAT ZONE 17 EVENT DIGIT Ist digit of 74 ALARM reporting code ITRO...

Page 69: ...rious keypad panics duress 1 and 3 and for supervision of the wiring for short circuits to the zone expander Enter all reporting codes as double digits see Address 65 Disable 00 no code reporting FUNC...

Page 70: ...g codes as double digits 4 2 EXPANDED 79 see Address 65 Disable 00 FORMAT KEYPAD no code reporting PANICSIZONE EXPANDER WIRING 78 17 n SUPERVISORY ID DIGIT 2nd digit Em IImI of repo hing code EmI Em E...

Page 71: ...RESTORE REPORT 2nd digit n TEST REPORT 1st digit O TEST REPORT 2nd digit COMMENTS Enter all reporting codes as double digits see Address 65 Disable 00 no code reporting if both 1st and 2nd digits are...

Page 72: ...STORE REPORT 2nd digit o O Not d z r e to be En j u 0 Not used Zeroes to be Entered n CANCEL REPORT 1st dlglt oCANCEL REPORT 2nd digit COMMENTS Power Up is transmitted after a power reset or after exi...

Page 73: ...diately upon exiting 01 31 represents the range in hours that can be selected ADEMCO HIGH SPEED 84 FORMAT USED ON WATS LINES 1 COMMENTS Enter 1 if Ademco High Speed Format either traditional or 4 2 ve...

Page 74: ...an be pro 1 grammed into the system Each description maybe composed of a com 2 bination of words up to a maximum of 3 that can be selected from a vocabulary of approximately 220 words stored in memory...

Page 75: ...3 for it in the display repeat step 5 for that word to advance through the available words until the word BACK is 7 When all desired words have been entered press key 6 to store displayed in memory 5...

Page 76: ...ELLAR DRIVEWAY GARAGE CENTRAL DRUG GAS CIRCUIT DUCT GATE CLIP GLASS CLOSED EAST GUEST COIN ELECTRIC GUN COLD EMERGENCY COATROOM ENTRY HALL COLLECTION EQUIPMENT HEAT COMBUSTION EXECUTIVE HIGH COMPUTER...

Page 77: ...OP SHORT SHOW SIDE SKYLIGHT SLIDING SMOKE SONIC SONS SOUTH SPRINKLER STAMP STATION STEREO STORE STORAGE STORY STRESS STRIKE SUMP SUPERVISED SUPERVISION SWIMMING SWITCH TAMPER TAPE TELCO TELEPHONE TELL...

Page 78: ...ve the custom word s and return to the ED display The custom word or string of words will be auto matically added to the factory provided vocabulary at the end the group of words beginning with the sa...

Page 79: ...n off the system is operating on the back up battery only at this time Note 1 The system will not enter the TEST mode if the battery voltage is too low if the battery is not connected or if any commun...

Page 80: ...to account when making this adjustment An abbreviated User s Manual is stored in memory and can be displayed text are displayed at a time This function is available when the system by simply pressing...

Page 81: ...n expiration of the 10 day period all history is automatically erased and the alarm memory will reset However the 10 day cycle will start again only when the next event occurs Recall by service person...

Page 82: ...e board out away from the three small plastic clasps on the other side The two fuses are located on the underside of the main circuit board in the positions shown in Diagram 10 Make sure that the fuse...

Page 83: ...FUSES LOCATED ON UNDERSIDE OF CONTROL BOARD BENEATH 24 PIN INTERFACE wiimo ch41si Y4 cLArps 3THEsiDE STIC 9 24 REPLACED REMOT KEYPAD VIEW A INTERFACE m FLEXIBLE PLASTIC CLASPS 2 THIS SIDE Diagram 10...

Page 84: ...mote ALPHA VISTA Console Remote VISTA Console Remote Keypad Relay Module 2 8 amp rated SPDT contacts with con tact protection fuse Plug in 24 position terminal block Flush mount kit for No 4131 Batter...

Page 85: ...wire runs to the control communicator Plug the control communicator into a different outlet so that it and the receiver are on different branch circuits If necessary the user should consult the dealer...

Page 86: ...or non UL usage 2 5 Hours with 200 mA standby current load 5 Hours with no external current load 1 2AH battery used Battery Fuse 2A SIO BIO Ademco No 90 24 Auxiliary Power 0 5 A Ademco No 90 25 4171XT...

Page 87: ...AY Keypad Output 5 GREEN Keypad Output Red LED Arm ing status 6 BLUE Keypad Output Green LED Ready status 7 YELLOW Keypad Output 8 BROWN 5 VDC at 20mA Input Power 9 VIOLET Piezo Sounder Input 10 ORANG...

Page 88: ...ol is secured to these flanges with the two self tapping screws supplied Position the Control with back cover removed in the opening and secure as follows referring to Diagram A 4 On the left hand sid...

Page 89: ...e terminal blocks shown in Diagram B which are used in place of splices Instructions for connection of the optional Remote Keypad and installa tion and wiring of the digital communication interface bo...

Page 90: ...ZONE 5 WHTIBLUE ZONE6 WHTNIOLET 1 ZONE 7 TB2 GRAY 3 ZONE RETURN WHTIGRAY ZONE 8 WHTIBLACK ZONE 9 REDIYELLOW ZONE 1 WHEN 2 wIRE SMOKE OETECTORS ARE USED 6R0wN ExT ALARM SOUNDER REDlSl_4CK AUWREMOTE CO...

Page 91: ...vide early warning for a variety of reasons in as many as O of all fires according to data published by the Federal Emergency Management Agency Some of the reasons smoke detectors used in conjunction...

Page 92: ...y a stereo radio air conditioner or other appliances or by passing traffic Finally alarm warning devices however loud may not warn hearing impaired people or waken deep sleepers Telephone lines needed...

Page 93: ...L PURCHASE IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANIY EXPRESS OR IMPLIED OR UPON ANY OTHER BASIS OF LIABILITY WHAT...

Page 94: ......

Page 95: ......

Page 96: ...ALARM DEVICE MANUFACTURING CO A DIVISION OF PITTWAY CORPORATION 165 Eileen Way Syosset New York 11791 N31 22 3 3 89 Copyright 1989 PITTWAY CORPORATION...

Reviews: