SETTING THE KEYPAD ADDRESS 

The keypad address must be set according to the control 
panel being used (refer to the individual control panel’s 
instructions for details). Available addresses are from 
00 through 30. The keypad is shipped with a default 
address of 31 (non-addressable mode). To change the 
address, do the following: 

 

1. 

Enter keypad address mode: 

Power up the keypad. Within 60 seconds of power-
up, press and hold down the [1] and [3] keys together 
for 3 seconds. The current address will be displayed 
and the cursor will be under the “tens” d igit (

31

).  

Notes: 

If a keypad needs to be re-addressed to work with your 
control, there is no initial time limit to change the 
address. However, once a correct address is entered or 
successful communication is made with the control 
panel, the following notes apply. 

 

• 

If system has been powered up for more than 2 
minutes, you must power the keypad down, then 
power it up again in order to change the keypad’s 
address.  

• 

The keypad will not enter the address mode if the 

system is in the program mode. 

• 

If 10 seconds have passed with no key entry, the 
keypad automatically exits the address mode. 

• 

The current address may be viewed at any time by 
pressing and holding [1] and [3] keys together. 

2. 

Set the desired address:

 

Enter the desired address. For example, for address 
12, enter 1, then 2. Display shows (12). 

3. 

Exit the address mode:

 

Press the “star” key

 

(

)

 

to save the displayed address 

and exit the address mode. 

KEYPAD LABELS 

Function key labels:

 A set of adhesive-backed labels 

with some typical function symbols (e.g., fire, police, 
emergency, etc.) is provided. These labels come in four 
colors (red, blue, green, and white) and may be placed 
on the appropriate function keys (A, B, C, or D) for ease 
of identifying the individual key’s function (as 
determined by the control panel’s capability and 
programming). 

SPECIFICATIONS 

Physical:

 

5.250” H x 7.437” W x 1.312” D 

Display:

 

Alphanumeric, 32-character (2 lines x 
16 characters), LCD back-lit 

LEDs:

 

Armed (red), Ready (green), *Trouble 
(yellow) and *Supervisory (yellow) 

 

* See control panel’s instructions for 
specific applications regarding Trouble 
and Supervisory LEDs. 

Sounder:

 High-quality 

speaker 

Electrical:

 

 Voltage: +12VDC 

 

Current: 45mA standby; 

 

150mA in alarm (sounder, 
back light and LED on)

 

 