ADE Reson8 Series Installation Instructions Download Page 2

Wiring

Reson8

ADE Control
panel

Other control panel

STB-

STROBE -

- Strobe or -ST

TRIG-

B -

Bell -

HOLD OFF -

A -

Tamper supply -

HOLD OFF + D +

Bell +

RTN-

T -

Tamper return -

BATTERY -

Connect - from Reson8 battery

B

C from Reson8 battery

Timer

The Reson8 will operate under normal
alarm conditions as directed by the
control panel. However, if the Reson8
is triggered into Self Activating Bell
mode (SAB), due to power loss or
cable damage, then the sounder will
operate from the Ni-Cad battery for the
set time. The minimum time setting is
marked as "TEST" which will limit the
bell to 5 seconds of operation.

"

After testing, please ensure that the timer is

correctly set to the desired position. The 20 minutes
duration is typical for most installation.

Status Indicators

The two LED indicators are used to display the status of the
Reson8. The red LED illuminates to indicate the hold off supply is
present. The green LED illuminates to show the there is no
tamper, that is the tamper circuit is closed and healthy.

The LED status indicators will operate in one of
two modes as a means of deterrent.

ALT: Alternating between Red & Green LED's
or CON: Red & green LED's are constantly
illuminated.

Battery Enable

Reson8 is supplied with a 6 Volt internal Ni-cad
battery, as part of the Self Activating Bell (SAB)
circuit. When commissioning the system you will
need to enable the battery in order to provide
battery back up in the event of mains supply
failure.

&

Note on connecting the battery link the

sounder will output tamper alarm.

Final Test

When installation is complete the Red (Hold Off Supply) LED
indicator should be illuminated. The green indicator will illuminate
when the lid is securely fixed into position.

We recommend that the following tests are then carried out:

¨

Test the operation of the sounder and the timer in
self-actuating mode, by removing the hold off supply to the
Reson8.

¨

Test the operation of the front cover tamper.

¨

Test the operation of the sounder and strobe, by generating
an alarm condition at the intruder control panel.

Installation

Reson8

Novar Systems Limited reserves the right to revise this publication from time to time and make changes to the

content hereof without obligation to notify any person of such revisions of changes.

Hamilton Industrial Park, Waterside Road, Leicester LE5 1TN, UK

Website: www.ade.co.uk

Tel44 (0) 116 246 2000

Fax (UK): +44 (0)116 246 2566

Registered office: Novar House: 24 Queens Road, Weybridge, Surrey KT13 9UX

2

4188-831 issue 1_2/05_reson8

-

STROBE

J6

+

T

A

SCB

D

B

BELL

+

-

SET

+ve

1A

BELL/STROBE

F5

Panel

Board

-

BATTERY

+

-

RTN

-

HOLD

OFF

+

-

TRIG

-

STB

Board

Reson8

-

BATTERY

+

-

RTN

-

HOLD

OFF

+

-

TRIG

-

STB

Board

Reson8

Green

Black

Red

Blue

Y

e

llow

White

T

D

A

B

T

D

A

B

-

STROBE

J6

+

T

A

SCB

D

B

BELL

+

-

SET

+ve

1A

BELL/STROBE

F5

Panel

Board

-

BATTERY

+

-

RTN

-

HOLD

OFF

+

-

TRIG

-

STB

Board

Reson8

Green

Black

Red

Y

e

llow

White

T

D

A

B

J6

J5

J3

J4

Test

20 minutes

5 minutes

10 minutes

TIMER SETTINGS

A
L
T

C
O
N

LEDs

J2

LED3

(Red)

LED2

(Green)

On

Off

Battery

J1

Reviews: