ADE M501660 Operating Manual Download Page 9

M501660-210512-Rev003-UM-e 

 

 

Capacity parameters are not correct. 

Contact your local dealer / supplier 
for a new set-up. 

 

Calibration error. The incoming signal of 
loaded weight is too small, too big, 
unstable or un-linear. 

Contact your local dealer / supplier 
for a new set-up. 

Not turn on. 

Power cord is not properly connected. 
Power outlet not supplying electricity. 
Batterie is discharged. Other failure. 

Check power cord connections. 
Make sure power cord is plugged 
into the power outlet. Check power 
source. Replace batteries. 

Cannot zero the 

display or will 

not zero when 

turned on. 

Load on scale exceeds allowable limits. 

Load on scale is not stable. 

Load cell damage. 

Remove load from the scale. 

Wait for load to become stable. 

Service required. 

No Battery 

symbol or 

display of Lo.bAt  

Batteries are discharged. 

Charge batteries. 

 

Cleaning and Maintenance 

Cleaning 

Before cleaning disconnect the scale from the socket. For cleaning just use a damp cloth or common 
disinfection fluids. Do not use any aggressive cleaning fluids, abrasive or acid cleaners or  white spirits. 
During he process of cleaning take care that no water or cleaning fluids are penetrating the scale. 

Storage and Transport 

Please keep all original parts and pieces for an eventual sending back of the scale 

in order to avoid any possible damage during transport, which automatically leads to non warranty. 

Disconnect all cables before transport and avoid unnecessary damages. 

Warranty – Liability 

ADE will repair or replace this product within a period of 2 years from date of delivery applying to 
defects occurred due to poor material or workmanship (presentation of invoice is necessary). All 
moveable parts – batteries, cables, mains units, rechargeable batteries etc. – are excluded. Warranty 
does not include natural wear, damages caused by incorrect or negligent handling, overuse or 
unsuitable or improper storage. The cost of transport will be borne by the customer should the 
equipment be located anywhere other then the customer’s premises. In the event of transport 
damage, claims under warranty can be accepted subject to using the complete original packaging and 
the equipment secured the way it was packed and secured originally. All the packaging should 
therefore be retained.  

Any warranty claim will be rejected if the equipment is opened by persons not authorized expressively 
by ADE to do so. 

Customers abroad are kindly requested to contact their local dealer for any warranty claim, customer 
service and spare parts. 

 

 

Summary of Contents for M501660

Page 1: ...Operating Manual International Range Electronic Wheelchairs M501660 M501660 210512 Rev003 UM e...

Page 2: ...escription 4 Key Description 5 Weighing 5 Correct weighing 5 How to change the unit 5 Tare function 6 Weighing with preset tare values 6 HOLD function 6 BMI Body Mass Index 6 Evaluation of the Body Ma...

Page 3: ...ly follow the safety instructions in this operating manual the country specific installation standards as well as the applicable safety conditions and accident prevention regulations in all aspects Op...

Page 4: ...IMH rechargeable batteries Use the AC adapter to load the rechargeable batteries The imprinted voltage value at the mains adapter must match the local mains voltage When the battery is being charged f...

Page 5: ...dstill status indicator 14 The scale is at a standstill meaning the weight is stable and no movement is on the platform This is a mandatory precondition for functions such as resetting printing and ta...

Page 6: ...g Correct weighing Press the start key ON OFF to enter the normal operating mode of the scale with no load on the platform An automatic function test will be performed as well as the zero setting of t...

Page 7: ...appear at the display and ignored by the scale HOLD function The Hold function is being used if you like to hold the results at the display after the weight load has been removed from the scale Use t...

Page 8: ...t a record The scales must be at standstill The standstill status symbol must appear at the screen Press the ENTER key to send the data to the serial interface Note Printing is not possible if the net...

Page 9: ...trating the scale Storage and Transport Please keep all original parts and pieces for an eventual sending back of the scale in order to avoid any possible damage during transport which automatically l...

Page 10: ...00mA Central negative 4xAA NIMH rechargeable batteries pack Display 6 digit 7 segment 1 25mm LCD with 16 annunciators and blue backlight Working temperature 10 C to 40 C Storage temperature 20 C to 70...

Page 11: ...ity by the manufacturer These scales have been manufactured in accordance with the harmonised European standards They conform to the regulations of the EC directives listed below EMC Directive 2014 30...

Page 12: ...11 M501660 210512 Rev003 UM e authorised dealer...

Reviews: