Cleaning and Maintenance 

 

Cleaning 

 
 
Before cleaning make sure the scale has been disconnected from the socket. 
For cleaning just use a damp cloth or common disinfection fluids. 
Do not use any aggressive cleaning fluids. 
Make sure no water or cleaning fluids is penetrating the scale. 
 

Your ADE scale is equipped with a mains adapter and rechargeable batteries. 
 
If the display shows the symbol `Low´ the power pack needs to be recharged by using the adapter. 
 

Safety Check 

 
 
Do NOT use the scale 

  If the mains adapter shows visible damages. 

  if the mains adapter is not working properly any more 

  After long storage in humid places 

Please contact your dealer or service partner in those cases. 
 

Storage and Transport 

 
 
Please keep all original parts and pieces for an eventual sending back of the scale 
in order to avoid any possible damage during transport which automatically leads to non warranty. 
 
Disconnect all cables before transport and avoid unnecessary damages. 
 

Warranty – Liability 

 
ADE will repair or replace this product within a period of 2 years from date of delivery applying to 
defects occurred due to poor material or workmanship (presentation of invoice is necessary). All 
moveable parts – batteries, cables, mains units, rechargeable batteries etc. – are excluded. Warranty 
does not include natural wear, damages caused by incorrect or negligent handling, overuse or 
unsuitable or improper storage. The cost of transport will be borne by the customer should the 
equipment be located anywhere other then the customer’s premises. In the event of transport 
damage, claims under warranty can be accepted subject to using the complete original packaging and 
the equipment secured the way it was packed and secured originally. All the packaging should 
therefore be retained.  
 
Any warranty claim will be rejected if the equipment is opened by persons not authorized expressively 
by ADE to do so. 
 
Customers abroad are kindly requested to contact their local dealer for any warranty claim, customer 
service and spare parts. 

Summary of Contents for M30610

Page 1: ...Operating Manual Electronic Floor Scale M30610 ADE GmbH Co Hammer Steindamm 27 29 D 22089 Hamburg Germany 49 40 432776 0 Fax 49 40 432776 10 E mail info ade hamburg de...

Page 2: ...ighing 3 Weighing 4 To take the weight 4 Change unit function 4 Set zero 4 Tare function 4 Definition and use of BMI Body Mass Index 5 Evaluation of the Body Mass Index 5 HOLD function 5 Cleaning and...

Page 3: ...ing Key to switch between weighing mode kg or lb and key in height for BMI function HOLD key and BMI Body Mass Index selecting key Display symbols Weighing result is displayed most accurately Scale is...

Page 4: ...mains adapter Complete first charging needs 24 hrs Place the scale in its working area Make sure to place the scale on an even ground The scale is now ready for use Caution Please operate the scale o...

Page 5: ...heck weighing mode after switching to get proper result Set zero You may set any displayed weighing result back to zero 0 0 by pressing the ZERO key The advantage is to weigh shoes or dress separately...

Page 6: ...s again HOLD BMI key Evaluation of the Body Mass Index BMI below 18 The patient is not showing enough weight Control nutrition to put on weight BMI between 18 and 20 The patient is slightly under weig...

Page 7: ...connect all cables before transport and avoid unnecessary damages Warranty Liability ADE will repair or replace this product within a period of 2 years from date of delivery applying to defects occurr...

Page 8: ...alid EC Directive 89 336 EEC for electromagnetic compatibility Products carrying this sign correspond to the standards of Directive 73 23 EEC for low voltage Technical data Max Capacity 200 kg 440 lbs...

Reviews: