This  symbol  means:  "Consult  operating  instructions".  To  achieve  accurate  results,  read  the 
instructions for use carefully before use and follow all instructions provided therein. Keep the 
instructions for use for future reference. 

 

Your ADE electronic scale is a quality, sturdy and durable product manufactured under the high standards and 
regulations for calibrated class III scales in accordance with national regulation in Germany. The scale 

is de-

signed and manufactured for the daily practice in hospitals, doctors’ surgeries and in-patient nursing facilities.

 

The scale is especially being designed for the use of adipose patients. 

ADE instruction manuals have been prepared to provide the user with all the necessary knowledge about the 
safe use of ADE scales and their related accessory equipment.  

For further questions about how to use the products or about this or other service manuals, feel free to contact 
your local ADE representative or visit our web page at www.ade-hamburg.de  

Assembly 

The indicator/ display of your ADE scale is able to be mounted on walls, on sockets, handrails or on stand-on 
devices for the table depending on the model you have selected.  
Please insure that your scale is being placed vibration free of any vibration and at a dry place.  
Please take the indicator and the cable extension out of the packaging and follow the instruction for assembly. 

Attachment of the indicator 

The ADE scales are delivered in a largely assembled state. Only model M301020 requires the indicator to be 
connected to the weighing platform. Connect the indicator to the scale platform using the connector provided. 

 
Alignment of the scale

 

 
Place the scale on a plain, dry and level surface. 
Adjust the scales so that all feet are in contact with the surface. 
The air bubble in the spirit level should be right in the centre of the circle 
If the scale has been transported or stored, it must be re-adjusted as described above. 

Power supply 

Power is supplied either by the rechargeable battery in the display unit or by the mains power via the supplied 
power unit. The imprinted voltage value at the mains adapter must match the local mains voltage. 

After checking same connect the mains cable to the indicator and to a socket.  

 

Note:  The  wall  socket  must  be  located  near  to  the  unit  and  be  easily  accessible.  Please  use  only  the  mains 
adapter supplied by ADE. The mains adapter is charging the battery pack at the same time. 

 

When the battery is being charged for the first time a sufficient charging period of approx. 24 hours is neces-
sary to achieve a full battery load. 

In  case  the  scale  is  being  used  with  batteries  only  and  the  display  indicates  – 

Lo

,  the  battery  should  be  re-

charged with the ADE mains adapter. After the first charging period the battery need 12-16 hours. The battery 
should be charged while the scale is switched off. Upon completion of the charging period switch the scale on 
again to check the battery status. In case  

Lo

- still appears on the display inform your service partner. 

Summary of Contents for M301020 Series

Page 1: ...M301020 01 210322 Rev005 UM e Operating Manual Class III approved Scales Electronic Platform and Handrail Scales Series M301020...

Page 2: ...al devices 6 Housing and connections 7 Modes 7 Settings 7 Setting date and time 8 Operation 8 Weighing 8 Resetting the scales back to zero 8 Tare function 8 Hold function 9 Determining the Body Mass I...

Page 3: ...y Attachment of the indicator The ADE scales are delivered in a largely assembled state Only model M301020 requires the indicator to be connected to the weighing platform Connect the indicator to the...

Page 4: ...d require a recharging period If the bat tery performance drops considerably then it is time to replace the battery New batteries are supplied only partially charged Some batteries only achieve their...

Page 5: ...button Short push on the button to recover the stored tare value Long push on the button to enter and save the tare value 11 BMI Button Enter to proceed with BMI mode and to enter as next step the he...

Page 6: ...s not pose any potential trip hazard Only use approved accessories and peripheral equipment Only operate the unit under permitted ambient conditions Remove the mains plug before cleaning the unit Do n...

Page 7: ...s for print commands are being set in this mode To start setting mode hold the GROSS NET key pressed until TIME appears on the display Configuration mode set up mode The values for different parameter...

Page 8: ...the scale are being compensated The zero key restarts the scale The status indicator 6 appears when the scale is being resetted Tare function The TARE key 9 is used when the patient is being weighed...

Page 9: ...scale To do this the scales must be at standstill e g the standstill status indicator 14 is on depending on the setting it is not always necessary for the scales to be at standstill The Hold status i...

Page 10: ...city of the scales Overflow indicator negative Negative weight indicated weight too low to be displayed 99999 Overflow indicator positive Positive weight indicated weight too high to be displayed 9999...

Page 11: ...tc are excluded This warranty does not cover any normal external appearance of use and wear or any damage occurring as a result of an accident or misuse Any warranty or damage compensation claims pres...

Page 12: ...ort Full duplex RS 232 38400 19200 9600 4800 2400 1200 bps Printer Port Output only RS 232 or active 20 mA current loop 9600 4800 2400 1200 bps Both Ports 7 or 8 data bits even odd or no parity Operat...

Page 13: ...ufacturer This product has been manufactured in accordance with the harmonised European standards They con form to the regulations of the EC directives listed below NAWI Directive 2014 31 EC Medical D...

Page 14: ...14 M301020 01 210322 Rev005 UM e...

Page 15: ...M301020 01 210322 Rev005 UM e 15...

Page 16: ...16 M301020 01 210322 Rev005 UM e Dealer...

Reviews: