ADE LWX200 Series Operating Manual Download Page 19

LWX200-210408-Rev003-UM-en 

19 

 

Disposal 

 

Waste electrical equipment do not belong in household waste. Devices 
with this marking may not be disposed of as residual waste, but must 
be recycled. 

 

Remove (if possible) all batteries and rechargeable batteries from the 
devices and send them to the battery disposal. 

 

Make sure that only depleted batteries or batteries with insulated poles 
are disposed of so that there is no short circuit! 

Warranty 

ADE will repair or replace this product if evidence is provided that it has failed within 1 year from 
the date of sale (proof of purchase is required) due to lack of workmanship or defective material. 
All moving parts, such as batteries, cables, etc. are excluded. 

The use of accessories other than those approved by ADE, especially batteries, will void the 
warranty. 

This warranty does not cover external normal wear and tear or damage caused by accident or 
misuse. The warranty will not apply for devices that have been opened by unauthorised persons. 
The statutory rights of the customer are not affected by this agreement in any way. 

The dealer from whom the scale was purchased is responsible for complaints, customer service 
and spare parts. 

Recalibration  

According to the national regulations of the legislature, only authorised companies or 
authorised personnel can perform recalibration. On the CE mark, you can find the year of 
initial calibration next to the notified body (0122). 

Recalibration must be carried out when: 

-  one or more security marks were damaged, 

-  after the scale has been repaired, 

-  after expiry of the period, set by the national regulations for recalibration. 

 

 

Summary of Contents for LWX200 Series

Page 1: ...OPERATING MANUAL Electronic price computing retail scales Retail scale LWX200 series LWX200 210408 Rev003 UM en...

Page 2: ...status indicator 9 8 Using the scale 10 Preliminary Note 10 Switching the scale on and off 10 Reset 10 Price entry 10 Taring 11 Saving and retrieving article prices and or tare values 11 Saving direc...

Page 3: ...for everyone When reselling the scale the operating manual must also be supplied Target group This operating manual is intended for personnel who are responsible for setting up operating care and main...

Page 4: ...DE scale is a quality product and was manufactured for use as a non automatic scale The scale is used to determine the weight and price of goods to be weighed and is intended for use in supermarkets g...

Page 5: ...f the scale and the other end to the local power supply In this case before connecting the supplied mains adapter to the scale make sure that the voltage on the nameplate matches the local power suppl...

Page 6: ...attention to the correct positioning of the column parts upper and lower end 4 Put the display on the column and screw both with the enclosed countersunk screws 5 Insert the column into the column mo...

Page 7: ...he object e g a container is tared by pressing it once and the scale switches from gross to net mode Taring is indicated by the NET symbol on the display FIX To activate or deactivate price and automa...

Page 8: ...OFF On and off key The scale is switched on by pressing this key The scale is switched off again by pressing this key again Menu guidance keys Symbol Description Function TARE key For calling and conf...

Page 9: ...e by piece amount Weight determination is not possible kg Display of the basic price unit per kilogramme 100g Display of the basic price unit per 100 grammes FIX Display for enabled fixed price functi...

Page 10: ...off the scale Automatic deactivation of the scale The scale is equipped with a power saving function As a result the scale switches off after a period of time that can be set by the user see section 9...

Page 11: ...e container from the scale together with the goods to be weighed As a net weight the scale shows the tared weight of the container as a negative value After unloading the platform and pressing the key...

Page 12: ...Use the and keys to choose between price calculation based on the Unit price Amount Basic price per kg Weight kg and Basic price per 100 g Weight 100 g Confirm your entry by pressing the key The disp...

Page 13: ...rieval for determination based on quantity To retrieve a direct PLU select one of the keys The display shows the data stored on the PLU Now enter the number of pieces to be calculated In addition to t...

Page 14: ...ion based on the Unit price Amount Basic price per kg Weight kg and Basic price per 100 g Weight 100 g Confirm your entry by pressing the key The display now shows the entry of the unit or basic price...

Page 15: ...retrieval for determination based on quantity To retrieve an indirect PLU press the key Use the keys to select the memory space 00 99 from which the data must be retrieved The display shows the data s...

Page 16: ...settings Backlight setting The scale has three different backlight setting options OFF The backlight is switched off permanently MANUAL The backlight can be switched on and off by pressing the key AUT...

Page 17: ...as F0 CAL and F14 GrA are blocked on calibrated scales A change leads to the loss of the calibration and is only reserved for qualified personnel authorised by the manufacturer Indicator Description F...

Page 18: ...s not possible Zeroing is not possible if the displayed weight exceeds 2 of the capacity of the scale In this case switch the scale off and on again Error messages Failure Cause Measure ERR 4 Current...

Page 19: ...e of accessories other than those approved by ADE especially batteries will void the warranty This warranty does not cover external normal wear and tear or damage caused by accident or misuse The warr...

Page 20: ...for weight basic price and total price 9 5 mm high tare weight characters adjustable backlight Casing Stable plastic housing Keypad Easy care membrane keypad with acoustic key function control Functi...

Page 21: ...ctive 2014 31 EU EMC Directive 2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EU in their respectively applicable versions This declaration will lose its validity if any modificati...

Page 22: ...22 LWX200 210408 Rev003 UM en...

Page 23: ...LWX200 210408 Rev003 UM en 23...

Page 24: ...24 LWX200 210408 Rev003 UM en Distributor...

Reviews: