ADE LW100 Series Operating Manual Download Page 4

LW100-210408-Rev002-UM-en 

 

-  Place  the  scale  as  far  as  possible  from  other  devices  or  sources  that  generate 

electromagnetic field or other interferences (e.g. strong motors and portable and mobile HF 
communication devices) as these can falsify the measurement results. 

-  Use only approved accessories and peripherals.  

-  Before cleaning the device, pull the mains adapter/plug out of the socket. 

-  Never clean the scale with abrasive or aggressive cleaning agents. 

-  Do not immerse the device in water or other liquids. 

-  If  you  have  problems  with  this  device,  e.g.  when  setting  up,  maintaining  or  using,  please 

contact the authorised customer service. Do not open or repair the device yourself. 

-  Please notify the authorised customer service if unexpected operations or events occur. 

-  If the weighing system is not used for a longer period of time, it should be cleaned and stored 

in a protective film. The addition of a drying agent is desirable. 

 

DO NOT use the scale: 

-  If the mains adapter is damaged; 

-  If the mains adapter is not working; 

-  If the battery compartment has an unnatural bulge; 

-  After long storage in a humid environment. 

In such cases, please contact authorised customer support. 

4.  Intended use 

Your ADE scale is a quality product and was manufactured for use as a non-automatic scale. 
The scale is used to determine the weight and price of goods to be weighed and is intended for 
use in supermarkets, grocery stores, retail stores, markets and similar areas of application. 

To  determine  the  weight  and  price,  carefully  place  the  item  to  be  weighed  as  centrally  as 
possible on the scale. The scale may be loaded with the maximum load (Max) specified on the 
device and on the nameplate. After a stable measurement result has been determined, it can 
be read off. 

The  scale  must  not  be  used  for  dynamic  weighing.  If  small  quantities  are  slowly  added  or 
removed (e.g. filling liquids), this can lead to incorrect measurement results. 

The device may only be used as intended. All applications of the device that are not mentioned 
in  the  chapter  “Intended  use”,  as  well  as  non-observance  of  the  safety  instructions,  are 
considered improper use. It is the user of the device, but not the manufacturer, who assumes 
liability for any resulting damage to property or personal injury resulting from misuse. 

The use of accessories other than the original accessories supplied by the manufacturer may 
void this warranty. 

 

The weighing system may only be used for legal-for-trade weighing if it is 
verified. The verification is invalid without a seal. 

This device may not be modified without the manufacturer's permission. 

 

 

 

Summary of Contents for LW100 Series

Page 1: ...OPERATING MANUAL Electronic price computing retail scales Calibrated retail scale LW100 series LW100 210408 Rev002 UM en LW100 series...

Page 2: ...controls 7 Button terms and functions 7 Menu guidance keys 8 Display 8 Battery status indicator 9 8 Using the scale 9 Preliminary Note 9 Switching the scale on and off 9 Zero Setting 10 Price computi...

Page 3: ...for everyone When reselling the scale the operating manual must also be supplied Target group This operating manual is intended for personnel who are responsible for setting up operating care and main...

Page 4: ...DE scale is a quality product and was manufactured for use as a non automatic scale The scale is used to determine the weight and price of goods to be weighed and is intended for use in supermarkets g...

Page 5: ...sent on your model The transportation locking device is identified by the labels below Not removing the transportation lock can lead to incorrect weighing results 3 Place the scale on a level stable s...

Page 6: ...is not properly ready for operation Switch off the scale and turn it on again 7 For precise measurement results the goods to be weighed must be placed in the centre of the weighing platform The goods...

Page 7: ...asic price ZERO Zeroing key If this key is pressed the scale is returned to the zero position TARE Tare key The object e g a container is tared by pressing it once and the scale switches from gross to...

Page 8: ...the net weight of the item to be weighed 2 Display of the basic price per kg 3 Display of the total price determined from net weight and basic price Display symbols Symbol Meaning Display for stable w...

Page 9: ...sing the scale Preliminary Note Do not load the scale with weights that exceed the maximum capacity As soon as you perceive the signal for an overload this is shown by oL on the display immediately re...

Page 10: ...weight of the product to be weighed is displayed Carry out as many weighing operations as required As long as the tared container remains on the weighing platform only the net weighing results and th...

Page 11: ...lace the new container to be tared on the weighing platform and press the key again To end the fixed tare function press the key Combined fixed price and tare function To simultaneously store a fixed...

Page 12: ...seconds The displays Weight and Price show bLSET MODE The display Total shows the selected option You can change the setting by pressing the direct PLU keys or Confirm your setting by pressing the key...

Page 13: ...fields static charging Choose a different location If possible switch off the interfering device Zeroing is not possible Zeroing is not possible if the displayed weight exceeds 2 of the capacity of th...

Page 14: ...ack of workmanship or defective material All moving parts such as batteries cables etc are excluded The use of accessories other than those approved by ADE especially batteries will void the warranty...

Page 15: ...price computing Fix function fixed price fixed tare Automatic zero setting Overload display Battery level indicator at low supply voltage Price entry display Min price entry Preiseingabe anzeige Max p...

Page 16: ...ctive 2014 31 EU EMC Directive 2014 30 EU Low voltage directive 2014 35 EU RoHS Directive 2011 65 EU in their respectively applicable versions This declaration will lose its validity if any modificati...

Page 17: ...LW100 210408 Rev002 UM en 17...

Page 18: ...18 LW100 210408 Rev002 UM en...

Page 19: ...LW100 210408 Rev002 UM en 19...

Page 20: ...20 LW100 210408 Rev002 UM en Distributor...

Reviews: