ADE HWZ Series Operating Manual Download Page 20

20 

 

HWZ-190214-Rev006-UM-en 

 

Distributor: 

 

 

Summary of Contents for HWZ Series

Page 1: ...ounting scale of HWZ series HWZ 190214 Rev006 UM en ADE Germany GmbH Co KG Hammer Steindamm 27 29 22089 Hamburg GERMANY 49 0 40 432776 0 49 0 40 432776 10 info ade hamburg de IMPORTANT READ CAREFULLY...

Page 2: ...unit weight 7 8 3 2 Weighing a sample to determine the unit weight 8 8 3 3 Entering a known unit weight 8 8 4 Counting more units 8 8 4 1 Automatic update of the unit weight 9 8 4 2 Presetting the max...

Page 3: ...s However improper use may cause personal injury and dam age to property Read the operating manual carefully before putting the device into operation This will prevent damage to the device Keep the op...

Page 4: ...through a test programme and acknowledges the end of the routine with an acoustic signal If the weighing platform is loaded when switching on the scale the scale will not be properly calibrated and re...

Page 5: ...al sounds Print key Used to print the totaliser when connected to a printer or PC Requirement Optional RS232 data interface is installed Count key Used to enter the number of units Sample weight key U...

Page 6: ...r to warn the user of a potential problem If a preset number of units has been saved a small arrow appears above the symbol 7 3 Count window COUNT This window shows the number of units on the scale or...

Page 7: ...econd method This method allows you to enter a value for the tare weight using the keypad This is useful when you are using the same containers or when the container is already full while the net weig...

Page 8: ...f the weight is below zero the Count window shows a negative number of units 8 3 3 Entering a known unit weight If the unit weight is already known this value can be entered using the keypad Enter the...

Page 9: ...Use the 10 key keypad to enter the minimum weight at which an acoustic signal should sound and confirm with the key You will now return to weighing mode To delete the preset values from the memory an...

Page 10: ...e set to be permanently on it can also only be switched on when a weight is on the scale or it can be turned off To adjust the backlight press and hold down the key for 6 seconds The Weight window sho...

Page 11: ...the key to navigate through the options The value can be set to 0 5d 1d 2d or 4d Normally it is set to 1d but it can be increased in order to zero the scale if there is a small amount of material spil...

Page 12: ...plug the power adapter into the scale and switch on the mains voltage The scale does not need to be switched on The rechargeable battery must be charged for 12 hours to its full capacity There is an...

Page 13: ...hing range when the scale is switched on or when the key is pressed The weighing platform has already been loaded when the scale has been switched on Weighing platform overload when the scale is set t...

Page 14: ...belong in the domestic waste Please dispose of defective or old products and batteries with the legal and au thorised channels Please make sure that only discharged batteries or batteries with insulat...

Page 15: ...ically 2 seconds Operating tempera ture 0 C 40 C Protection type IP34 Power supply 6 DC 4 AH cold device power cord via 230 V power connection Calibration With external weight Indicator Three 6 digit...

Page 16: ...in accordance with the harmonised European standards It conforms to the provisions of the EC directives cited below EMC Directive 2014 30 EU regarding electromagnetic compatibility Low voltage directi...

Page 17: ...HWZ 190214 Rev006 UM en 17...

Page 18: ...18 HWZ 190214 Rev006 UM en...

Page 19: ...HWZ 190214 Rev006 UM en 19...

Page 20: ...20 HWZ 190214 Rev006 UM en Distributor...

Reviews: