ADE BA1401 Operating Instructions Manual Download Page 5

 

5

C

ONDITIONS OF USE

 

The measurements should take place without clothes, if possible, and always barefoot. 

Since the body is subject to natural fluctuations (e.g. dehydration through sports or sauna, intake of food and 

fluids), constant conditions should be ensured when measuring, so as to receive comparable values. 

Care should be taken that the measurements are always carried out at the same time of day. Directly after get-

ting up in the morning, the water has not yet spread through the body. This means that the resistance is still rela-
tively high, due to the bad conductivity in the body. With increasing movements throughout the day, the water 
spreads through the body, increasing conductivity, which causes the resistance, and thus the fat level too, to be 
shown as lower. To determine the actual changes of body composition, it is therefore important to measure al-
ways at same time. An easy way of doing this is by always measuring a quarter of an hour after getting up in the 
morning, either before or after using the toilet. 

Despite the minimum current, persons with pacemakers or other implants, which emit frequencies, must 

not use the body analyser scales! 

Other implants, e.g. a titanium plate in the knee, pose no danger. Metals, however, conduct electricity extremely 

well, which has the effect that body fat values are “beautified”, meaning that the actual fat level is higher than 
shown by the scales. Tendencies, on the other hand, can be determined just as well. In women, menstrual factors 
have an effect on the measurement results, since hormonal fluctuations influence the body's water balance. If the 
body contains all lot of water, the fat values are lower, if less water is contained, the values are a little higher. 
When a woman is pregnant, there is no danger for the unborn child. But due to larger water deposits during 
pregnancy, the values are distorted making the measurement senseless. 

 

 

Summary of Contents for BA1401

Page 1: ...al s bject to technic erating Manua Body with Blueto in linked ap Opera cal changes as al_BA1401_EN y An tooth and d app ating In s a result of pr N_131206_REV alyse data manag structio roduct improve...

Page 2: ...TIONS OF USE 5 FIRST USE 6 SCALE COMPONENTS 6 LCD DISPLAY 6 HOW TO INSTALL THE BATTERIES 6 INSTALLING THE ADEVITAL APP AND CONNECTING 7 MONITORING FOR YOUR BODY ANALYSER SCALES 7 SELECTING THE UNIT OF...

Page 3: ...ntion The p dvice from a es have Blue ntended Nea dy analyser sc ncy commun ments and mus trical devices 3 RUCTIONS ensure you u nd symbols o ng instruction ed device ent medical ments of Eur trical p...

Page 4: ...o operate and wever please t not use thes s is only avail the iPhone4S required NT he scales un es vice if you ha c medical de g artificial he f slipping if th ects fall onto t e any mobile n a flat...

Page 5: ...tant to measure al ways at same time An easy way of doing this is by always measuring a quarter of an hour after getting up in the morning either before or after using the toilet Despite the minimum c...

Page 6: ...g one pprox 6 35 k ound pprox 0 45 k over on the ba A into the bat LCD display over and wait 6 iduals includ cessary expe e for their sa n do not play kg kg ack of the sc ttery compar t until 0 0 kg d...

Page 7: ...ll data and v LYSER SCALE alues weight ntervals email functio d app and co tures of the a ales is only a Air iPad min h 4 0 is requ Act Make that y Pre to s l is displaye e all four batte d of as haza...

Page 8: ...t running CD display w d on the LCD MENT supplied bat our country s ay SONAL DATA ur details in al evices hold down t flashing zero s found your uct that has b ent users of th d profiles s the scales...

Page 9: ...ilis et are the mo ht and a lack 9 ackaging a deep pile c ntact with the lyser scales t nks to the pat cales stand s only possible ered in the ad n full contact nected via B 401 automati again the us...

Page 10: ...analyser s re should be Bluetooth dev cularly devic ser scales to 10 of WATER Thi water water water and th oximately 22 mass The va dy water app d is extracell together alw t and the wa BA1401 and sfe...

Page 11: ...soon as 11 Do not use Please alw batteries as Please che Bluetooth The app The dista Bluetooth ription ng anding on a OR on a ro oor blood circ or your feet t been installe as those caus s the interf...

Page 12: ...re for your de ff the device water and rung or immerse it other chemic he event of p ion y material or e date At the antee claim p 22089 Ham ured accordin Directives 04 108 EC 99 5 EC onger be valid 1...

Page 13: ...cal council recycling centre or the shop where you bought the product Best regards Waagen Schmitt GmbH Co TECHNICAL DATA Product name BA1401 adeVital analysis body analyser scales with app BA1401 Dime...

Page 14: ...59 17 17 1 24 24 1 27 27 23 23 1 31 31 1 34 34 60 18 18 1 25 25 1 28 28 24 24 1 32 32 1 35 35 TABLE OF PERCENTAGE OF BODY FAT UNIT Gender Range of the percentage of body fat Optimum range of the perce...

Page 15: ...se return this se Operating ard 3 years hase __________ ection and proof of pu g Manual_BA1401_E on the body _______ urchase to your retaile EN_131206_REV001 analyser scale Reason f er 15 es except we...

Page 16: ...ge Today s h manage an e with Blue health mon nd analyse etooth func nitoring tec e health da ctionality a chnology 16 ata simply and the inte and clearly telligent ad ly with the deVital app e new ad...

Reviews: