The Addvent AVX100WLED 

has

 

the following features:

• Single speed extraction

• 12 V (ac) fan operation

• 12 V (dc) light operation

•  When switched off, the fan continues to run for a 

pre-set delay from 30 seconds to 30 minutes.

• A transformer provides a Safety Extra Low

Voltage (SELV) power supply.

• THE APPLIANCE IS DOUBLE INSULATED

AND DOES NOT REQUIRE AN EARTH
CONNECTION.

The contents of this kit includes:

Whisper Silent Showerlight and Fan

• 1x Safety Extra Low Voltage (SELV)

Transformer

• 1x 3m flexible duct

• 1x External Wall Grill

• 2x Tie wraps

• 7x Screws and wall plugs

Where to locate the unit

• Locate in the ceiling above the

shower area or cubicle.

• At least 110mm from the edges of

the mounting surface to the centre

of the hole.

• Not where ambient temperatures are likely to

exceed 50°C.

•  If installing in a room containing a fuel burning

device which has a non-balanced flue, it is the

installer’s responsibility to ensure that there is

enough replacement air to prevent fumes being

drawn down the flue when the fan is operating

up to maximum extract. Refer to Building

Regulations for specific requirements.

• Exhaust air must not be discharged into a flue

used for exhausting of fumes from appliances

supplied with energy other than electric.

Requirements of all authorities concerned

must be observed for exhaust air discharge

and intake flow rates.

• Not suitable for use in possible chemical

corrosive atmospheres.

What the installer will need

• 3mm electrician’s screwdriver and

No.1 or 2 Pozi-drive screwdriver.

Before you start, you will also need

• A 100mm diameter prepared hole for the unit.

• A 100mm diameter prepared hole for the

external vent. Ideally positioned to allow

condensation to run away from the first bend

in the duct toward the external vent. Refer to

Figure 5.

• A planned route for the duct, please consider

the following:

- The duct is 3m in length.

- The fan will perform best if ducting is kept

as straight and as short as possible. Avoid

sharp corners.

-  From the back of unit the duct should 

protrude straight out for at least 60mm before 

the first bend. This is to ensure that the 

backdraft flaps are free to open and close.

- Laying the duct so that after the first bend

the condensation runs out towards the

external vent. Refer to Figure 5.

• Some suitable insulation for the duct, if the

 

duct passes through a cold or unheated

 

space. Alternatively you can use an insulated

 

duct

.

• A means for disconnection of all poles

(Isolating switch). This must be incorporated

 

into the fixed wiring in accordance with the

 

wiring regulations. If metal switch boxes are

 

used, earthing regulations must be followed.

• A suitable operating switch.

• Two lengths of suitably rated 2 core cable for 

wiring from transformer to the unit.

• Suitably rated 3 core cable for wiring from the 

mains supply to the transformer, via the isolating 

switch and operating switch, as necessary. 

Summary of Contents for AVX100WLED

Page 1: ...INSTALLATION AND MAINTENANCE Addvent AVX100WLED Whisper Silent Shower Light Fan...

Page 2: ......

Page 3: ...duct with a means for disconnection in all poles in the fixed wiring Do ensure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleanin...

Page 4: ...not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric Requirements of all authorities concerned must be observed for exhaust air discharge...

Page 5: ...FIGURE 1 Unit Dimensions mm FIGURE 2 SELV Transformer Dimensions mm...

Page 6: ...FIGURE 3 Opening the unit FIGURE 4 Fixing positions mm MOTOR LAMP...

Page 7: ...y condensation build up will run towards external vent BAD Any condensation build up will run back into the room BAD Any condensation will be trapped causing collected water to stagnate constrict or e...

Page 8: ...R OUTPUT MOTOR LAMP LAMP OUTPUT TRANSFORMER TERMINALS OPERATING SWITCH FUSE ISOLATING SWITCH FOR ALL POLES For fixed wiring circuits the protective fuse for the appliance must not exceed 5A If the con...

Page 9: ...that the cover latch release slot is easily accessible 3 Mark the centres of the screw holes and cable entry Refer to Figure 4 4 Remove back plate and drill holes to the appropriate sizes 5 Fit wall p...

Page 10: ...supply Refer to Figure 6 The maximum rating for the fixed wiring circuit is 5A 2 Switch on mains supply Using Whisper Silent Shower Light Fan Operate the unit using an on off switch not supplied When...

Page 11: ...HER LIQUIDS BEFORE CLEANING FULLY ISOLATE ELECTRICAL SUPPLY TO THE UNIT The unit should be periodically wiped clean in position with a damp cloth and mild detergent No other maintenance is required Di...

Page 12: ......

Page 13: ...Bristol BS11 8HT www addvent co uk 08 100025 0 ISSUE 1 0418 Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your local authori...

Reviews: