Installation Instructions for the

AVCIMF

Mixed Flow Extractor Fans

Switch off mains supply before making any electrical 

connections. Installation must be supervised by a qualified 

electrician. This appliance can be used by children aged from 

8 years and above and persons with reduced physical, sensory 

and mental capabilities or lack of experience and knowledge if 

they have been given supervision or instruction concerning the 

use of the appliance in a safe way and understand the hazards 

involved. Children shall not play with the appliance. Cleaning 

and user maintenance shall not be made by children without 

supervision.
Precautions must be taken to avoid the back-flow of gases 

into the room from the open flue of gas or other open-fire 

appliances when mounted in outside windows or walls.
Fan must be disconnected from electrical power before any 

maintenance is carried out.

Wiring

1. Switch off mains supply before making electrical 

connections. If in any doubt contact a qualified 
electrician.

2. These units are for fixed wiring only. A flexible 

cord must not be used. All wiring must be fixed 
securely and the cable to the fan should be a 
minimum of 1mm

2

 in section. All wiring must 

comply with current I.E.E. Regulations or local 
regulations if outside the UK.

3. A double pole fused spur having contact separation 

of at least 3mm in all pole must be used and fitted 
with a 3A fuse.

4. This fan is double insulated and does not require 

an earth connection.

5. The fan should not be accessible to a person using 

either the shower or the bath. 

Location

1.  When installing this fan’s ducting through an 

external wall, an external wall grille must be fitted 
at all times.

2.  This fan should be fitted to ducting with a 

minimum duct length of at least 500 millimetres 
both sides of the fan.

3.  When using flexible ducting, ensure it is pulled 

taut. All ducting  should be angled towards the 
external grille.

4.  If the fan and duct extract grille is installed in 

a room containing a fuel burning appliance, the 
installer must ensure that the air replacement is 
adequate for both the fan and the fuel burning 
appliance.