6.2. Measure Speed

Estimates the read and write speed of the target media. After selecting this 

function, the port number in use will appear on the LCD, beginning with Port 

2 (the first target). Press the arrow buttons to switch between targets. Once a 

target is detected, the test will continue to run without accepting any more 

input until it is complete, then provide a short report on the read and write 

speed for the media found.

NOTE: 

NEVER remove a device while the LED is blinking.

6.3. Media Check

Performs a full examination of all space on target media using the following 

sub-options:

6.3.1. H3 Safe

Performs a read-only examination of media, without harming any data.

6.3.2. H5 R/W

Performs a destructive read-write examination of media.

6.3.3. Setup Range

This option determines how much of the media is examined by the Media 

Check, expressed as a percentage. This percentage is shown in the Media 

Check menu for the Safe and R/W options. Default setting is 100%.

6.3.4. Set Error Limit

This option determines how much of the tested media may show an error 

before a media is counted as a FAIL. Expressed as a percentage of the 

tested area. The Default setting is 0.

Media Check uses Asynchronous Mode, meaning devices may be removed 

once tested and new media may be inserted after the process begins.

NOTE: 

NEVER remove a device while the LED is blinking.

6.4. Quick Erase

Erases all content on all target media, leaving the file system intact. Quick 

Erase only works on FAT16 or FAT32 file systems. Media formatted using 

other file systems will fail, leaving the data intact. Works in Asynchronous 

Mode, meaning media may be removed once erased and more may be 

inserted later.

NOTE:

 NEVER remove a device while the LED is blinking.

6.5. Full Erase

Erases all content on target media completely by overwriting all blocks with 

zeros, leaving the media unformatted when complete. Works in Asynchro-

nous Mode, meaning media may be removed once erased and more may be 

inserted later.

NOTE:

 NEVER remove a device while the LED is blinking.

6.6. DoD Erase

Performs a 3-pass sanitization of all media blocks compliant with DoD 

5220.22-M standards.

6.7. System Update

Performs a firmware update to the unit. Update procedure details to be 

released with the update itself. Briefly, insert a media into the device contain-

ing the binary firmware image, then press OK. When the process is complete, 

turn the unit completely off, wait five seconds, then turn the unit back on.

Summary of Contents for UDFH7

Page 1: ...ng properly please have your product information ready and contact Addonics Technical Support at Hours 8 30 am 6 00 pm PST Phone 408 453 6212 Email http www addonics com support query www addonics com...

Page 2: ...www addonics com Technical Support M F 8 30am 6 00pm PST Phone 408 453 6212 Email www addonics com support query Unpacking and Overview Power Cord US Version Shown...

Page 3: ...ed Using the Duplicator with Adapters not supplied by Addonics is not supported or recommended Duplicating source media encrypted using the Addonics Cipher family of products can be done without using...

Page 4: ...blink If a target device is suitable the green LED will continue to blink and the copy process will begin immediately When a target is finished the green LED will glow to indicate the copy succeeded...

Page 5: ...the LED is blinking 5 Information The Information function is actually a sub menu with two functions 5 1 USB Info Pressing OK for USB info will begin with a port number beginning with 1 which is the S...

Page 6: ...a media is counted as a FAIL Expressed as a percentage of the tested area The Default setting is 0 Media Check uses Asynchronous Mode meaning devices may be removed once tested and new media may be in...

Page 7: ...ng operations that use Asynchronous Mode this setting determines the delay after all media have been removed before confirming that an operation is complete Once that delay has been expired the operat...

Page 8: ...nes the delay in seconds between the Copy and Compare func tions during Main Menu function 3 Copy Compare Default is 3 seconds 7 9 Language Sets the language used by the firmware s LCD display Choices...