Addonics Technologies RT3DAHEU3 User Manual Download Page 3

3

4

www.addonics.com

Technical Support (M-F 8:30am - 6:00pm PST)   

Phone: 408-453-6212 

Email: www.addonics.com/support/query/

Default factory DIP Switch setting:

SW1 – RAID Setting DIP Switch

BZS –   Error buzzer function

EZ   –   Automatic rebuilding to spare drive (one of the drives on the raid is set as a  

 

spare). If EZ is ENABLED anda drive failure occurs, the spare will    

 

automatically act as a drive replacement and rebuilding will automatically  

 start.

M2  –   RAID mode 2

M1  –   RAID mode 1

M0  –   RAID mode 0

1. 

Error buzzer function is ENABLED (BZS) when dip switch is in OFF position

2. 

Auto-rebuilding to spare drive is DISABLED (EZ)

3. 

Individual drive mode is ENABLED (M0~M2)

Note: 

When the default factory RAID setting is used, independent drive configuration 

and optical drive are supported only when connecting to controllers with Silicon 

Image  Sil3124,  Sil3132  chip  set  or  controllers  that  are  Port  Multiplier  (PM) 

compatible. Simultaneous DVD writing was tested using the Nero Burning Rom.

LED Pin Header

J1 – Drive Activity LED

P5  –   Activity LED for eSATA host port lights up when it is connected to a           

 

SATA controller card.

P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is 

connected and blinks when there’s drive activity.

J3 – Error LED

P5  –   error LED for eSATA host port

P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5

J3 

  

 

    J1

Error LED    

 Activity LED

P5  P0  P1  P2  P3  P4

P5  P0  P1  P2  P3  P4

1      2      3      4      5

SW1

BZS  EZ    M2   M1   M0

OFF

OFF

OFF

OFF

OFF

Setting or Modifying the RAID Mode Using the JMicron 

HW RAID Manager Utility Program:

1. 

For Windows users, install the JMicron HW RAID Manager located on the  

 

SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This  

 

manager can be use to create and monitor the status of the RAID volume.

 

It is recommended to use the default factory RAID DIP switch setting when  

 

using the JMicron HW RAID Manager.

2. 

Modify the RAID mode on the 5-port HPM-XA using DIP switch

 

Recommended to be used on operating system without JMicron HW RAID  

 

Manager support like Linux, Mac & Solaris. Windows users can also use the  

 

procedure below.

Note: Steps A to D need to be performed each time the raid mode is modified.

 

a. 

Set the DIP switch to factory default setting. 

 

 

b. 

Press the RAID setting button with a ball point pen.

 

c. 

While pressing the RAID setting button turn on the system power  

 

 

where the HPM is connected. The buzzer will sound while holding the  

 

 

RAID setting button. Release it after at least 5 seconds for hardware  

 

 

initialization. A single beep will be heard to indicate initialization is  

 

 

completed. The above steps act as a reset.

 

d. 

Power off the system power.

1      2      3      4      5

SW1

BZS  EZ    M2   M1   M0

OFF

OFF

OFF

OFF

OFF

Reviews: