Setting or Modifying the RAID Mode Using the JMicron 

HW RAID Manager Utility Program:

1. 

For Windows users, install the JMicron HW RAID Manager located on the  

 

SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This  

 

manager can be use to create and monitor the status of the RAID volume.

 

It is recommended to use the default factory RAID DIP switch setting when  

 

using the JMicron HW RAID Manager.

2. 

Modify the RAID mode on the 5-port HPM-XA using DIP switch

 

Recommended to be used on operating system without JMicron HW RAID  

 

Manager support like Linux, Mac & Solaris. Windows users can also use the  

 

procedure below.

Note: Steps A to D need to be performed each time the raid mode is modified.

 

a. 

Set the DIP switch to factory default setting. 

 

 

b. 

Press the RAID setting button with a ball point pen.

 

c. 

While pressing the RAID setting button turn on the system power  

 

 

where the HPM is connected. The buzzer will sound while holding the  

 

 

RAID setting button. Release it after at least 5 seconds for hardware  

 

 

initialization. A single beep will be heard to indicate initialization is  

 

 

completed. The above steps act as a reset.

 

d. 

Power off the system power.

1      2      3      4      5

SW1

BZS  EZ    M2   M1   M0

OFF

OFF

OFF

OFF

OFF

Summary of Contents for RT3DA5HP

Page 1: ...upport If you need any assistance to get your unit functioning properly please have your product information ready and contact Addonics Technical Support at Hours 8 30 am 6 00 pm PST Phone 408 453 621...

Page 2: ...m This is to help in identifying which drives connect to which ports for easier troubleshooting Connecting the power cable and RAID Tower III to the computer a Connect the power cord provided from the...

Page 3: ...de Raid Mode 1 2 3 4 5 Individual Drive Factory Default OFF OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON ON OFF ON ON OFF OFF ON OFF OFF OFF ON ON 0 1 and 10 3 5...

Page 4: ...ual drive mode is ENABLED M0 M2 Note When the default factory RAID setting is used independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Imag...

Page 5: ...ort HPM XA using DIP switch Recommended to be used on operating system without JMicron HW RAID Manager support like Linux Mac Solaris Windows users can also use the procedure below Note Steps A to D n...

Page 6: ...NABLED EZ function is DISABLED 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 RAID 0 Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 Clone Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 RAID 1 RAID 10 Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 Large...

Page 7: ...s connected to an eSATA host controller card on the RAID BIOS the raid array will display as Addonics H W RAID0 if setup as a RAID0 array k If booted into Windows in Disk Drives under Device Manager t...

Page 8: ...come the spare drive For a 3 drive RAID5 with spare Drives connected to SATA ports 1 3 belong to the active RAID5 array and drive connected to port 4 is the spare For a 4 drive RAID10 with spare Drive...

Reviews: