Addi-Data MSX-E3711 Quick Installation Download Page 7

www.addi-data.com

The following actions are possible:

IP Address: 

Change the IP address of the MSX-E system in order to adapt it to your 

 

  corporate network, for example.

Web Interface: 

Access the web interface of your MSX-E system and change the 

 

  configuration.

Save General Configuration: 

Save the general configuration of the MSX-E system 

 

  (including, for example, the network configuration), i.e. all the settings defined on the 

 

  web interface apart from the I/O configuration.

Load General Configuration: 

Load a file containing the general configuration of the 

 

  MSX-E system.

Save I/O Configuration: 

Save all function-specific settings defined on the web 

 

  interface under “I/O Configuration”.

Load I/O Configuration: 

Load a function-specific configuration.

Transducer Database: 

Edit the user’s transducer database, that is, for example, change

 

  transducer features and add new transducers. The MSX-E database must contain the 

 

  transducers that will be connected to the MSX-E system in order for the system to 

 

  detect them.

Firmware Update: 

Update the firmware of the MSX-E system. The required 

 

  firmware file is available on request. The file name corresponds to the firmware version.

Transducer Calibration: 

Calibrate transducers connected to one or more channels.

Transducer Diagnosis: 

Test transducers for errors (short-circuit, open load).

Transducer Monitoring: 

Select the channels to be acquired and start the acquisition 

 

  with monitoring. For each channel, each acquired value is immediately displayed in a 

 

  diagram.

NOTICE!

Depending on the Ethernet system, a different number of buttons  

and accordingly, different types of actions are available.

Summary of Contents for MSX-E3711

Page 1: ...usiness Center Airport Boulevard B210 77836 Rheinmünster Germany Phone 49 7229 1847 0 Fax 49 7229 1847 222 info addi data com www addi data com 02 07 01 2016 QUICK INSTALLATION MSX E3711 Ethernet system for length measurement ...

Page 2: ...system D Connect the Ethernet system to the power source using a power supply cable e g CMX 20 E Check the status of the Ethernet system by means of the LED display Power On lights green Power supply is OK Port 0 ACT Link flashes yellow Ethernet cable is connected to Port 0 Port 1 ACT Link flashes yellow Ethernet cable is connected to Port 1 Status lights green Ethernet system is ready for operati...

Page 3: ...D0 RD1 white 3 TD0 TD1 orange 4 RD0 RD1 blue Trigger Synchro Trig Sync In Trig Sync Out Cable purple Pin No Male connector 5 pin M12 Female connector 5 pin M12 Lead colour Lead pair 1 Trigger input Trigger input blue 1 2 Trigger input Trigger input white 3 Synchro input Synchro output red 2 4 Synchro input Synchro output black 5 GND GND Pin assignment ...

Page 4: ...Transducer inputs Half Bridge LVDT Mahr Pin No Female connector 5 pin M18 Female connector 5 pin M18 Female connector 5 pin M18 1 OSC OSC OSC 2 GND OSC Voltage input transducer n 3 Transducer signal not connected Current input transducer n 4 not connected Transducer signal GND 5 OSC GND OSC Mahr version compatibility code M To avoid any confusion a red ring is placed on the cable connector in addi...

Page 5: ...couple CJC Cold junction compensation RTD Resistance temperature detector EXC Current source excitation OPT MSX E TC The Pt1000 sensor for the cold junction compensation CJC is integrated in the supplied connector SC M12 5 TC Incremental counter input Pin No Female connector 12 pin M23 Pin No Female connector 12 pin M23 1 B 7 D 2 Power supply 24 V or 5 V 8 B 3 C 9 D 4 C 10 GND 5 A 11 GND 6 A 12 Po...

Page 6: ...ture After scanning all connected MSX E systems are listed in the ConfigTools Explorer on the left When you click on the name of one of these systems corresponding product information such as IP address MAC address and firmware version will be shown on the right side of the main window To scan the connected systems once again for example after connecting another MSX E system you have to click on t...

Page 7: ... a function specific configuration Transducer Database Edit the user s transducer database that is for example change transducer features and add new transducers The MSX E database must contain the transducers that will be connected to the MSX E system in order for the system to detect them Firmware Update Update the firmware of the MSX E system The required firmware file is available on request T...

Page 8: ...he MSX E system From the web interface of your MSX E system you can access the system quickly and manage your functions conveniently without programming To open the web interface of your MSX E system proceed as follows Open a web browser such as Mozilla Firefox Internet Explorer etc and enter the following address http IP address of the Ethernet system A login window is displayed Enter mxadmin as ...

Reviews: