02.04 - 01/2016

QUICK 

INSTALLATION

MSX-E1731 

Ethernet multifunction counter system 

Summary of Contents for MSX-E1731

Page 1: ...Business Center Airport Boulevard B210 77836 Rheinmünster Germany Phone 49 7229 1847 0 Fax 49 7229 1847 222 info addi data com www addi data com 02 04 01 2016 QUICK INSTALLATION MSX E1731 Ethernet multifunction counter system ...

Page 2: ...ower supply cable e g CMX 20 E Check the status of the Ethernet system by means of the LED display Power On lights green Power supply is OK Port 0 ACT Link flashes yellow Ethernet cable is connected to Port 0 Port 1 ACT Link flashes yellow Ethernet cable is connected to Port 1 Status lights green Ethernet system is ready for operation lights yellow Ethernet system is booting lights flashes red Err...

Page 3: ...D0 RD1 white 3 TD0 TD1 orange 4 RD0 RD1 blue Trigger Synchro Trig Sync In Trig Sync Out Cable purple Pin No Male connector 5 pin M12 Female connector 5 pin M12 Lead colour Lead pair 1 Trigger input Trigger input blue 1 2 Trigger input Trigger input white 3 Synchro input Synchro output red 2 4 Synchro input Synchro output black 5 GND GND Pin assignment ...

Page 4: ... V white 3 GND GND blue 4 GND GND black 5 not connected not connected grey Digital I O Pin No Female connector 5 pin M12 Cable black Lead colour 1 24 V output brown 2 Digital I O 2n 1 white 3 GND blue 4 Digital I O 2n black 5 not connected grey Please note that the female connector n is dual wired and that the digital I Os are determined via 2n 1 or 2n with 0 n 7 ...

Page 5: ... 4 2 x 7 Digital I O 14 EnDat 2 2 counter inputs Pin No Female connector 8 pin M12 Polarity Function Signal name 2 8 Voltage supply 24 V or 5 V Output 5 V 24 V can be set via jumper condition upon delivery 5 V Supply for EnDat 2 2 encoder V 5 1 GND GND GND 3 A Input RS422 TTL Data line DATA_0 _x 4 A DATA_0 _x 7 B Input RS422 TTL Clock line CLK_0 _x 6 B CLK_0 _x ...

Page 6: ...ture After scanning all connected MSX E systems are listed in the ConfigTools Explorer on the left When you click on the name of one of these systems corresponding product information such as IP address MAC address and firmware version will be shown on the right side of the main window To scan the connected systems once again for example after connecting another MSX E system you have to click on t...

Page 7: ... a function specific configuration Transducer Database Edit the user s transducer database that is for example change transducer features and add new transducers The MSX E database must contain the transducers that will be connected to the MSX E system in order for the system to detect them Firmware Update Update the firmware of the MSX E system The required firmware file is available on request T...

Page 8: ...he MSX E system From the web interface of your MSX E system you can access the system quickly and manage your functions conveniently without programming To open the web interface of your MSX E system proceed as follows Open a web browser such as Mozilla Firefox Internet Explorer etc and enter the following address http IP address of the Ethernet system A login window is displayed Enter mxadmin as ...