Connecting the peripheral
APCI-3701
36
8.2.3
Connection of Mahr transducers
The pin assignment for Mahr transducers of the product range P2xxx-M (e.g.:
P2004-M) differs from the pin assignment for standard half-bridge transducers
(e.g. GT21 of Tesa).
Should you want to connect a Mahr transducer to the Box PX3701-HB-x with the
Mahr assignment (Designation M), an adapter between the transducer and the
flange socket of the connection box is necessary.
The Mahr transducers are also available with a Tesa compliant assignment
(Designation T; e.g. P2004-T). This version can be directly connected to the
connection box.
i
IMPORTANT!
Before ordering a Mahr transducer, you have to consider the different types
of the 5-pin assignment.
Table 8-1: Compliance of the Mahr transducers
Transducer pin
number
TESA-compliant
assignment
MAHR assignment
1 OSC+
OSC+
2
GND
Not assigned
3
Output signal
Output signal
4
Not assigned
GND
5 OSC-
OSC-
Remark:
Pin 2 and 4 are inverted.