Performing upgrades

The AdderView PRO unit is fully upgradeable via flash upgrade. Such upgrades 
require a Windows-based computer system to be linked via the 

OPTIONS

 port. 

Items required to perform an upgrade 

•  Optional upgrade cable (see 

Appendix 2

 for pin-out specifications).

•  A Windows-based upgrade computer with an RS232 serial port.
•  The latest version of the KVM Firmware Uploader and firmware files for 

the AdderView PRO unit - available from the 

Technical Support > Updates

 

section of the Adder Technology website (

www.adder.com

). 

To use the KVM Firmware Uploader utility

1 - Obtain and run the KVM Firmware Uploader.

  Download the latest AdderView PRO unit KVM Firmware Uploader from 

the Adder Technology website and install it on a Windows-based upgrade 
computer that will be connected to the AdderView PRO unit. The files 
are supplied as a compressed ZIP file. Decompress the ZIP file with an 
appropriate tool such as WinZip (www.winzip.com) and copy all contained 
files to the same folder on the upgrade computer. 

2 - Power off the AdderView PRO unit

  Remove the power supply plug from the rear panel of the unit. 

3 - Connect the upgrade computer to the AdderView PRO unit

  Connect the serial port of the upgrade computer to the 

OPTIONS

 port on the 

rear panel of the unit using the optional upgrade cable. 

4 - Invoke upgrade mode

   While powering on or when already powered: Press and hold the 

COMPUTER and MODE buttons (for up to ten seconds) until the numeric 
indicator shows ‘ ’.  

5 - Run the KVM Firmware Uploader utility

  From that folder, select the KVMUploader icon to run the upgrade utility. 

The KVM Firmware Uploader dialog will be displayed:

6 - Query the AdderView PRO unit

  Click the 

Query Unit

 button to confirm that communication is possible with 

the AdderView PRO unit and to establish its firmware details. If successful, 
the ‘Unit connected’ field should show the name of the AdderView PRO unit 
and the current firmware will also be listed.

  If the application cannot contact the AdderView PRO unit, re-check the 

connection cable and click the 

Advanced...

 button to check that the correct 

serial port is being used. Change the serial port within the 

Advanced...

 

section, if necessary.  

continued

  There is no need to adjust the computer’s serial port 

settings as the application will do this automatically.

4

5V

2A

USER

CONS

OLE

OPTIO

NS

Summary of Contents for AVPRO-DVI

Page 1: ...AdderView PRO User Guide COMPUTER KVM SPK USB1 USB2 MODE www adder com AV4PRO DVI AV4PRO DVI DUAL AV4PRO DVI TRIPLE AV4PRO DVI QUAD...

Page 2: ...ion Using the configuration menu 13 General configuration 14 Changing hotkeys 14 Mouse switching 14 OPTIONS port speed 14 OPTIONS port channel control behaviour 14 Switching mode 15 Miscellaneous func...

Page 3: ...units feature True Emulation which ensures that the full characteristics of the connected keyboard and mouse are passed to every system Digital and analogue video The AdderView PRO units use DVI I Int...

Page 4: ...ecessary signals states and processes Therefore manufacturers have previously relied upon a fixed keyboard and mouse profile that is declared to each computer regardless of the actual connected device...

Page 5: ...two USB devices to these connectors These ports are switched in an enumerated manner see What is True Emulation COMPUTER KVM SPK USB1 USB2 MODE www adder com Indicators The four indicators KVM SPK US...

Page 6: ...number VSC40 Power adapter 12 5W or 20W and country specific power lead Two 19 rack mount brackets and four screws Part number RMK3 Combined dual link DVI D and USB USB type A to B cable Part numbers...

Page 7: ...ackets plus four screws allow the unit to be secured within a standard rack slot Note Both the AdderView PRO unit and its power supply generate heat when in operation and will become warm to the touch...

Page 8: ...o Where required connect the lead from your speakers to the audio socket Note The unit s True Emulation feature will read the full characteristics of the keyboard and mouse and will present those to e...

Page 9: ...ng computers to the AdderView PRO unit Part numbers VSCD3 for a 2m cable and VSCD4 for a 5m cable From the USB port on the computer From the video port on the computer From the speaker port on the com...

Page 10: ...e them or place them in locations where air cannot circulate to cool the equipment Do not operate the equipment in ambient temperatures exceeding 40 degrees Centigrade Do not place the products in con...

Page 11: ...red are determined by the current setting of the switching mode Control by channel select input lines Where the external control is via the four channel select input lines of the OPTIONS port see pin...

Page 12: ...to switch up to eight video heads simultaneously Whenever an AdderView PRO channel is switched it sends an RS232 command out on its serial interface marked OPTIONS on the rear panel An AdderView PRO w...

Page 13: ...nvoke this option the unit will only use the EDID information that it has already stored and pass this on to the connected computers To revert to interrogating the video display use the F 2 function d...

Page 14: ...Functions menu Show current firmware version Refresh EDID information from the connected video display default Use the stored EDID at startup do not interrogate the video display Reset configuration t...

Page 15: ...changes OPTIONS port channel control behaviour You can determine how the OPTIONS port responds to channel control inputs To define the OPTIONS port behaviour 1 Enter the Configuration menu 2 Press to...

Page 16: ...he Configuration menu 2 Press to enter the Functions menu 3 Press and then 4 Press and then to exit the menu and save changes To use the stored EDID information at the power up When you engage this mo...

Page 17: ...the power supply plug from the rear panel of the unit 3 Connect the upgrade computer to the AdderView PRO unit Connect the serial port of the upgrade computer to the OPTIONS port on the rear panel of...

Page 18: ...dialog IMPORTANT Check that the Intended Target Units field matches the Unit Connected field If these fields do not match then you may have an incorrect upgrade file check with Adder Technology Ltd b...

Page 19: ...the keyboard video and mouse Will switch only the speakers Will switch only USB peripheral 1 Will switch only USB peripheral 2 Note If an indicator flashes it signifies that the respective peripheral...

Page 20: ...o the AdderView PRO unit that you wish to control it rather than the computer However if these particular hotkeys clash with another device or program you can change them to a different combination wi...

Page 21: ...reached release the middle button When using this method of switching The computer channels that are visited depend upon the configuration menu setting see note The ports KVM audio and or USB that ar...

Page 22: ...case sensitive and can be any combination of key strokes including the function keys but excluding the Num Lock Caps Lock Scroll Lock and keys If your keyboard has special media keys these also cannot...

Page 23: ...uter ranging from 2 seconds to 5 minutes To prepare the autoscan period choose and then to within the configuration menu see right To start autoscanning mode press on the keyboard To select an autosca...

Page 24: ...statements Getting assistance If you are still experiencing problems after checking the list of solutions in the Troubleshooting section then we provide a number of other solutions Adder Technology w...

Page 25: ...BM VGA 720 x 400p at 88Hz IBM XGA2 640 x 480p at 60Hz IBM VGA 640 x 480p at 67Hz Apple Mac II 640 x 480p at 72Hz VESA 640 x 480p at 75Hz VESA 800 x 600p at 56Hz VESA 800 x 600p at 60Hz VESA 800 x 600p...

Page 26: ...both types of connector Serial remote control and flash upgrade cable 8p8c 8p8c connector D Type female 9 way Multi head synchronisation cable 8p8c MASTER end 8p8c connector SLAVE end 8p8c connector 6...

Page 27: ...PRO unit make sure the total ampere rating of the devices plugged into the extension cord does not exceed the cord s ampere rating Also make sure that the total ampere rating of all the devices plugge...

Page 28: ...is connected d Consult the supplier or an experienced radio TV technician for help FCC Compliance Statement United States This equipment generates uses and can radiate radio frequency energy and if n...

Page 29: ...Way Bar Hill Cambridge CB23 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation 350R Merrimac Street Newburyport MA 01950 United States of America Tel 1 888 932 3337 Fax 1 8...

Page 30: ...unit 20 M Mounting 6 Mouse connection 7 Multiple units synchronising 11 Multiple video head connections 11 O Operation 17 Options port 4 P Parts supplied and extra 5 Password setting entering 20 Perip...

Reviews: