background image

Multi-Viewer Switch API

 

 

 

 

MAN-000023                                                                                                                               Page 2 

 

Introduction 

This guide explains how to use RS-232 to remotely control an Adder Multi-Viewer switch (AVS-1124, 
CCS-MV4224). 
 
To control a switch using RS232, the user needs to connect a controlling device to the 

switch’s RCU port. 

The controlling device can be a PC or any custom device with RS-232 capability. 
 
Remote controlling means performing actions that users could otherwise do only using the front panel or 
hotkeys, including: 

 

Switching channels 

 

Audio hold 

 

Selecting a screen preset layout 

 

Installation 

This procedure shows how to connect a switch to a remote-control device. A suitable RS232 cable will be 
required with an RJ12 connector to plug into the RCU port with the pinout shown below: 
 

 

Pinout for the RDU port: 

• 

Pin 1: 5V 

• 

Pin 2: Not connected 

• 

Pin 3: Not Connected 

• 

Pin 4: GND 

• 

Pin 5: RX 

• 

Pin 6: TX 

 
Few modern PCs have an RS232 port, so it may be necessary to use a USB or Ethernet adapter. 
 

Operation 

Configuring example using the PuTTY open-source serial console utility. This procedure demonstrates 
how to switch channels via RS-232 using a remote control Windows PC. 
 

Pre-configuration 

1.  Install PuTTY on the remote computer. 
2.  Connect 

a serial cable from the PC’s USB port to the switch’s RCU port. 

3.  Run the PuTTY utility. 
4.  Configure the Serial, Terminal and Session settings, as per figures 1 to 3 

Reviews: