Chapter 3: Provisioning
September 25, 2006
3-16
LTPE-UM-3159-02
Figure 3-9. LOS*, PFO* and LOSW* Alarm Reporting Screen
Shelf Alarms Menu
In the Config menu, press H to display the Shelf Alarms menu (
Figure 3-10
). This menu allows you to enable,
disable, and set the severity of the loss of shelf power, HDSL/G.SHDSL lines down, and loss of external clock alarm.
The Config menu also allows you to configure how each of the alarm relays respond to an ACO (Alarm Cut-Off). The
ACO can be activated from the EMU-830 front panel pushbutton or by connecting to ground the EXT (external) ACO
pin on the EMS-83x shelf's alarm connector. Selecting Enable (ENA) causes the associated alarm relay to be retired
(common contact connected to normally closed contact) when an ACO is received.
Figure 3-10. Shelf Alarms Menu
Note:
To select the Shelf Alarms menu for a different shelf, press ESC and then Q to return to the Network
screen, select a shelf with the
Ç
and
È
arrow keys, and press L to open the Main menu screen for that
shelf. Press C and then H to display the Shelf Alarms menu for the selected shelf.
Summary of Contents for WorldDSL EMU-830
Page 1: ...WorldDSLTM Exchange Office Management Unit EMU 830 User Manual Document Number LTPE UM 3159 02...
Page 8: ...List of Tables September 25 2006 viii LTPE UM 3159 02...
Page 22: ...Chapter 1 Overview September 25 2006 1 12 LTPE UM 3159 02...
Page 64: ...Chapter 3 Provisioning September 25 2006 3 32 LTPE UM 3159 02...
Page 66: ...Appendix A Specifications September 25 2006 A 2 LTPE UM 3159 02...
Page 68: ...Appendix B Product Support September 25 2006 B 2 LTPE UM 3159 02...
Page 72: ...Glossary September 25 2006 GL 4 LTPE UM 3159 02...